User Manual User Manual Level Controller Level Controller NK411 / NK412 NK411 / NK412 TU1.5010.0100.02.02 TU1.5010.0100.03.02 www.hectronic.com...
Page 2
(audio and video) nor in any other kind of data storage - without the prior written consent of Hectronic GmbH. This document may neither be modified or extended nor be used in any other way contrary to its designated use.
Page 3
Hotline number: +49 7703 9388-994 Hectronic GmbH Allmendstrasse 15 D-79848 Bonndorf Tel. +49 7703 9388-0 Fax +49 7703 9388-60 mail@hectronic.com User Manual Level Controller NK411/NK412 www.hectronic.com Managing Directors: Stefan Forster, Eckhard Fechtig, Frank Gampp District Court Freiburg, HRB 621170 VAT ID No.: DE170986709 TU1.5010.0100.03.02...
General Introduction 1.3. Application General Introduction The level controller (NK411 or NK412) forms together with the optoelectronic HecoFill series probe a measuring system for 1.1. Intended Use monitoring liquid levels. The devices and probes meet the highest requirements and have the following approvals: The level controller NK41x is a self-monitoring control unit for the error-free control and monitoring of HecoFill probes.
Warning! Use the terminals on the bottom left of the controller to connect the supply line. Connecting to the Cable length With cable 0,75 mm² shielded max. 1000 m wrong terminal may destroy the device. Connection values According to Hectronic IR specification Remote Acknowledge/ With external button (cable length < 10 m) Test Output...
Mounting ......................................16 Test > 2 sec. Test alarm function 2.3. Installation ......................................17 Operating temperature -25...+60°C 2.3.1. Application Example NK411 ............................ 17 Connection Screw terminals, max. 2,5 mm² 2.3.2. Application Example NK412 ............................ 18 Environmental conditions Usage within buildings 2.4.
The NK411 / NK412 has no switch; for this reason there must be a switch or circuitbreaker in the building installation that is suitably arranged and easily accessible for the user. Furthermore, the switch has to be marked as a disconnector for the device.
An external button can be connected to the terminals 11 and 13 (cable length max. 10 m). The external button has the same function as the internal button. NK411 (with AFS) NK412 (Standard) The serial number of the type plate will be also shown on the front side.
Page 13
With Jumper between Terminals 13 and 15 ...................... 27 Hectronic GmbH Allmendstrasse 15 D-79848 Bonndorf Tel. +49 7703 9388-0 Fax +49 7703 9388-60 mail@hectronic.com User Manual Level Controller NK411/NK412 www.hectronic.com Managing Directors: Stefan Forster, Eckhard Fechtig, Frank Gampp District Court Freiburg, HRB 621170 VAT ID No.: DE170986709 TU1.5010.0100.03.02...
EU Declaration of Conformity Notes: EU Declaration of Conformity Hectronic GmbH Tank- und Parksysteme Address: Allmendstrasse 15, D-79848 Bonndorf declare that the following product with the designation: NK 41x Type: 5010.01001x00 conforms to the provisions of the following Directives under which the relevant harmonised standards have...