Page 1
User manual Universal BD103 data logger Code No. 99-97-1238 GB Edition: 10/19...
Page 3
The product named below was developed, designed and manufactured in accordance with the above mentioned EC / EU Directives and under the sole responsibility of Big Dutchman. Description Universal BD103 data logger Serial number and year of construction According to the customer order no. The following harmonised standards were applied: •...
Page 5
Overview of changes / updates Product information Type of / Code of the change / Date of person in Name of chapter update edition Page charge Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 6
Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Observe the comprised safety instructions! If this manual is damaged or lost, request a new copy from Big Dutchman. This manual is protected by copyright. The information and drawings included in this manual may not be copied without the manufacturer's consent, nor may they be misused or disclosed to third parties.
1.2 Supplier's documentation The supplier's documentation includes all instructions for components that are supplied by Big Dutchman but not manufactured by Big Dutchman, for example motors. These instructions are usually supplied with the respective component. If this is not the case or if the language of the corresponding country is not included, please request this documentation from Big Dutchman .
► Make sure that all safety devices are properly mounted and function after work on the system has been completed and before putting the system into operation (again). Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 12
WARNING! Children must not access the system. The safety distances for the system are not designed for children. A risk of injury cannot be excluded, even for supervised children. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
These data can be exported for further processing via internal or externally extended USB interfaces. The Big Dutchman system may only be used for the purpose for which it is designated. Any deviating use is considered non-designated use. The manufacturer shall not be liable for any damage resulting from such non-designated use.
2.5 Ordering of spare parts CAUTION! For you own safety, use original Big Dutchman spare parts only. For third-party products that have not been released or recommended and for modifications (e.g. software, control units), judging whether there is a safety risk in connection with Big Dutchman systems is not possible.
– part 7-705: Requirements for special installations or locations – Agricultural and horticultural premises) for protective-equipotential bonding. The earthing points must be connected with the foundation earth electrode. The material required for earthing is not included in the Big Dutchman delivery. Universal BD103 data logger Edition: 10/19...
3 System description 3.1 Structure and function The universal BD103 data logger has up to 8 channels (1 channel in the standard version) with a power supply of 24 V and an analogue input of 0-10 V each. The logger is therefore suited for operation with a great number of typical 0-10 V sensors of many manufacturers.
Data of PSU Supply voltage 100 – 260 VAC 50/60 Hz Max. current output Data of channels Power supply 24 VDC each Analogue input 0-10 VDC each Available current max. 700 mA in total Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Any connected tasks may only be carried out by authorized and qualified personnel and under consideration of local regulations (e.g. VDE)! 4.1 Connection – power supply 230 V Neutral PE = Earthing V2 = 24 V COM = V1 = Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
4 digital inputs: max. 30 VDC Outputs 4 relays: 10 A at 125 VAC, 5 A at 30 VDC / 250 VAC Ambient temperature 0 - 50 ? Weight 0.350 kg Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 20
Power supply +24 V / GND and CAN bus 0/internal (max. length of the ribbon cable: 2 m) Jumper – termination CAN bus 0 (internal) OFF: terminating resistor is turned off ON: terminating resistor is turned on Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 21
Jumper boot loader To program the controller via USB, set jumpers and restart the controller. Push-button Reserved for service purposes Ethernet interface Not equipped in standard version MicroSD slot Purpose depends on application Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 22
GND = power supply 0 V GND digital = 0 V digital input Digital input 1 Digital input 2 GND digital = 0 V digital input Digital input 3 Digital input 4 Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 23
1: GND 2: Analogue input (0-10 V / 0-20 mA) 3: +24 VDC power supply Relay connection terminals C 1-4: COM connection terminal relay 1-4 S 1-4: Make-contact connection terminal relay 1-4 Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 24
Lit: digital input active Digital input LED 2 green Lit: digital input active Digital input LED 3 green Lit: digital input active Digital input LED 4 green Lit: digital input active Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
1 = State of measured value 2 = Measured value 3 = Selection of input card (8 channels per card) 4 = Log 5 = Settings 6 = Date 7 = Time Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 18 Settings 6 Settings Tap on the gear icon on the start screen to open the settings menu. Use the arrows to reach all settings options. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Select the numbers by pressing and holding the respective field. Select upper/lower case letters by tapping , and delete by tapping on Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
When level 1 is exceeded, the state changes from green to orange . When level 2 is exceeded, the state is displayed in red Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
6.5 Settings – System date Tap on Settings > System date to set the date (dd/mm/yyyy). 6.6 Settings – System time Tap on Settings > System time to set the system time (hh/mm). Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
In American systems, the default separator is the comma (,), in other systems, the semicolon (;). Tap on the floppy disk icon to export the file to the USB flash drive. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
. If no file is selected, the install button is greyed out. When a file is selected, the button turns yellow and becomes active. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
6.10 Settings – Decimal separator Tap on Settings > Decimal separator to select the logger's decimal separator. This separator is used internally and in the exported CSV file from the time of change. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
The log is always displayed for one channel only. Select the desired channel by tapping on the button. Tap anywhere on the screen inside the diagram to select a time. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
2. Press the push-button (marked red in the image) and hold. 3. Reconnect the device to the power supply. 4. After the device has started, release the push-button. The software should now be back to factory settings. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 36
9 Cleaning Clean the exterior of the data logger with a damp cloth in case it is dirty. NOTICE! Make sure that the data logger is not damaged by a high-pressure cleaner. Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 37
Power supply dual 5/24 V 35 W 2.2 A input 100-240 VAC 50/60 Hz NW SNT RD-35B 91-02-6235 Nano I/O, power module 91-02-6208 Nano I/O, analogue in 8 91-02-6239 USB socket for housing installation BD optional optional 103 incl. cable IP65 Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Page 38
As an optional extra, the USB port can be led to the outside if data are to be saved on a regular basis. Code no. Description 91-02-6239 USB socket for housing installation BD 103 incl. cable IP65 Universal BD103 data logger Edition: 10/19 99-97-1238 GB...
Need help?
Do you have a question about the BD103 and is the answer not in the manual?
Questions and answers