VaLBIa 86 Series Installation And Instruction Manual

Electric actuators with positioner

Advertisement

VALBIA ELECTRIC ACTUATORS WITH POSITIONER SERIES 86 (VB030M - 350M)
INSTALLATION AND MAINTENACE INSTRUCTIONS MANUAL

TABLE OF CONTENTS

1.0 WARNING
2.0 TRANSPORTATION AND STORAGE
3.0 APPLICATIONS
4.0 ACTUATOR MOUNTING
11.0 DISPOSAL OF THE ELECTRICAL ACTUATORS AT THE END OF THEIR LIFE CYCLE
1.0 Warning
• Please read the following instructions before making any installation of the actuator. The damages caused from the non-observance of these instructions are not
covered in the warranty.
• This documentation must be kept in dry place and available for use.
• The actuator is an electronic device and during its working operations some parts are live components. The installation and maintenance of electric actuator must be
made only by qualified personnel, in accordance with current electrical engineering and safety standards and all other applicable directives.
• Valbia s.r.l. reserves the right to change the data and the characteristics of this manual at any time and with no notice in the scope of a constant updating and
technological improvement.
WARNING: The mechanical and electronic parts, according to which the device has been designed, are not eligible for modifications.
2.0 Transportation and storage
VALBIA electric actuators are supplied in paperboard boxes which are of solid construction for a normal transport. Handle with care and keep the cover until the moment
of the installation of the actuator. The storage of the actuators requires a covered, dry and ventilated environment, protected from temperature changes. The device
must be stored with the cover mounted. Prior to installation, visual inspection is recommended to detect any anomalies caused by transport or storage.
WARNING: do not lift or move the actuator by the manual hand-wheel.
3.0 Applications
VALBIA electric actuators have been designed and tested to ball and butterfly valves and dampers for the industrial sector. Actuators are available in standard version
with rotation 0°-90°. On request we can supply actuators with rotation 0°-180° or 0°-270°. For applications other than that above are needed please contact VALBIA
sales department.
4.0 Actuator Mounting
The mechanical assembling between the electric actuator and the item to be automated (for example: the valve) can be done by direct mounting or by a mounting kit.
Both the cases you can verify the right alignment and the correct dimensions of the part to transmit the power in order to avoid axial stress which can damage valve
and actuator.
All Valbia electric actuators are in conformity of norm EN ISO 5211 (DIN 3337).
In order to have a right automation of the valve, is necessary to use a Valbia electric actuators whose range has a torque of at least 25% over the valve maximum torque.
Verify the actuator duty rating suitability with the application.
WARNING: do not raise up or moved the motorized valve by using the electric actuator as point of grip or hold. Do not grab the actuator by the manual hand-wheel.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 86 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VaLBIa 86 Series

  • Page 1: Table Of Contents

    All Valbia electric actuators are in conformity of norm EN ISO 5211 (DIN 3337). In order to have a right automation of the valve, is necessary to use a Valbia electric actuators whose range has a torque of at least 25% over the valve maximum torque.
  • Page 2: Specifications And Technical Information

    Use copper (CU) conductor (*) in order to guarantee the declared “Type”, the following models of electric connectors should be used: HSK-M (1.609.1200.70) or HSK-K (1.209.1202.70) produced by Hummel AG (E103997). On request the cable glands can be supplied by Valbia. 5.1 Features Here below some technical characteristics of Valbia electric actuators: •...
  • Page 3: Power Requirements And Current Draw Information

    WARNING: Valbia electric actuators may be mounted in many positions, however, we do not suggest using it positioned upside-down or with the cable glands positioned upright, since it cannot guarantee a perfect wiring tightness. If the actuator is mechanically installed but waiting for electrical connections, please ensure that suitable cable entry blanking plugs are fitted.
  • Page 4: Electrical Connection

    6.1 Electrical connection The wiring diagram, which should be followed for proper wiring of the actuators, is shown in paragraph 10.0 and it can also be found inside the upper cover. The signal cable of “positive supply” (+12Vdc / +24Vdc) or “phase” (12Vac / 24Vac / 100-240Vac) can be connected to the pin “1” or to the pin “3” of the terminal block “F”; •...
  • Page 5: Heater

    TERMINAL BLOCK "G" TERMINAL BLOCK “R” Fig.4 Control/logic board and particular of terminal blocks “G” and “R” 6.3 Heater (Fig.5) All the actuators are equipped with “RIS” heating resistor which works only if the actuator is connected to the power supply, when the motor is not rotating and the temperature inside the actuator goes down to 25°C / 77°F.
  • Page 6 2. “Reverse” mode: 20 mA (closed) ÷ 4 mA (open) or 10V (closed) ÷ 0V (open). The “Standard” mode is the default condition. This setting between the operating modes is done using the buttons on the control PCB card: • to enter the programming mode hold down the “M” button for 5 seconds; •...
  • Page 7: Actuator Cover Assembly

    The procedure for the mechanical stops adjustment for models from VB110M to VB350M is the following: The mechanical travel stops are for proper positioning during manual operation and for valve protection in the case of a limit switch failure. Turn off the power. Loosen both travel stop stud bolt nuts.
  • Page 8: Fail-Safe Operation With Battery Backup (Optional)

    Instructions sheet 90004000064 Rev.D VALBIA S.r.l. - Via Industriale, 30 - 25065 Lumezzane S.S. (BS) Italia - T el. +39 030 8969411 - Fax +39 030 8610014 - www.valbia.it - E-mail valbia@bonomi.it...