Mobilex 418E User Manual

Mobilex 418E User Manual

Anti-decubitus mattress

Advertisement

Mobilex A/S
Grønlandsvej 5
DK-8660 Skanderborg
www.mobilex.dk
Anti-decubitus Mattress
418E – 516E - 820Z
User's manual
Manufacturer:
MOBILEX A/S
Grønlandsvej 5
DK-8660 Skanderborg
Denmark
www.mobilex.dk
Rev. 03/15
Page 1 of 7
UM-270001-12-GB

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 418E and is the answer not in the manual?

Questions and answers

Summary of Contents for Mobilex 418E

  • Page 1 Mobilex A/S Grønlandsvej 5 DK-8660 Skanderborg www.mobilex.dk Anti-decubitus Mattress 418E – 516E - 820Z User's manual Manufacturer: MOBILEX A/S Grønlandsvej 5 DK-8660 Skanderborg Denmark www.mobilex.dk Rev. 03/15 Page 1 of 7 UM-270001-12-GB...
  • Page 2: General Information

    Intended use of the device The Mobilex Product is medical device which is intended to be used only as an air support surface system for human body. It is suitable for pressure ulcer prevention and treatment. It has been specifically designed for prevention of bedsores and offers an affordable solution to 24-hour pressure area care.
  • Page 3 1 User manual Sets can be delivered with following Item Numbers and specifications:  Item 27001 consists of: D30 pump & 418E mattress pad  Item 27002 consists of: D30 pump & 516E mattress pad Item 27012 consists of: D30 pump & 820Z mattress pad...
  • Page 4 Mobilex A/S Grønlandsvej 5 DK-8660 Skanderborg www.mobilex.dk Assembly description With looking on the picture above the device should be assembled in quite instinctive way. We recommend you to follow below steps: In the first place take all chair’s elements out of the box and check with the list from above ●...
  • Page 5: Technical Data

    Mobilex A/S Grønlandsvej 5 DK-8660 Skanderborg www.mobilex.dk 4. Technical data System Specification Class I; AP/APG NO*; Type BF** Classification Applied Part Mattress Pad Input Rating AC 120V 60Hz or 100V 50/60Hz or 230V 50Hz 12W, 1A Fuse Rating 250V, T1A...
  • Page 6: Cleaning And Maintenance

    Mobilex A/S Grønlandsvej 5 DK-8660 Skanderborg www.mobilex.dk 5. Cleaning & Maintenance Cleaning In this section, we describe the procedures to clean and decontaminate the pump and bubble pad. It is important to follow these procedures before using the system on patients.
  • Page 7: Disposal Of The Product

    8. Guarantee terms Mobilex A/S offers guarantee by errors in production. It is: 2 years of warranty for pumps production defects & 1 year of warranty for mattress pads production defects.The guarantee is not valid by not- intended use of the product.

This manual is also suitable for:

516e820z

Table of Contents