Empty enclosure, copper free aluminum / stainless steel

Advertisement

Quick Links

Instruction Manual
1. Marking
Empty enclosure, Copper free aluminum
EJB*
Empty enclosure, Stainless steel
EJBX*
ATEX certificate: INERIS 14 ATEX 9010U
ATEX marking:
1
I M2
Ex db I Mb (EJBX only)
1
II 2 GD and/or
Ex db IIA or IIB or IIB+H2 Gb and/or
Ex tb IIIC Db
IECEx certificate: IECEx INE 14.0028U
UKCA certificate: CML 21 UKEX 1425U
CCC certificate: 2020322303002546
UL approval: cULus
Empty enclosure E482035 , UL 50E , UL 1203 , CSA C22.2, No. 25, 30
approved for:
Class I, Division 1, Groups B, C, D
Class II, Division 1, Groups E, F, G
Type 4, 4X, 7, 9
ambient temperature:
-25 ... 60 °C (-13 ... 140 °F)
The *-marked letters of the type code are placeholders for versions of the
device.
Pepperl+Fuchs Group
Lilienthalstraße 200, 68307 Mannheim, Germany
Internet: www.pepperl-fuchs.com
2. Target Group, Personnel
Responsibility for planning, assembly, commissioning, operation,
maintenance, and dismounting lies with the plant operator.
The personnel must be appropriately trained and qualified in order to carry
out mounting, installation, commissioning, operation, maintenance, and
dismounting of the device. The trained and qualified personnel must have
read and understood the instruction manual.
3. Reference to Further Documentation
Observe directives, standards, and national laws applicable to the
intended use and the operating location.
The corresponding datasheets, manuals, declarations of conformity, EU-
type examination certificates, certificates, and control drawings
if applicable (see datasheet) are an integral part of this document. You can
find this information under www.pepperl-fuchs.com.
In order to access this documentation, enter the product name, i. e. the
type code, or the item number of the product in the search field of the
website.
For specific device information such as the year of construction,
scan the QR code on the device. As an alternative, enter the serial number
in the serial number search at www.pepperl-fuchs.com.
4. Intended Use
The device is only approved for appropriate and intended use.
Ignoring these instructions will void any warranty and absolve
the manufacturer from any liability.
The enclosures of the EJB* series are made of copper free aluminum.
The enclosures of the EJBX* series are made of stainless steel.
The device can be used indoor.
The device can be used outdoor.
The device can be used in Zone 1.
The device can be used in Zone 21.
The device can be used in Zone 2.
The device can be used in Zone 22.
The device is designed for wall mounting.
The device is designed for mounting to a steel framework.
Use suitable fixing material for mounting.
Mount the enclosure at the fixing points provided.
5. Improper Use
Do not mount the device on the ceiling.
Protection of the personnel and the plant is not ensured if the device
is not used according to its intended use.
DOCT-9234 / 2024-06
6. Mounting and Installation
Ex components are not intended to be used alone. Mounting and usage of
Ex components in devices or systems must be certified separately.
Ex components have the U marking at the end of the certificate number.
Observe the instruction manuals for the associated components.
Observe the installation instructions according to IEC/EN 60079-14.
Observe directives, standards, and national laws applicable to the
intended use and the operating location.
Examples for such regulations are regulations regarding electricity,
grounding, installation as well as hygiene and safety.
If you intend to install the device or enclosure in areas
that may be exposed to aggressive substances, ensure that the stated
surface materials are compatible with these substances. If required,
contact Pepperl+Fuchs for further information.
Ensure that the device provides and maintains a degree of protection
of at least IP66 according to IEC/EN 60079-0.
Observe the requirements
according to IEC/EN 60079-31regarding excessive dust deposits.
In order to guarantee the temperature class, ensure that adequate
free air exists around the enclosure.
The product certification allows smaller distances than the specified
distances according to IEC/EN 60079-14:
Gas group IIA: = 10 mm
l
Gas group IIB: = 10 mm
l
Gas group IIB+H
: = 10 mm
l
2
The enclosure cover is heavy. In order to avoid personal injuries or
property damage, make appropriate provisions for the mounting
procedure.
Do not damage the flamepath surfaces between enclosure and enclosure
cover during the opening of the control panel.
If one of the flamepath surfaces is damaged, exchange enclosure and
enclosure cover.
Before fixing the enclosure cover to the enclosure, protect the flamepath
surfaces with a thin layer of suitable protective grease.
When the cover is fitted, ensure that all fasteners are fully tightened.
Tighten all screws of the enclosure/enclosure cover with the appropriate
torque.
Ensure that there are no external heat sources around the enclosure.
Safety-relevant markings are found on the nameplate supplied.
Ensure that the nameplate is present and legible. Take the ambient
conditions into account.
Additional warning markings may be on separate labels
besides the nameplate.
Ensure that the enclosure is not damaged, distorted, or corroded.
Ensure that all seals are clean, undamaged, and correctly fitted.
Close all unused enclosure holes with the appropriate stopping plugs.
Only use stopping plugs that are suitably certified for the application.
If mounting the enclosure on concrete use expansion anchors.
When mounting the enclosure to a steel framework use vibration resistant
mounting material.
If external connections exist, ensure that the connections
are in good condition, and are not damaged or corroded.
In order to prevent condensation in the enclosure, use suitably certified
breather drains.
6.1. Requirements for Cable Glands
Only use cable glands that are suitably certified for the application.
Only use cable glands with a temperature range appropriate to the
application.
For cable glands only use incoming cable diameters
of the appropriate size.
For control panels with IECEx certification, only use cable glands with
metric thread or NPT thread.
Use seals that are suitable for the specified application.
Ensure that the degree of protection is not violated by the cable glands.
Install cables and cable glands in a way that they are not exposed to
mechanical hazards.
The cables and connection lines must be free from mechanical stress.
Use appropriate strain relief, which must be fitted outside of the enclosure.
Ensure that all cable glands are in good condition and are securely
tightened.
Close all unused cable glands with the appropriate sealing plugs.
Observe the specific ambient conditions of sealing plugs.
Tighten all cable glands with the appropriate torque.
Ground metal cable glands.
7. Operation, Maintenance, Repair
Observe the requirements according to IEC/EN 60079-14
during operation.
Observe IEC/EN 60079-17 for maintenance and inspection.
Observe the requirements according to IEC/EN 60079-19 for repair
and overhaul.
Check the wear on the device and the device components at specific
intervals. The interval between checks depends on the operating
conditions and loads that occur.
1 / 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the EJB Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pepperl+Fuchs EJB Series

  • Page 1 I M2 surface materials are compatible with these substances. If required, Ex db I Mb (EJBX only) contact Pepperl+Fuchs for further information. II 2 GD and/or Ensure that the device provides and maintains a degree of protection Ex db IIA or IIB or IIB+H2 Gb and/or of at least IP66 according to IEC/EN 60079-0.
  • Page 2 Ensure that external ground connections exist, are in good condition, and are not damaged or corroded. If there is a defect, the device must be repaired by Pepperl+Fuchs. Alternatively the device can be repaired by a qualified electrician in compliance with IEC/EN 60079-19.

This manual is also suitable for:

Ejbx series