TABLE OF CONTENTS SAFETY SYMBOLS The symbols and boxes shown below explain what each heading means. Read and follow all of the messages found throughout the manual. Safety Instructions.......3 DANGER Package Content........5 DANGER: Indicates an imminently hazardous Specification Sheet ........6 situation which, if not avoided, will result in death or serious injury.
SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following. READ AND FOLLOW ALL INSTRUCTIONS DANGER DANGER Drowning. Risk of Potential Risk for certain group of People. • The use of alcohol before or during spa use Check with a doctor before use if pregnant, diabetic, in may lead to unconsciousness with the poor health, or under medical care.
Page 4
SAFETY INSTRUCTIONS(cont.) READ AND FOLLOW ALL INSTRUCTIONS WARNING DANGER • DO NOT add bath oil or bath salt to the spa Electric Shock: Risk of water. • DO NOT use the spa when it is raining, • It is highly recommended to use tap water for spa thundering or lightning.
PACKAGE CONTENT PART DESCRIPTION PART DESCRIPTION Owner's Manual Filter Cartridge Ground Cloth Filter Cover Spa Tub w/storage bag Joint Hose Spa Cover Chemical Dispenser Spa Cover Air Bladder PH Test Strip Control Base Repair Patch Inflation Hose Drainage Regulator Safety Sign Card Inflation Outlet Cap Buckle Key...
ASSEMBLY & OPERATION WARNING WARNING DO NOT install or use the spa if the ambient or water Do not over inflate or use high pressure air compressor temperature is 39°F (4°C) or lower. to inflate. STEP 1 - Unboxing Note: With ambient temperature below 50°F(10°C), it is suggested to keep the package indoor where the temperature is above 59°F(15°C) for at least 2h before unboxing.
Page 8
ASSEMBLY & OPERATION(cont.) Deflate the Spa Tub Wall: Unscrew the one-way valve kit STEP 5 - Leakage Check counter-clockwise to let the air out. • Check if the bottom plug is inserted in the drainage hole properly. Deflate the SPA Cover Air Bladder: Pull valve cap out and squeeze the valve at its base until deflated.
Page 9
ASSEMBLY & OPERATION(cont.) STEP 9. Use the SPA. STEP 7 - Fill the Spa with water. It is highly recommended to fill the spa with tap water to Plug the power cord into a grounded electrical socket minimize the influence of unwanted content, such as and press the RESET button on the GFCI plug.
Page 10
ASSEMBLY & OPERATION(cont.) Control Panel (display) HEATER Press this button to activate the heating system. Once plugged into the power supply (GFCI on TEST/ON), The pump will heat the spa water until the water the control panel will light with a beep. Then the LED temperature reaches the set temperature.
Page 11
ASSEMBLY & OPERATION(cont.) BUBBLE ALARM CODE - HL Press this button to activate the air bubble When the water temperature is higher system(The BUBBLE icon lights). The air bubble than113℉( 45 ℃), HL code flashes and the system is designed with a 20-minute auto- buzzer gives an intermittent alarm.
WATER TREATMENT AND MAINTENANCE Water Treatment Check the following water parameters and adjust them as follows: It is recommended to take a shower before using the spa, as cosmetic products, lotions, and other residues Minimum Ideal Maximum on the skin can quickly degrade water quality.The spa Free chlorine 2 ppm 2 - 4 ppm...
WATER TREATMENT AND MAINTENANCE (cont.) SPA Tub Repair If the spa is torn or punctured, use the provided PVC Repair Patch(N) and glue (not included) : 1. Clean and dry the area to be repaired. 2. Cut the provided PVC patch to appropriate size. 3.
TROUBLESHOOTING Problem Possible Cause Solution CheckforpowerfailurandchechiftheSPAispluggedin Powerfailure. properly(requiresapowersourcerated110~120V,60Hz, singlephase.) Thisproductdrawsacurrentof12AMPS.Itissuggestedto The Control Panel provideaexclusivecircuitbreakertofeedthespaONLY,rated does not light or Householdcircuitbreakertripped. atleast15A.Otherwise,pleasecheckifthecircuitbreaker display tripsduetooverload. GFCItripped TestandresettheGFCI,refertoGFCItestonpage#9. GFCIplugbroken. Contactourcustomerserviceteam. Temperaturesettoolow Setahighertemperature68℉-104℉(20-40°C) Oncethesetwatertemperaturereched,theheaterwillstop The heater system Thewatertemperatureisstill workinguntillthewatertemperaturedrops35.6℉(2°C)below does not work. within35.6℉(2°C)belowtheset thesettemperature.Inthiscase,justwaitforafewminutes temperature. andtheheaterwillstartworkingautomatically. Spaisnotcovered Attachandsecurethecover. Theambienttemperatureislowerthan50ºF(10ºC). Lowambienttemperatureor Outdoorwindspeedisabove3.5-5.4m/s(8-12mph).Thisis strongwind. normal,notaproductqualityissue. Theairbubblefunctionis The spa heats Turnoffthebubblefunction.
Page 15
Thesealgasket/oringonthe Weak air pressure inflationregulatororthejoin during inflation Checkandreplacethesealgasket/oringproperly. hose(H)ismissingorplaced and bubbling. improperly. CUSTOMER SERVICE Thank you for ordering our product. If you have any questions, please feel free to contact us at (562)456-0507 or email to inquiry@hykolity.com. We always find ways to improve!
Need help?
Do you have a question about the BTA-2801 and is the answer not in the manual?