Do you have a question about the AS1109 and is the answer not in the manual?
Questions and answers
Summary of Contents for ontime AS1109
Page 1
We are the team,We grow together! ONTIME NON-PEDESTAL ANTENNA SOLUTIONS USER MANUAL AS1109/AS1110/OS0263/OT7251 Hangzhou ONTIME I.T. Co.,Ltd. 2023.02...
We are the team,We grow together! CONTENTS 1. Hardwares ....................... 1 1.1 OS0263 AP Station and Remote Control ............1 1.2 AS1109 Padlock Tag ..................3 1.3 AS1110 Sticky Tag ..................4 1.4 Detacher ......................5 2. Instructions ......................5 3. AS1109 Padlock Tag ....................6 3.1 Activate the Tag ...................
We are the team,We grow together! 1. Hardwares 1.1 OS0263 AP Station and Remote Control(OT7251) △ OS0263 AP Station Components Descriptions Power Port Input power is DC 12V Mode Switch Switch to Regional Mode or Access Control Mode Identification Set same ID code to realize the Extension Mode Code Power The indicator is on when power is connected...
Page 4
We are the team,We grow together! △ Remote Control(OT7251) VOL-/VOL+ :Volume adjust button Range-/Range+: Detection Range adjustt( Performance) Alarm Light: Alarm Light Color change (reserved function) Back Light:Background Light Color change (reserved function) 第 2 页...
We are the team,We grow together! 1.2 AS1109 Padlock Tag △ AS1109 Remote Control Components Directions Insert the steel wire to activate the tag, pull out the steel Activating button wire by magnet detacher to deactivate Cut the steel wire will trigger off the alarm, pull out the...
We are the team,We grow together! 1.3 AS1110 Sticky Tag △ AS1110 Picture of Sticky Tag Components Directions tag will be in working mode when the button is pressed Deactivating&Alarm button down, and will alarm if the button is released. dis-alarm by pressing the reset button if the tag alarm is Reset button triggered.
We are the team,We grow together! 1.4 Detacher Only applies to AS1109 Padlock Tag △ Detacher 2. Instructions The Power supply is only required on the OS0263 AP Station, the connection method is as following: 第 5 页...
We are the team,We grow together! △ OS0263 AP Station Power Connection 3. AS1109 Padlock Tag There are 3 working modes of Non-Antenna Solutions: Regional Mode, Access Control Mode, Extension Mode. For Regional Mode, the tag should be bound to the AP Station, for Access Control Mode, binding is not required.
We are the team,We grow together! 3.2 Tag Binding Put the activated Tag close to the AP Station(<20cm), the tag is bound to the AP Station automatically when a ‘Tick’ sounds. △ Picture of binding Tag Unbinding: the tag will automatically unbind with the AP station when unlocking the tag by detacher.
We are the team,We grow together! 3.3 Working Mode AS1109 have 3 working modes: Regional Mode, Access Control Mode, Extension Mode. Regional Mode 1)There’s black switch on the back of OS0263 AP Station, switch it to the Right, will be the Regional Mode, then the AP Station will alarm if the tag is moved out of the detection area.
Page 11
We are the team,We grow together! Access Control Mode △ Black Switch position 1)There’s black switch on the back of OS0263 AP Station, switch it to the left, will be the Access Control Mode, then the AP Station will alarm if the tag is moved in the detection area.
We are the team,We grow together! △ ID code position 3)If the Tag leaves the detection area of AP Station A, AP station A alarms. When the tag goes to the detection area of AP Station B, AP station A stops alarm. 3.4 Change Battery →...
We are the team,We grow together! Control Mode, Extension Mode. For Regional Mode, the tag should be bound to the AP Station, for Access Control Mode, binding is not required. The operation is as following: 4.1 Activate the Tag The tag deactivated automatically when the button ( marked as 1 in the picture below) is pressed.
We are the team,We grow together! △ Picture of binding Tag Unbinding: tear off the tag from the protected product, the tag will automatically unbind when the button is released. 4.3 Working Mode(same as Padlock Tag above) There are 3 working modes: Regional Mode, Access Control Mode, Extension Mode.
Page 15
We are the team,We grow together! △ Black Switch position 2)Stick the tag on the the product to be protected, and put the AP station on the table; 3)When the tag is brought close to the AP station( within 20cm), the tag and AP station will beep twice at the same time, means the tag and AP station is bound automatically.
Page 16
We are the team,We grow together! △Picture of the Sticky Tag 5)Take the tag away from the detection area(beyond 4meters), both the tag and AP station will alarm. 6)Take the product with tag back to the detection area(within 0-4meters), alarm eliminates.
Page 17
We are the team,We grow together! △ Black Switch position 1)There’s black switch on the back of OS0263 AP Station, switch it to the left, will be the Access Control Mode, then the AP Station will alarm if the tag is moved in the detection area.
Page 18
We are the team,We grow together! 4)Take the tag to go through the entrance detection area(within 0-4m), both the Tag and AP station will alarm; 5)Take the tag away from the detection area(beyond 4m), alarm eliminates. Extension Mode With Extension Mode, the detection area can be extended with 2 or more AP Stations.
We are the team,We grow together! △ ID code position 3)If the Tag leaves the detection area of AP Station A, AP station A alarms. When the tag goes to the detection area of AP Station B, AP station A stops alarm. 4.4 Change Battery →...
Page 20
We are the team,We grow together! FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Need help?
Do you have a question about the AS1109 and is the answer not in the manual?
Questions and answers