Table 4 – Stem Kit Number Guide ..........5 Troubleshooting .................. 9 Table 5 – Maintenance Tool Requirements ......5 Appendix A – A Typical Chemical Injection System .... 10 Appendix B – BPR15000D GA and BOM Drawing ....11 Operations and Maintenance Instructions...
BPRs provide a constant pressure to the system with continuous spill-off to the chemical tank that is Gallons Per Day independent of the flow rate. The BPR15000D has a Kg/m Kilograms per Meter maximum operating pressure of 15,000psi and supports Liters Per Hour flow ranges of 0 - 800 GPD and 100 - 2000 GPD.
! NOTICE IT IS RECOMMENDED TO STORE THE ASSEMBLIES IN THE SHIPPING CRATE, IF POSSIBLE. The BPR15000D should be stored in a shelter and be protected from moisture and particulates. Storage temperatures shall be between –50°F and 158°F (–45°C and 70°C).
! NOTICE − 1/2” FKO IF ANY ABNORMALITIES ARE FOUND THROUGHOUT THE If the BPR15000D uses FKO hub connections, the hubs are MAINTENANCE, PLEASE REPORT TO THE RESPECTIVE shipped separately from the valve and will need to be ENGINEERS. installed in the inlet and outlet ports prior to use.
Surface, Back Pressure Regulator BPR15000D 5. Replacing Base O-Ring 6.4 Unscrew the pin holder from the piston. Be careful not to drop the pin (20200) and coil 5/8” Wrench spring (71006349) inside. – 6.5 Remove the old piston cup seal and pin.
Surface, Back Pressure Regulator BPR15000D 7.3 Place a 12mm socket over the seat retainer and rotate counter-clockwise until you can withdraw the old stem assembly from the body. See 12mm Socket, Socket Extension Figure 4. – ! NOTICE USE CARE WHEN REMOVING THE STEM TO AVOID DAMAGING THE INTERNAL SEALING SURFACES OF THE BPR.
Surface, Back Pressure Regulator BPR15000D A – A T PPENDIX YPICAL HEMICAL NJECTION YSTEM NOTES Any number of injection points can be served by a single pump and header system. The only limitation is the flow capability of the pump.
Surface, Back Pressure Regulator BPR15000D B – BPR15000D GA BOM D PPENDIX RAWING Operations and Maintenance Instructions...
Page 13
Surface, Back Pressure Regulator BPR15000D Operations and Maintenance Instructions...
Page 14
Surface, Back Pressure Regulator BPR15000D Operations and Maintenance Instructions...
Page 15
SkoFlo Industries 14241 NE 200 Street Woodinville, WA 98072 USA Tel 1-425-485-7816 Fax 1-425-368-1696 www.SkoFlo.com Operations and Maintenance Instructions DOC-04194 Rev B...
Need help?
Do you have a question about the BPR15000D and is the answer not in the manual?
Questions and answers