Activating the XACT Gen 4 Monitor with Pressure Sensor
This guide explains how to install and activate the XACT monitor (Generation 4) with pressure sensor.
Overview
XACT monitors are activated using the XACT Pro App available for both Apple and Android devices.
After installing the app you will be able to connect to the XACT monitor using a WiFi connection. Note
WiFi dongles are no longer needed as for Generation 4 monitors. The App connects to the monitor unit
using a WiFi connection provided by the monitor unit. After connecting, the App will detect the monitor
and sensor and guide you through installation and activation. This guide describes the steps.
What to do before you start
Verity that you have account on the XACT Monitoring system my.xactmonitoring.com. If you are not
sure if you have one or have questions please contact your XACT administrator or XACT Support.
Download and install the XACT Pro App. You will find this in the Apple App Store and the Google Play
Store. Use your login email address and password for my.xactmonitoring.com to sign into the app.
Note the app no longer requires an activation code.
Make sure that you have the supplied magnet to operate the monitor's magnetic switch.
Recommended to streamline the activation
Measure the tank dimensions for the activation process.
Determine a location name for the monitor.
Determine the reporting schedule for the monitor
Quick Start Guide
Page 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the Monitor Gen 4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Xact Monitor Gen 4

  • Page 1 XACT administrator or XACT Support. Download and install the XACT Pro App. You will find this in the Apple App Store and the Google Play Store. Use your login email address and password for my.xactmonitoring.com to sign into the app.
  • Page 2 At the tank Locate the monitor on the tank Locate the monitor near the port that will be used for the pressure sensor. If you are using the optional two (2) inch bracket adaptor the monitor can be mounted directly above the port. The monitor can also be mounted directly on steel tanks using the monitors magnetic feet will provide a firm attachment to steel tanks.
  • Page 3 Magnetic switch area Ensure that the XACT Pro app is not open. Holding the supplied magnet over the Magnetic switch area will trigger the sensor. To reboot and activate the monitor hold the magnet over the sensor for approximately 6 seconds. The unit will respond with 5 slow beeps and 5 fast beeps.
  • Page 4 Installing and activating a pressure sensor Select Install/Modify Your devices location will be Select Pressure sensor used by the app set the location of the monitor Note: you may not see this screen if you have given the app permission to use your location previously.
  • Page 5 Installing and activating a pressure sensor Confirm the tank fill level is at least The app will detect if the activation is new Enter a location name for the 50% of capacity. Below that level the monitor. This will be used in or if there is a prior activation of the sensor may not calibrate properly.
  • Page 6 Enter the tank type, shape, and dimensions Enter the tank dimensions. Note Select that tank type you will need to scroll down to enter all the settings. Page 6...
  • Page 7 Option: Set the monitoring schedule Monitors can be configured to Select the days of the week that you Select the hour(s) that you report on a fixed schedule or want the unit to report up to the total would like readings. based on tank levels e.g.
  • Page 8 Option: Setting up weekly plus event monitoring Weekly plus event monitoring provides a weekly reading on the day you choose and alerts triggered by the levels that you set. Select “Event” Select the levels that will trigger alerts and then select the day of the week for the weekly reading.
  • Page 9 Calibration and finishing up Success Select “Calibrate” and follow the instructions The success message indicates the to take readings with the sensor out of the monitor is activated and ready to report tank and submerged to the bottom of the readings.
  • Page 10 There are two ways to verify that your activation was received by the satellite network and XACT System. (1) The Verify Commission feature of the XACT App. This will verify that the commission message was received by the XACT system.
  • Page 11 Remote levels, alerts, and management Following activation the monitor will appear in the Unassigned Zone of your organizations XACT account North 40 #2 Page 11...
  • Page 12 *Note that it is possible to schedule up to 48 readings per day by selecting 2 readings for each scheduled reading. This is intended for situations where redundant transmissions are required. Back to the Scheduling Step If you have questions or need any assistance please contact us : XACT Support (503) 208-6035 support@XACTmonitoring.com Page 12...
  • Page 13: Troubleshooting And Faqs

    If the WiFi signal its lost during the activation process it is necessary to reset the WiFi signal and start the activation process again. You may notice the green Network indicator at the top of the XACT App changes to yellow indicating the signal is lost.