Any modifications to or abridgments of the document are prohibited without explicit written agreement from J. Schmalz GmbH. J. Schmalz GmbH · Johannes-Schmalz-Str. 1 · 72293 Glatten, Germany · T: +49 7443 2403-0 schmalz@schmalz.de EN-US · 30.30.01.04246 · 00 · 03/24...
ð Failure to follow the instructions in these Operating instructions may result in life-threatening injuries! ð Schmalz is not liable for damage or malfunctions that result from failure to heed these instructions. If you still have questions after reading the technical documentation, contact Schmalz Service at: www.schmalz.com/services...
2.4 Modifications to the Product Schmalz assumes no liability for consequences of modifications over which it has no control: 1. The product must be operated only in its original condition as delivered. 2. Use only original spare parts from Schmalz.
4 Technical Data 4.1 General Parameters Parameter Symbol Limit values Comment min. max. Working temperature of medium and 0° C 45 °C Continuous suction; GCPi not un- environment under continuous load der regulation (vacuum perma- nently < SP1) Storage temperature -10 °C 40 °C ––...
1. Compare the entire delivery with the supplied delivery notes to make sure nothing is missing. 2. Damage caused by defective packaging or occurring in transit must be reported immediately to the carrier and J. Schmalz GmbH. 6 Installation and Start of Operations 6.1 ...
6.2 Installation Site DANGER Risk of fire and explosion due to components that are not explosion-proof Serious injury or death! 4 Do not use the product in environments where there is a risk of explosion! Product Must Not Be Operated in Potentially Explosive Atmospheres. The ambient temperature must be between +5 °C and +45 °C.
Page 8
Do not connect or disconnect the connector under tension and/or when electrical voltage is applied. The device is connected to the power supply via the feed combination. In addition to the plug connection (1) for the mains connection, the feed combination also com- prises the main switch (3) and a 4 A microfuse (2).
6.5 PIN Assignment Connection cable with open cable end Open cable end Line no. Cable color Connected to ... Gray GCPi X02 pin 4 (input GCPi.: pick up) Black GCPi X02 pin 2 (input GCPi.: set down) White GCPi X01 pin 4 (output GCPi.: “Parts present” check) Brown GCPi X01 pin 2 (output GCPi.: error)
For proper disposal, contact a company specializing in the disposal of technical goods and instruct the company to observe the applicable disposal and environmental regulations. 8 Declarations of Conformity 8.1 EU Declaration of Conformity The manufacturer Schmalz confirms that the product described in these instructions fulfills the following applica- ble EU directives: 2014/30/EU Electromagnetic Compatibility...