Advertisement

Quick Links

Manual
DVP050
DVP100
DVP170
Visit www.duratech.be for other available languages
06-03-23
Pro

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the welldana VISION Pro DVP050 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Duratech welldana VISION Pro DVP050

  • Page 1 Manual DVP050 DVP100 DVP170 Visit www.duratech.be for other available languages 06-03-23...
  • Page 3: Table Of Contents

    Table of contents Technical specifications Page 4 Remarks Page 5-6 Box contents Page 7 Page 10-11 Installation instructions Installation specialties Page 12-13 Wiring instructions setup 1 Page 14-15 Wiring instructions setup 2 Page 16-17 Page 18-19 Wiring remarks Synchronizing Page 20 Color programs Page 21 Troubleshooting...
  • Page 4: Technical Specifications

    Technical specifications Luminous Lamp Type Description Voltage Power Color temp flux* All colours and DVP050-RGBW 10-14 VAC 33 W n.a. 1200 lm Tunable white All colours and DVP100-RGBW 10-14 VAC 85 W n.a. 3500 lm Tunable white All colours and DVP170-RGBW 10-14 VAC 180 W...
  • Page 5: Remarks

    Remarks Water conditions Prevent damage to your pool lamps and wires due to unstable water conditions. Your local government may have enacted guidelines for your pool water conditions to apply by. If not we strongly advise the following parameter specifications to be applied: pH level 6,8 - 7,6 Free Chlorine...
  • Page 6 Installation/maintenance The luminaire is maintenance free If the luminaire needs to be replaced, it needs to be completely removed from the water If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid hazard VISION Pro Pool lamps must be completely submerged into water during operation.
  • Page 7: Box Contents

    Box contents 2m Cable** VISION Pro lamp Connection Kit* (50, 100 or 170 mm) Retrofit Kit Manual (only for 170mm models) Lamp type Connection kit Cable DVP050-RGBW 513-0480 ; 1 washer for fixnut ; blue cable gasket 1 mm DVP100-RGBW 513-0636 ;...
  • Page 8: Installation Instructions

    Installation instructions Installing faceplate Toolset ( not included ) Contact your local distributor for a toolset (513-0151) Lamp Face Plate...
  • Page 9 Installation instructions Installing connector DVP050-RGBW DVP100-RGBW DVP170-RGBW 2m Cable Washer Fix Nut Silicone Gasket Connector Installation: Page 10 & 11...
  • Page 10 Connector installation...
  • Page 12: Installation Specialties

    Installation specialties DVP050 & PZA-WG For installations with DVP050 & PZA-WG-S or PZA-WG-G: Please make sure to only use 1 silicone washer for the Fix nut Fix nut PZA-WG-G...
  • Page 13 DVP050 Removal tool When DVP050 needs to be removed from PZA-WG wall conduits, a special tool is needed (513-0491)* 1. Insert the tool over the lamp, straight into the wall conduit 2. Twist the tool counter clockwise the lamp should be snapped into the 3 hooks of the tool 3.
  • Page 14: Wiring Instructions Setup 1

    Wiring instructions Setup 1 For new installations Each lamp is connected to the transformer by a separate cable Pool Pool house SELECT CABLE SECTION & MAXIMUM LENGTH 2m cable included in lamp package Always use a toroïdal transformer Separate cable ( not included )
  • Page 15 SELECT CABLE SECTION & MAXIMUM LENGTH VA TRANSFORMER LAMP TYPE 1,5mm 2,5mm 4,0mm 6,0mm 10mm (12VAC)* 155m 43 VA DVP050-RGBW 111 VA DVP100-RGBW 234 VA DVP170-RGBW STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE * The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps.
  • Page 16 Wiring instructions Setup 2 For existing or other installations All lamps are connected to the transformer via 1 cable Pool Pool house SELECT CABLE SECTION & MAXIMUM LENGTH 2m cable included in lamp package Always use a toroïdal transformer Separate cable ( not included )
  • Page 17 SELECT CABLE SECTION & MAXIMUM LENGTH VA TRANSFORMER LAMP TYPE 2,5mm 4,0mm 6,0mm 10mm (12VAC) 155m DVP050-RGBW DVP100-RGBW DVP170-RGBW STABLE OPERATION OF THE POOL LIGHTS IS ONLY GUARANTEED WHEN THE INSTALLED CABLE CROSS SECTION MATCHES OR EXCEEDS THE ADVISED VALUES IN THE ABOVE TABLE...
  • Page 18: Wiring Remarks

    Wiring remarks LINK Controller or LINK Master For installations with Third party equipment such as frequency inverters and electric motors can generate excessive noise on the 230VAC / 400VAC power line. This noise might be injected into the adjacent 12VAC power line and disturb the power line communication towards the VISION Pro RGBW lights.
  • Page 19 Pool Pool house 12VAC to lamps (**) 230VAC Min. 50cm 230VAC / 400VAC to third party equipment (**) Do not mix 12VAC and 230VAC / 400VAC power line cables into the same cable trays...
  • Page 20: Synchronizing

    Synchronizing With LinkTouch + LINK Controller (PLP-REM or PLP-REM-350)* + LINK Master (DLM450 or DLM600) First make sure the LinkTouch is paired (see manual LinkTouch) Turn the lamps on and spin the color wheel on the LinkTouch until the lamps react. If the lamps do not react, turn them off and back on untill they react to the color wheel.
  • Page 21: Color Programs

    Color programs RGBW LAMPS DEEP BLUE SEA Saturated blue DAYLIGHT BLUE Light blue SUNSET Slow animation orange - red LOVE IS IN THE AIR FOREST SPRING Green THINK PINK Pink SUNSHINE Yellow JUNGLE BEACH Slow animation blue & green tints VOODOO Slow animation red &...
  • Page 22: Troubleshooting

    Troubleshooting PROBLEM SOLUTION The pool light is flickering 1. Switch the lamps ON and select Cold white color program 2. Remove the lamp from the water, unscrew the fix nut, pull back the gasket and the black cable jacket, so you can reach the brass contacts inside the connector block (do not remove the connector block) 3.
  • Page 23 Declaraction of Conformity Declarations of conformity covering this product are available for download from the House of Duratech website: www.duratech.be VISION Moonlight HEAT Hot Splash FLOW Inverter COVER Tube LINK Driver VISION Spectra HEAT Sun Spring FLOW Cartridge Filter COVER...
  • Page 24 Contact details Propulsion Systems bv Dooren 72 1785 Merchtem, Belgium Tel +32 2 461 02 53 www.duratech.be info@propulsionsystems.be We reserve the rights to change all or part of the contents of this document without prior notice...

This manual is also suitable for:

Welldana vision pro dvp100Welldana vision pro dvp170

Table of Contents