1. SAFETY INFORMATION Read and understand this owner’s manual before operating your generator. It will help you avoid accidents if you get familiar with your generator’s safe operation procedures. Never use it indoors Never use it in a wet condition Never directly connect it to a home power system - 5 -...
Page 7
Keep it at least 1m away from Never smoke when fueling inflammables Don’t spill when fueling Stop the engine before fueling - 6 -...
Page 8
Connections to a Home Power Supply If the generator is to be connected to a home power supply as a standby, connection shall be performed by a professional electrician or by another person with proficient electrical skill. When the loads are connected to the generator, please carefully check whether electrical connections are safe and reliable.
Page 9
Generator Ground Circuit In order to prevent electric shock due to shoddy electrical appliances or wrong use of electricity, the generator must be grounded with a good-quality insulated conductor. Ground terminal Make sure the control panel, louver and the inverter bottom side cooling well and without chips, mud and water come in.
2. LOCATION OF IMPORTANT LABELS Please read the following labels carefully before operation this machine. TIP : Maintain or replace safety and instruction labels, as necessary. - 9 -...
3. DISCRIPTION ① Carrying handle ② Fuel tank cap air vent knob ③ Fuel tank cap ④ Control panel ⑤ Recoil starter ⑥ Oil filler cap ⑦ Louver ⑧ Muffler ⑨ Spark plug maintenance cover - 10 -...
3.1 Control panel ① Oil warning light ② Overload indicator light ③ AC pilot light ④ ESC(Engine Smart Control) ⑤ 3 in 1 switch knob (including start/stop switch, fuel valve and choke) ⑥ AC receptacle ⑦ DC receptacle ⑧ Ground (earth) terminal ⑨...
4. CONTROL FUNCTION 4.1 3 in 1 switch knob ① Engine switch \fuel valve “OFF”; Ignition circuit is switched off. Fuel is switched off. The engine will not run. ② Engine switch \fuel valve \ choke “ON” Ignition circuit is switched on. Fuel is switched on. Choke is switched on. The engine can be running.
4.3 Overload indicator light (Red) The overload indicator light ① comes on when an overload of a connected electrical device is detected, the inverter control unit overheats, or the AC output voltage rises. Then, the AC protector will trip, stopping power generation in order to protect the generator and any connected electric devices.
4.5 DC protector The DC protector turns to “OFF” ② automatically when electric device being connected to the generator is operating and current above the rated flows. To use this equipment again, turn on DC protector by pressing its button to “ON” ① ①...
4.7 Fuel tank cap Remove the fuel tank cap by turning it counterclockwise. 4.8 Fuel tank cap air vent knob The fuel tank cap ② is provided with an air vent knob to ① stop fuel flow. The air vent knob must be turned to “ON”.
5. PREPARATION 5.1 Fuel • Fuel is highly flammable and poisonous. Check “SAFETY INFORMA -TION” carefully before filling. • Do not overfill the fuel tank, otherwise it may overflow when the fuel warms up and expands. • After fill the fuel, make sure the fuel tank cap is tightened securely.
5.2 Engine oil The generator has been shipped without engine oil. Do not start the engine till fill with the sufficient engine oil. 1.Place the generator on a level surface. 2.Remove the screws ①, and then remove the cover ②. 3.Remove the oil filler cap ③.
5.3 PRE-OPERATION CHECK If any item in the Pre-operation check is not working properly, have it inspected and repaired before operating the generator. The condition of a generator is the owner’s responsibility. Vital components can start to deteriorate quickly and unexpectedly, even if the generator unused. TIP: Pre-operation checks should be made each time the generator is used.
6. OPERATION • Never operate the engine in a closed area or it may cause unconsciousness and death within a short time. Operate the engine in a well ventilated area. • Before starting the engine, do not connect any electric devices. •...
6.1 Starting the engine 1. Turn the ESC switch to “OFF” ①. 2. Turn the air vent knob to “ON” ② . “CHOKE” ③, 3. Turn the 3 in 1 switch to a. Ignition circuit is switched on. b. Fuel is switched on. c.
• In ambient temperature below 0℃(32℉), the engine will run at the rated r/min (4500r/min) for 5 minutes to warm up the engine. • In ambient temperature below 5℃(41℉), the engine will run at the rated r/min (4500r/min) for 3 minutes to warm up the engine. •...
6.3 Alternating Current (AC) connection Be sure any electric devices are turned off before plugging them in. • Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator. • Be sure the total load is within generator rated output. •...
6.4 Battery Charging TIP: • The generator DC rated voltage is 12V. • Start the engine first, and then connect the generator to the battery for charging. • Before starting to charge the battery, make sure that the DC protector is turned on.
Page 25
• Measure the specific gravity of electrolyte to determine if the battery is fully charged. At full charge, the electrolyte specific gravity is between 1.26 and 1.28. • It is advisable to check the specific gravity of the electrolyte at least once every hour to prevent overcharging the battery.
6.5 Application range When using the generator, make sure the total load is within rated output of a generator. Otherwise, generator damage may occur. 0.4-0.75 Power factor 0.8-0.95 (Efficiency 0.85) ≤1,600W ≤1,280W ≤544W Rated output Rated voltage 12V power ≤1,800W ≤1,440W ≤612W TIP: •...
Page 27
• Do not overload. The total load of all electrical appliances appliance must not exceed the supply range of the generator. Overloading will damage the generator. • When supplying precision equipment, electronic controllers, PCs, Electronic computers, microcomputer based equipment or battery chargers, keep the generator a sufficient distance away to prevent electrical interference from the engine.
7. MAINTENANCE The engine must be properly maintained to ensure its operation be safe, economy and trouble-free, as well as eco-friendly. In order to keep your gasoline engine in good working condition, it must be periodically serviced. The following maintenance schedule and routine inspection procedures must be carefully followed: Thereafter, every First 1 month...
Page 29
• If the gasoline engine frequently works under high temperature or heavy load, change the oil every 25 hours. • If the engine frequently work under dusty or other severe circumstances, clean the air filter element every 10 hours; If necessary, change the air filter element every 25 hours.
7.1 Spark plug inspection The spark plug is important engine components, which should be checked periodically. 1. Remove the cap ① , and use the tool ③ remove the spark plug cap ②, and Insert the tool ⑤ through the hole from the outside of the cover. 2.
7.2 Carburetor adjustment The carburetor is a vital part of the engine. Adjusting should be left to our company authorized dealer with the professional knowledge, specialized date, and equipment to do so properly. 7.3 Engine oil replacement Avoid draining the engine oil immediately after stopping the engine. The oil is hot and should be handled with care to avoid burns.
6. Add engine oil to the upper level. Recommended engine oil: SAE SJ 15W-40 Recommended engine oil grade: API Service SE type or higher Engine oil quantity: 0.35 L 7. Wipe the cover clean, and wipe up any spilled oil. Be sure no foreign material enters the crankcase.
The engine should never run without the foam element; excessive piston and cylinder wear may result. 7. Install the air filter case cover in its original position and tighten the screw. 8. Install the cover and tighten the screws. 7.5 Muffler screen and spark arrester The engine and muffler will be very hot after the engine has been run.
4. Check the muffler screen and spark arrester. Replace them if damaged. 5. Install the spark arrester. TIP: Align the spark arrester projection ⑦ with the hole ⑧ in the muffler pipe. 6. Install the muffler screen and the muffler cap. 7.
3. Take out the fuel filter ⑥. 4. Clean the filter with gasoline. 5. Dry the filter and put it bank into tank. 6. Install the hose and clamp, then open the fuel valve to check whether it is leak. 7.
3. Start the engine ( See Page 20 ) and leave it run until it stops. The engine stops in approx. 20 minutes. Time by running out of fuel. TIP: • Do not connect with any electrical devices. (unloaded operation) •...
9. TROUBLESHOOTING 9.1 Engine won’t start 1. Fuel systems No fuel supplied to combustion chamber. ○ No fuel in tank…Supply fuel. ○ Fuel in tank….Fuel tank cap air vent knob and fuel cock knob to “ON” ○ Clogged fuel filter …. Clean fuel filter. ○...
10. SPECIFICATIONS AGT 2500i Model Inverter Type Rated frequency (Hz) Rated voltage (V) Rated output power (kW) Power factor AC output quality ISO8528 G2 Charging Voltage (DC) (V) Generator Charging Current (DC) (A) Overload Protect (DC) Non-fuse Protector According to Directive 2000/14/EC and 2005/88/EC...
Page 40
2014/30/EU 2000/14/EC (EU) 2016/1628 2014/35/EU EN ISO 8528-13:2016 EN 55012:2007+A1, EN 61000-6-1:2007 EN ISO 3744:2010 ISO 8528-10:1998 89dB(A) Measured power level noise: Guaranteed power level noise: 90dB(A) Location / date: Tunari, 11.01.2022 Technical Manager AGT, Authorized person: Sorin Oprea 93004-Y2V0330-0000...
Need help?
Do you have a question about the AGT2500i and is the answer not in the manual?
Questions and answers