DISPLAY CABINET
TORTUGA
L 900
L 1200
L 1500
Maintenance
And Use Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TORTUGA L 900 and is the answer not in the manual?

Questions and answers

Summary of Contents for AG TORTUGA L 900

  • Page 1 DISPLAY CABINET TORTUGA L 900 L 1200 L 1500 Maintenance And Use Manual Mail: PO Box 116, McLeansville, NC 27301 Street: 555 Birch Creek Rd., McLeansville, NC 27301 Phone:336-856-2919 Fax: 336-217-8838 Email: sales@AdvancedGourmet.com Web: www.AdvancedGourmet.com...
  • Page 2 1. INTRODUCTION PRESENTATION Dear Client, Ciam spa is pleased to number you among its customers and relies the bought machine will match your expectation. In order to get the best performances of the machine, we recommend you to follow all suggestions and instructions, which are included in this manual. 1.2.
  • Page 5: Installation

    4. INSTALLATION 4.1. MACHINE HANDLING The pastry display cabinet handling, from the truck to the final place, has to be made by any truck-lift, which is proper to its weight. The display cabinet shall be always balanced in order to ensure personnel integrity and machine functionality The cabinet can be shipped with or without wood packaging, in case wood crate will be used, will have a pallet base for an easy fork-lift handling.
  • Page 6: Electrical Connection

    4.5. REMOTE CONDENSING UNIT PLACING According to the model of ice cream display cabinet you have No.1 or No.2 internal, or remote, condensing units. The remote condensing unit has to be checked by specialised technicians and according to the required refrigerating power and their position respect the cabinet.
  • Page 7: Extraordinary Maintenance

    ROUTINE MAINTENANCE AND PERIODIC CHECKS These kinds of operations are at client’s expenses. In case some malfunctioning of the unit are observed, please make sure this is not due to non-maintenance reasons, before you apply to qualified assistance. The accurate and periodic cleaning of the unit will reduce the risk of damages to the unit itself and to the products stored within. See following tab for reference.
  • Page 8 DIGITAL FLAVOURS DISPLAY FEEDER RES28 FRONT GLASS LOWER FRAME HEATING ELEMENT ELECTRONIC BALLAST RES29 FRONT GLASSES COUPLING PROFILE HEATING ELEMENT SERVICE VALVE RES30 DOORS FRAME MIDDLE POST HEATING ELEMENT SUPPLY CABLE RES31 GLASSES PERIMETRAL FRAME HEATING ELEMENT AIR CONDENSER RES32 HEATED DOORS HEATING ELEMENTS ELECTRONIC CONTROL RES33...
  • Page 10 dIXEL Installing and Operating Instructions 1592027050 probes is more than the value of the Fct parameter, the fans are switched on. With Fct=0 the function is disabled. Digital controller for medium-low temperature 3.3.2 Cyclical activation of the fans with compressor off. refrigeration applications When Fnc = c-n or c-Y (fans in parallel to the compressor), by means of the Fon and FoF parameters the fans can carry out on and off cycles even if the compressor is switched off.
  • Page 11: Max & Min Temperature Memorization

    dIXEL Installing and Operating Instructions 1592027050 6.6.1 HOW TO ENTER THE HIDDEN MENU To enter in programming mode. 1. Enter the Programming mode by pressing the Set + n keys for 3s (the “°C” or “°F” LED starts To return to the room temperature display. blinking).
  • Page 12 dIXEL Installing and Operating Instructions 1592027050 Lod Instrument display: (P1; P2, P3, P4, SET, dtr): it selects which probe is displayed by the CONDENSER TEMPERATURE ALARM instrument: P1 = Thermostat probe; P2 = Evaporator probe; P3 = Third probe(only for model AP2 Probe selection for temperature alarm of condenser: nP = no probe;...
  • Page 13 dIXEL Installing and Operating Instructions 1592027050 PbC Type of probe: it allows to set the kind of probe used by the instrument: PbC = PBC probe, ntc 11.1 CUT OUT = NTC probe. onF on/off key enabling: nu = disabled; oFF = enabled; ES = not set it. dP1 Thermostat probe display dP2 Evaporator probe display dP3 Third probe display- optional.
  • Page 14 dIXEL Installing and Operating Instructions 1592027050 Label Name Range °C/°F Level Message Cause Outputs AC Anti-short cycle delay 0 50 min "LA2" Condenser low temperature It depends on the “bLL” parameter Ac1 Second compressor start delay 0÷255s “dA” Door open Compressor and fans restarts rtr P1-P2 percentage for regulation 0 ÷...
  • Page 15 dIXEL Installing and Operating Instructions 1592027050 Label Name Range °C/°F Level Ld1* 1 workdays defrost start 0 ÷ 23h 50 min. - nu Ld2* 2 workdays defrost start 0 ÷ 23h 50 min. - nu 13.0 Ld3* 3 workdays defrost start 0 ÷...