Do you have a question about the Bell Fruit Games Scorpion 6 and is the answer not in the manual?
Questions and answers
Brian Owens
April 6, 2025
Nv 10 won't connect
1 comments:
Mr. Anderson
April 6, 2025
The Novomatic Bell Fruit Games Scorpion 6 may not connect due to one or more of the following reasons:
1. Peripheral Not Paired: Error codes such as COINMECNPA1 (coin mechanism not paired), NOTEVANPA2 (note validator not paired), and HOPPERNPA3 (hopper not paired) indicate that the peripheral devices are not correctly paired with the machine.
2. Incorrect Loom Connection: The loom (cable) may not be connected properly. For example, it should have specific wire colors like red, black, and white or yellow, depending on the device.
3. Incorrect DIL Switch Settings: DIL switch 4 on bank DS2 must be ON, and switches 6, 7, and 8 on DS2 must also be ON. All DIL switches on DS1 must be OFF.
4. Improper Pairing Procedure: The correct pairing procedure for devices like the Vega bezel or NV11 must be followed, including timing for button presses and LED checks.
5. RAM Error or Corruption: If the machine has a RAM error or has been replaced, devices may need to be re-enabled or re-paired, as previous settings can be lost.
6. Validator Rejected Notes: If a note is rejected with no message, the validator is rejecting it. If no validator is fitted, the test will not display notes.
Each of these issues can prevent the machine from connecting or functioning properly.
This answer is automatically generated
Related Manuals for Novomatic Bell Fruit Games Scorpion 6
Need help?
Do you have a question about the Bell Fruit Games Scorpion 6 and is the answer not in the manual?
Questions and answers
Nv 10 won't connect
The Novomatic Bell Fruit Games Scorpion 6 may not connect due to one or more of the following reasons:
1. Peripheral Not Paired: Error codes such as COINMECNPA1 (coin mechanism not paired), NOTEVANPA2 (note validator not paired), and HOPPERNPA3 (hopper not paired) indicate that the peripheral devices are not correctly paired with the machine.
2. Incorrect Loom Connection: The loom (cable) may not be connected properly. For example, it should have specific wire colors like red, black, and white or yellow, depending on the device.
3. Incorrect DIL Switch Settings: DIL switch 4 on bank DS2 must be ON, and switches 6, 7, and 8 on DS2 must also be ON. All DIL switches on DS1 must be OFF.
4. Improper Pairing Procedure: The correct pairing procedure for devices like the Vega bezel or NV11 must be followed, including timing for button presses and LED checks.
5. RAM Error or Corruption: If the machine has a RAM error or has been replaced, devices may need to be re-enabled or re-paired, as previous settings can be lost.
6. Validator Rejected Notes: If a note is rejected with no message, the validator is rejecting it. If no validator is fitted, the test will not display notes.
Each of these issues can prevent the machine from connecting or functioning properly.
This answer is automatically generated