Download Print this page
Shihlin electric XST Manual

Shihlin electric XST Manual

Automatic transfer switches

Advertisement

Quick Links

Advertisement

loading
Need help?

Need help?

Do you have a question about the XST and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Shihlin electric XST

  • Page 3 Contents - Overview - Specif ication - Dimension - Installation Precautions...
  • Page 4 Blank: none 1600 K5: XST-5 H: communication 2000 K6: XST-6 2500 1250 current monitor 3200 2500 4000 5000 5000 Note: 1. 2 pole only suitable for frame size below 500AF(including) 2. Add-on can only be choose for XST-6 type ATS-PC...
  • Page 5 ATS Specif ication Frame Size Insulation Voltage, Ui AC800V Rated Impulse Withstand 12kV Voltage, Uimp 2P: AC220 / 230 / 240V Rated Voltage, Ue 3/4P: AC380 / 400 / 415V Control Voltage , Us AC220 / 230 / 240V, 50/60Hz 16, 20 , 25, 32, Rated Current, In (A) 80, 100, 125...
  • Page 6 ATS Specif ication Frame Size 1250 2500 5000 Insulation Voltage, Ui AC800V Rated Impulse Withstand 12kV Voltage, Uimp Rated Voltage, Ue 3/4P: AC380 / 400 / 415V Control Voltage , Us AC220 / 230 / 240V, 50/60Hz Rated Current, In (A) 630, 800 1000, 1250 1600, 2000, 2500...
  • Page 7 Appearance 1. Source I terminal 7. Control circuit terminal 2. Power indicator 8. Insulation barrier 3. Selection button 9. Arc chamber cover 4. Tripping button 10. Auxiliary contact cover 5. Manual operation handle axis 11. Source II terminal 6. Nameplate 12.
  • Page 8 ATS Specif ication XST-5 and XST-6 controllers are usable with the XSTN series three-section PC-class 2P/3P/4P dual power transfer XST-5 and XST-6 controllers are usable with the XSTN series three-section PC-class 2P/3P/4P dual power transfer switch, with frame size from 63AF to 5000AF with the functions of automatic transfer in case of occurrence of power...
  • Page 9 Function List Main functions XST-6 XST-5 Mains - Mains ■ ■ Power supply type Mains - Generator ■ ■ Automatic ■ ■ Operation mode Manual ■ ■ Automatic Back ■ ■ Work mode (Automatic) Manual Back ■ ■ Voltage ■...
  • Page 10 Dimension 16-63A 17.4 9-M6 3-φ 6.8 Safety distance XSTN 16-63A 80-125A 9-M8 3-φ6.8 Safety distance XSTN 80-125A ATS-PC...
  • Page 11 Dimension 160-250A 9-M8 3-φ6.8 Safety distance XSTN 160-250A 350-500A 366.5 228.5 9-φ14 3-φ9 Safety distance 61.5 61.5 XSTN 350-500A ATS-PC...
  • Page 12 Dimension Model 630A 800A “*” Safety distance XSTN 630-800A Model 1000A 1250A “*” Safety distance ATS-PC XSTN 1000-1250A...
  • Page 13 Dimension Model “*” Safety distance XSTN 1600A Model “*” Safety distance ATS-PC XSTN 2000A...
  • Page 14 Dimension Model “*” Safety distance XSTN 2500A 1070 “*” Safety distance ATS-PC XSTN 3200-5000A...
  • Page 15 Installation Precautions 1. Altitude below 2000m 2. Ambient temperature: -25°C ~ +60°C, cannot exceed average of 35°C in 24 hours. 3. Atmospheric conditions: Relative humidity could not exceed 50% when the surrounding temperature is +55°C. For lower temperature, the relative humidity can be higher. 4.
  • Page 16 Maintenance, checking and storing Table 1: Checking and trouble shooting Checking items Check point Trouble shooting 1. Cut-off all power and check with a multimeter. 1. Whether the main circuit connecting wires 2. The silver plating layer on the contact surface is discolored have obvious discoloration.
  • Page 18 SHIHLIN ELECTRIC & ENGINEERING MOTOR CONTROL (CONTACTOR/ MS/ MMS), CIRCUIT BREAKER (MCCB/ ELCB/ EMCCB/ MCB), AIR CIRCUIT BREAKER, AUTOMATIC TRANSFER SWITCHES (Panel Board Type/ Residential Unit Use), SURGE PROTECTIVE DEVICE, LOW VOLTAGE POWER CAPACITORS, SMART METER, INVERTER Breaker & switchgears overseas sales dept.