akkuteam VAS6558A/38A Operation Manual

High voltage test adapter set vas 6558a/38a

Advertisement

Quick Links

Operation Manual
H i g h V o l t a g e T e s t A d a p t e r S e t VA S 6 5 5 8 A /3 8 A
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VAS6558A/38A and is the answer not in the manual?

Questions and answers

Summary of Contents for akkuteam VAS6558A/38A

  • Page 1 Operation Manual H i g h V o l t a g e T e s t A d a p t e r S e t VA S 6 5 5 8 A /3 8 A...
  • Page 2: Imprint

    All rights reserved. All texts, images and graphics are subject to copyright and other laws protecting intellectual property. Copyright 2023 Akkuteam Energietechnik GmbH. Image sources Warning signs, prohibition, mandatory and standard symbols come from public sources such as generally accessible areas on the Internet. CAD product images and product photos come from the...
  • Page 3: Table Of Contents

    Contents Contents IMPRINT CONTENTS INTRODUCTION Preliminary remarks Validity of the declaration of conformity Manufacturer information SECURITY Warning levels important safety instructions Intended Use Requirements for the target group Obligations of the operator PRODUCT DESCRIPTION Scope of delivery Construction Symbols and connections Technical data SERVICE Installation...
  • Page 4: Introduction

    Manufacturer information Akkuteam Energietechnik GmbH akkuteam is a specialist provider of battery and backup power technology. We ensure grid- independent electrical energy supply in mobile and stationary areas. We are an owner-managed, medium-sized family business. Our GmbH can now look back on 25 years of company history, which has always been characterized by strong growth.
  • Page 5: Security

    EN | Security Security This safety chapter informs you about the following: • Warning levels included in this user manual • Important safety information about the product, • Intended use of the product, • Requirements for the target group. These operating instructions are exclusively valid for the following product: Item number: ASE 405 478 01 000 Designation:...
  • Page 6: Important Safety Instructions

    EN | Security important safety instructions This chapter informs you about the safety instructions that must be observed when handling the product. DANGER Danger to life due to electrical voltage! The electrical voltage in other systems is life-threatening and will result in death from electric shock! •...
  • Page 7: Intended Use

    EN | Security Intended Use Use the product exclusively in accordance with these operating instructions, otherwise the protection against electrical hazards provided for in the product is no longer guaranteed. The product is used to adapt the high-voltage measuring module VAS 6558/VAS 6558A to the vehicle-side plug connection specified by the vehicle manufacturer in the guided troubleshooting.
  • Page 8: Product Description

    EN | Product description Product description Scope of delivery Immediately check the condition and completeness of the scope of delivery. If there are any defects, contact the manufacturer immediately. (1) High Voltage Test Adapter Set VAS 6558A/ 38A (2) Test Adapter VAS 6558A/38A-2 Adapter A (3) Test Adapter VAS 6558A/38A-2 Adapter B (4) USB stick with operating instructions (5) Storage case...
  • Page 9: Construction

    EN | Product description Construction Structure of the product: (1) Connection plug HV test adapter (2) Connection socket HV test adapter (3) Test sockets HV test adapter (see circuit diagram on housing) (4) Connection socket for test adapter B (5) Test sockets test adapter B (6) Connection plug test adapter A (7) Test sockets test adapter A...
  • Page 10: Symbols And Connections

    EN | Product description Symbols and connections The following symbols are shown on the product: Symbol Meaning General warning signs Electrical hazard! Read the operating instructions! The serial number, together with the manufacturer part number, is used to identify the product.
  • Page 11 EN | Product description The product has the following connections: Connection function Ground socket Plus socket Minus socket Test socket 1 Test socket 2 Test socket 3...
  • Page 12: Technical Data

    EN | Product description Technical data Rated data Values Manufacturer number 22104189 Maximum rated voltage 1000 V/DC Maximum rated current 10 A Protection class II / double insulated Weight ~ 2279 g Dimensions L/H/W ~ 400 mm/200 mm/300 mm Cable length 850 mm Environmental Operation...
  • Page 13: Service

    EN | Service Service This chapter informs you about the following activities: • Installation, • loosening the plug connection, • Cleaning, • storage and transport, • Disposal, • Maintenance. WARNING Danger to life due to electrical voltage! The electrical voltage in high-voltage systems is life-threatening and can lead to death from electric shock! •...
  • Page 14: Installation

    EN | Service Installation Measurement Follow the safety instructions. Connect the connection socket to the removed plug of the connection to be tested. Lock the connection. Connect the high-voltage measuring module to the high-voltage test adapter according to the guided troubleshooting procedure. Use the test sockets in the red connection area.
  • Page 15: Loosen The Plug Connections

    EN | Service Loosen the plug connections WARNING Danger of explosion! Components of the product can cause sparks and arcs. • Never disconnect plug connections of the high-voltage cables under load! • Do not use the product in potentially explosive areas! •...
  • Page 16: Cleaning

    EN | Service Cleaning DANGER Danger to life due to electrical voltage! The electrical voltage in high-voltage systems is life-threatening and will lead to death from electric shock! • Disconnect the product from all power sources before cleaning the product! Pay attention to the safety instructions! The product may only be cleaned with a dry cloth.
  • Page 17: Help

    Customer service If you have general questions about usage and functionality, please contact the following support: Akkuteam Energietechnik GmbH Theodor-Heuss-Strasse 4 37412 Herzberg am Harz Telephone: +49 (0) 5521 9981-0 Fax: +49 (0) 5521 9981-11 service@akkuteam.de...
  • Page 18 Volkswagen Aktiengesellschaft Akkuteam Energietechnik GmbH Group After Sales – Group Service. Theodor-Heuss-Strasse 4 Literature and systems 37412 Herzberg am Harz Workshop equipment Telephone: +49 (0) 5521 9981-0 Mailbox 011/4915 Fax: +49 (0) 5521 9981-11 38442 Wolfsburg service@akkuteam.de For internal use only www.akkuteam.de...

This manual is also suitable for:

Vas6558a/38a-1Vas6558a/38a-2

Table of Contents