Advertisement

Quick Links

SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-07HR03/R2
HSU-09HR03/R2
HSU-12HR03/R2
Please read this operation manual before using the air conditioner.
No.0010562822

Advertisement

Table of Contents
loading

Summary of Contents for Haier HSU-07HR03

  • Page 1: Operation Manual

    SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL HSU-07HR03/R2 HSU-09HR03/R2 HSU-12HR03/R2 Please read this operation manual before using the air conditioner. No.0010562822...
  • Page 2 User's Guide caref- inoperative and safe. Unplug the air conditioner ully. The User's Guide contains very impor- in order to avoid the risk of child entrapment. tant observations relating to the assembly, operation and maintenance of the air It must be noticed that air conditioner system conditioner.
  • Page 3: Specifications

    3. If the fuse of indoor unit on PC board is broken,please change it with the type of T. 3.15A/ 250V. 4. The wiring method should be in line with the local wiring standard.
  • Page 4: Safety Instruction

    Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage. lnstallation in a inadequate place may cause accidents. Do not install in the following place. CAUTION Do not install in the...
  • Page 5 PROHIBITION PROHIBITION CAUTION Take fresh air occasionally especially Do not operate the switch with Do not use for the purpose of storage of food, art work, precise equipment, when gas appliance is running at the wet hand. breeding, or cultivation.
  • Page 6: Parts And Functions

    Lights up when unit starts. adjust up and down air flow. is selected. running. (Don't adjust it manually.) Actual inlet grille may vary from the one shown in the manual according to the product purchased Outdoor Unit OUTLET CONNECTING PIPING AND ELECTRICAL WIRING...
  • Page 7: Clock Set

    NOTE:(1)The following functions and related displays are not available: AUXILIARY HEAT display, POWER/SOFT display, LOCK display. (2)If the Air conditioner don't have the function of the code ,press code B can cause it not available. (3)Cooling only unit do not have functions and displays related with heating.
  • Page 8 NOTE:(1)The following functions and related displays are not available: AUXILIARY HEAT display, POWER/SOFT display,HEALTH display. (2)If the Air conditioner don't have the function of the code ,press code B can cause it not available. (3)Cooling only unit do not have functions and displays related with heating.
  • Page 9: Operation

    When sudden power failure happens during unit operation in power failure resume mode, if the air conditioner is not desired for use in a long period, please shut off the power supply in case that the unit automatically resume operation when power is re-supplied, or press...
  • Page 10 All indicators on indoor unit go out. Vertical flap closed automatically. Hints Remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reselecting is needed.(TIMER ON/OFF needs reselecting)
  • Page 11: Cool,Heat And Dry Operation

    LOW speed regardless of FAN setting. Hints On cooling only unit, heating mode is not available. Remote controller can memorize each operation status. When starting it next time, just press ON/OFF button and unit will run in previous status.
  • Page 12: Air Flow Direction Adjustment

    Be careful not to catch a cold when cold air blows downward. It is harmful to your health in summer to go frequently in and out of places where temp. difference is above 7 C.
  • Page 13: Timer Operation

    TIMER Operation Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following times: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
  • Page 14 Follow the same procedures in "Time setting for TIMER ON". (6) Time confirming for TIMER OFF After time setting, press SET button to confirm, "OFF" stops flashing Time displayed: Unit stops at X hour X min. To cancel TIMER mode...
  • Page 15: Health Mode Operation

    The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air...
  • Page 16: Emergency And Test Operation

    Removal of the restriction of emergency or test operation: Press once more the emergency operation switch, or manipulate through the remote controller, a "Pi" sound causes the restriction of emergency or test operation to be removed. When the remote controller is manipulated for the removal, then the selected operation...
  • Page 17 Operation Comfortable SLEEP Before going to bed at night, you can simply press the SLEEP button and unit will bring you a sound sleep in selected mode. In COOL mode One hour after SLEEP mode starts, temp. will become 1 C higher than temp.
  • Page 18: Maintenance

    Cut off power supply before cleaning unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. squeeze water in the cloth, wipe off the detergent on unit casing completely. Cleaning of remote controller Don't use water to wash unit casing, please use dry cloth.
  • Page 19 Close the inlet Grille Close the Grille surely. The air conditioner which you are using may be different from the upper illustration, please refer to the upper installation methods. NOTE: Please replace the Air Purifying Filter in 3-6 months as standard.
  • Page 20 Avoid time-wasteful operation Never fail to observe the followings Do not sprinkle water over Do not block the inlet or outlet. the unit. Do not pull power plug. Do not use for other purposes. Such as food preservation plant cultivation or animal breeding.
  • Page 21: Troubleshooting

    Performance casing expanding or shrinking because of inspection temperature changes Should there be a big noise from air flow in unit operation, air filter may be too dirty. This is because the system circulates smells Smells are generated. from the interior air such as the smell of furniture, cigarettes.

This manual is also suitable for:

Hsu-07hr03/r2Hsu-09hr03/r2Hsu-12hr03/r2

Table of Contents