Summary of Contents for Water quality VIQUA S1Q-PA
Page 1
Owner’s Manual Models: S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA, S2Q-P/12VDC, S5Q-P/12VDC NSF Standard 55 Class B Validated Models: SV5Q-PA, SV8Q-PA System Tested and Certified by NSF International against CSA B483.1 and NSF/ANSI 55 for Disinfection Performance, Class B 425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t.
Page 2
Congratulations on the purchase of your ultraviolet (UV) water system! This system uses the most advanced UV technology on the market and is designed to provide you with years of trouble free operation with minimal maintenance. To ensure ongoing optimal operation, UV lamps need to be replaced annually with VIQUA factory-supplied replacements.
Safety Information Section 1 Safety Information These are the original instructions. Please read this entire manual before operating this equipment. Pay attention to all danger, warning, and caution statements in this manual. Failure to do so could result in serious personal injury or damage to the equipment.
Page 4
Class B systems are not intended for treatment of contaminated water. 1.3 Water Chemistry Water quality is extremely important for the optimum performance of your UV system. The following levels are recommended for installation: Water Quality and Minerals...
UV system. These water quality parameters can be tested by your local dealer, or by most private analytical laboratories. Proper pre-treatment is essential for the UV system to operate as intended.
Installation 602636 NORTH AMERICAN (NEMA 5-15P), 3-PRONG GROUNDED 602637 CONTINENTAL EUROPEAN (CEE 7/7) 2-PIN WITH GROUND, “SCHUKO” IEC replacement power cords for VIQUA ICE Controller (sold 260012 UK VERSION (BS 1363) 3-PRONG (5 AMP FUSE) GROUNDED separately) 260013 AUSTRALIAN VERSION (AS 3112) 3-PRONG GROUNDED 260019 NO CONNECTOR, 3-WIRE, BARE LEADS Spring...
Page 7
Installation Procedure: Figure 3 shows the installation of a typical UV system and the related components that may be used for the installation. The use of a by-pass assembly is recommended in case the system requires “off-line” maintenance. In this case, note the system requires supplementary disinfectant for the distribution system if any water is used during by-pass condition.
Page 8
Installation installed in one direction only. Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor. Refer to Figure Note: DO NOT solder connections while attached to the system as this could damage the O-ring seals. Outlet port on cell Flow...
Installation 8. Allow the water to run for a few minutes to clear any air or dust that may be in the UV chamber. Note: When there is no flow, the water in the cell will become warm, as the UV lamp is always on. To remedy this, run a cold water tap anywhere in the house for a minute to flush out the warm water.
Maintenance Section 4 Maintenance WA R N I N G • Always disconnect power before performing any work on the UV system. • Always shut-off water flow and release water pressure before servicing. • Regularly inspect your UV system to ensure that the power indicators are on and no alarms are present. •...
Page 11
Maintenance 4.2 Cleaning and Replacing Quartz Sleeve Note: Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing performance. If the sleeve can not be cleaned, it must be replaced.
Operation Section 5 Operation WA R N I N G The advanced warning system has been installed to provide the optimum protection against microbiological contamination in water. DO NOT disregard the warning signals. The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing agency on a regular basis.
Clean sleeve with scale cleaner and eliminate source of staining problem (ie. soften hard water, Quartz sleeve is stained or dirty refer to Section 4.2. Have source water tested to ensure that water quality is still within allowable limits for this Change in feed water quality High Bacteria system. Counts Contamination in water lines after UV UV system must have a bacterial free distribution system to work effectively.
Page 14
Manufacturer’s Dose Flow Chart Section 7 Manufacturer’s Dose Flow Chart Section 8 Specifications: Standard and Validated S5Q-P/12VDC/ S2Q-P/12VDC/ S8Q-PA/ Model S1Q-PA S2Q-PA SV8Q-PA S5Q-PA/SV5Q-PA NSF Class B Certified 5.2 gpm (19.7 lpm) (1.2 m 8.7 gpm (32.9 lpm) (2.0 m 16mJ/cm @ 70% UVT US Public Health 16mJ/cm...
How to Make a Warranty Claim Note: To maximise the performance and reliability of your VIQUA product, the system must be properly sized, installed and maintained. Guidance on the necessary water quality parameters and maintenance requirements can be found in your Owner’s Manual.
Page 16
425 Clair Rd. W, Guelph, Ontario, Canada N1L 1R1 t. (+1) 519.763.1032 • tf. (+1) 800.265.7246 (US and Canada only) t. (+31) 73 747 0144 (Europe only) • f. (+1) 519.763.5069 e-mail: info@viqua.com www.viqua.com...
Need help?
Do you have a question about the VIQUA S1Q-PA and is the answer not in the manual?