To the new owner of Wonder Axon®: Congratulations! We welcome you as the new owner of the Wonder® Axon equipment. Wonder® Axon is a top-quality Spanish equipment that is characterized by its safety, efficacy and ease of use. It is manufactured according to the latest advances in microelectronics and computer technology.
Page 4
2. INTRODUCTION 3. PRECAUTIONS 4. FIRST USE 5. SAFETY CONDITIONS OF THE WORK SPACE 6. INSTALLATION INSTRUCTIONS 7. PARTS OF THE GENERAL EQUIPMENT OF WONDER® AXON 8. CONSERVATION AND CARE. 9. TREATMENT 10. THE TREATMENT 11. PRE-SET PROGRAMS 12 - OPERATIONS WITH THE SOFTWARE 13.
60335-1: 2012, EN 62233: 2008, IEC 60335-1: 2010, we inform the users of our device of the following: 1. Wonder® and the services provided are not intended for use in the detection, monitoring or therapeutic treatment of any disease, ailment or vital physiological process. Although Wonder® can be used in treatments aimed at solving bone or muscle problems, loss of muscle tone, strengthening the pelvic floor, tendinitis, contracture, etc., it is not a strict medical device.
Page 6
WARNING It should only be supplied at a very low safety voltage corresponding to the marking on the 8.4Volt DC appliance. Do not expose to fire or high temperatures 45ºC. If the power cord is damaged, it should be replaced by the manufacturer, by its after-sales service or by similar qualified personnel with the fon to avoid a hazard.
Page 7
2. INTRODUCTION Wonder ® Axon is a device for aesthetic use that has been designed and manufactured to be used in treatments of bodybuilding, toning of the figure, muscle recovery and improvement of the general state of the body. Wonder® Axon has all the technological advances to carry out safe, effective, fast and comfortable treatments.
Page 8
If this equipment causes harmful interference in the reception of radio or television, which can be determined by turning the equipment on and off, the user is recommended to try to correct the problem with one or more of the following measures: Increase the separation between equipment and receiver.
Page 9
Handle, clean, and dispose of components and accessories that have come into contact with body fluids in accordance with national, local, and installation rules, regulations, and procedures. Explosion hazard if Wonder is used in the presence of a mixture of flammable anesthetics with air, oxygen or nitrous oxide.
Page 10
Humidity - WARNING! Use the device in a completely dry environment. Do not use Wonder ® in water or in a wet place (sauna, spas, swimming pools, etc.) or outdoors with high humidity. Users should carefully read this Manual, its precautionary measures and action protocols before operating Wonder®.
Wonder ® is grounded through the ground conductor on the power cord. This protective grounding is essential for safe operation. Ensure that the electrical output from the room where it will be used is properly grounded. Do not use flammable substances to clean any part of the Wonder system® 4. FIRST USE Follow the steps below for successful implementation of Wonder®...
User manual - 1 unit 8. CONSERVATION AND CARE ELECTROMAGNETIC PANELS The electromagnetic panels used in Wonder’s ElectroSuit meet the highest safety standards. The following should be taken into account: - Avoid bumps or falls. - Electromagnetic panels generate heat, so they must be properly ventilated at all times. If you find that the internal fans are not working, contact your provider’s technical support.
Page 13
INTERNAL WIRING SYSTEM Use only the wiring provided by the manufacturer as well as the original power supply. Do not connect the cables to an external power source, as there is a risk of electric shock. Do not use the wiring if it is defective or damaged, as there is a risk of electric shock. Do not connect or disconnect cables during training while the device is connected.
Page 14
9. TREATMENT 9.1. Customer information Before starting treatment, it is mandatory to communicate to the client the aspects inherent to it: Contraindications, Characteristics, Expectations and Side effects. In compliance with international directives, clients should be informed about the risk of placing electrodes in the chest region, which may in certain cases increase the risk of ventricular fibrillation.
Page 15
9.5. SIDE EFFECTS Although treatment is considered harmless, the following side effects may occur: a- Muscle aches b- Skin reaction to the passage of the current in the form of temporary redness or irritation c- In case of excessive treatment in people without habits of muscle exercise can feel nausea or dizziness.
Page 16
11. MANUAL MODE OF USE. PRE-ESTABLISHED PROGRAMMES. 1- MUSCULAR Program for Controlled Muscle Development. It produces hypertrophy, creates new muscle fibers and improves the current ones. It produces a controlled fat burning. 2- DEFINITION Muscle Marking Program. Removes superficial fat and leaves visible muscles. 3- CELLULITIS Vascular Program.
Page 17
AUTOMATIC MODE OF USE. 1- MUSCLE TONING Program for Controlled Muscle Development. It produces hypertrophy, creates new muscle fibers and improves the current ones. It produces a controlled fat burning. 2- BURN FAT Muscle Marking Program. Removes superficial fat and leaves visible muscles. 3- SKIN ENHANCEMENT Vascular Program.
Page 18
Wifi connection close the app Bluetooth connection Langague Free session History of use of equipment Beginning of the session Acess to automatic mode...
Page 19
Intensity Program Pulse width Relationship Contraction - Break Contro of the whole body Time Pulse width / Pulse Widht It indicates the time during which an impulse is applied, usually for a longer duration, the stimulus penetrates deeper into the tissue, recruiting more motor units. Pulse intensity Intensity, measured in milliamperes, is a determining factor in the degree of muscle contraction.
15. POST-TREATMENT CARE During Wonder’s treatment, the organism is subjected to heavy workloads, which will increase blood flow, metabolism and intercellular exchanges. The muscles after the session need to recover their fibers, regenerating the tissues, so they will need to absorb more and better nutrients.
Page 21
MEASURES TO BE TAKEN INTO ACCOUNT Stay properly hydrated before, during and after treatment. Rest completely at least 24 hours after treatment. Decrease or stop alcohol intake. Reduce as much as possible the intake of animal fats, spicy and salt. Eating more proteins, vitamins and minerals to help the body nourish muscle mass.
Page 22
Ionized products can be used that under the action of the current emitted by Wonder will also penetrate the skin. The use of warm water is recommended.
Page 23
18. POSITIVE EFFECTS OF WONDER® Direct muscle formation: the metabolic accelerator, placed through the electrodes in the areas to be precisely stimulated, leads each impulse to affect the appropriate area. Muscle balance formation: external impulses promote the weaker muscles of the body to actively develop.
Page 24
The Wonder device effectively stimulates the pelvic floor muscles; thus providing a very effective pelvic floor muscle strength training. Affected patients report improvement, or in many cases, total elimination of symptoms. Wonder treatment, being for the whole body, if started on time, provides an excellent way to prevent the evolution of such diseases.
19. TECHNICAL SPECIFICATIONS Harmonised standards applied : EN 55014-1(EMC 2004/108/CE) EN 61000-3-2 (EMC 2004/108/CE) EN 61000-3-3(EMC 2004/108/CE) EN 55014-2 (EMC 2004/108/CE) EN 60335-2-27 (DBT 2006/95/CE) EN 60335-1 (DBT 2006/95/CE) National standards and technical specifications applied : UNE-EN 55014-1(EMC 2004/108/CE) UNE-EN 61000-3-2 (EMC 2004/108/CE) UNE-EN 61000-3-3(EMC 2004/108/CE) UNE-EN 55014-2 (EMC 2004/108/CE) UNE-EN 60335-2-27 (DBT 2006/95/CE)
Page 26
Technical specifications of radio frequency emission: Radio Frequency Type: Bipolar by field induction. Type of Waves: Biphasic. Dynamic frequency: 500kHz Number of applicators: 2 units in the abdominal area. Power: 15W in total 20. Warranty The warranty only applies when new equipment is purchased from an official distributor, authorized representative or factory.