ECO SOLAR BOOST
FOR HEATING WATER, BOILER
GREEN BOOST
3000 / 3000T
VOLT POLSKA Sp. z o.o.
ul. Swiemirowska 3
81-877 Sopot
www.voltpolska.pl
pomoc@voltpolska.pl | hurt@voltpolska.pl | (58) 500 85 62

Advertisement

loading
Need help?

Need help?

Do you have a question about the GREEN BOOST 3000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Volt Polska GREEN BOOST 3000

  • Page 1 PRODUCT MANUAL wersja 2024-05-27 ECO SOLAR BOOST FOR HEATING WATER, BOILER GREEN BOOST 3000 / 3000T VOLT POLSKA Sp. z o.o. ul. Swiemirowska 3 81-877 Sopot www.voltpolska.pl pomoc@voltpolska.pl | hurt@voltpolska.pl | (58) 500 85 62...
  • Page 2 This manual may be subject to change. Always refer to the latest version of the manual available at https://voltpolska.pl Green Boost 3000/3000T (120-350VDC) for water heating, boilers, underfloor heating, and more. Key Features:High Output Voltage: Even at high input voltages from solar panels, the inverter maintains a stable output voltage of around 245V.
  • Page 3: Intended Use

    INTENDED USE The eco solar boost - Green Boost 3000/3000T (DC 1210-350V) is designed to power heating devices such as boilers, heaters, electric heaters or heating mats directly from PV panels. The system requires: 4 to 9 typical PV panels (250W - 400W) connected in series, with a total voltage from 120V to 350V.
  • Page 4 SAFETY Connecting Solar Panels Cable Requirements: • Use appropriate PV installation cables to connect the panels to the inverter. • Cable cross-section should not be smaller than 4mm². Using excessively thin cables will cause: • Heating • Voltage drop at the inverter input In extreme cases, this can lead to: •...
  • Page 5 The polarity of the supply voltage is very important while connecting PV panels to inverter. The reverse wiring will cause damage to the inverter and void the warranty! The eco solar boost - Green Boost 3000 (DC 1210-350V) has two MC4 connectors which must be connected to the PV installation. The connector shaped...
  • Page 6 SOLAR MPPT PV VOLTAGE STATUS MODE OUTPUT OVER PV CURRENT PRIMARY HEAT OUTPUT SYSTEM OUTPUT VOLTAGE SECONDARY FAULT SOLAR STATUS - When the PV voltage is greater than 80% of the rated voltage of the device, the indicator lamp will be lit. Otherwise, it will blink. OUTPUT PRIMARY - It lights when socket 1 is working OUTPUT SECONDARY - It lights when socket 2 is working PV VOLTAGE - Actual PV input voltage...
  • Page 7 CONNECTING DIAGRAM „1” i „2” Connection Diagram for Terminals "1" and "2" (GREEN BOOST 3000) and Terminal Strip (GREEN BOOST 3000T) GREEN BOOST 3000T GREEN BOOST 3000 SECONDARY (ACTIVE ONLY WHEN NO LOAD PRIMARY ON PRIMARY) WYJŚCIE PODSTAWOWE WYJŚCIE POMOCNICZE...