Instructions
Removable Starter Length
Midtherm HT-S Starter Length has a 0.9mm inner liner so that it can be fitted directly to a stove
where permitted by the stove manufacturer. Stove manufacturer's installation instructions and
building regulations must be followed.
Carbon Monoxide detectors must be installed for solid fuel installations.
Use fire rope to make an airtight seal onto the appliance wherever possible.
Operation: If spillage is seen from any flue joints, discontinue the use of the appliance until
inspected by a qualified / competent chimney sweep.
Maintenance: Remove cover band and insulation, inspect joint for air tightness. Carry out smoke
test without cover band fitted.
Please also refer to HT-S installation Instructions (available to download from our website).
HT-S is tested to BS EN 156-1. BS EN 15287 allows BS EN 1856-1 chimneys to be used as connecting
flue pipes. SW 316 0.9mm is tested to BS EN 1856-2 and forms the inner liner of the HT-S 0.9mm
inner products including the starter lengths.
The most stringent regulations must be
adhered to
As the appliance connector section
insulation may be irregular following
installation the distance to combustibles
should be increased.
Midtherm Flue Systems Limited, New Road, Dudley, West Midlands, DY2 8SY
t
+44(0)1384 458800
Distance to Combustibles
HT-S
Lengths
T450 =
50mm
e
sales@midthermflue.co.uk
Appliance Connector
Section
1.5 x Diameter (200mm
minimum -EN15287)
w
midthermflue.co.uk
HT-S - 0860
Appliance
See Appliance
installation
insutructions

Advertisement

loading
Need help?

Need help?

Do you have a question about the HT-S and is the answer not in the manual?

Questions and answers

Summary of Contents for MIDTHERM HT-S

  • Page 1 Please also refer to HT-S installation Instructions (available to download from our website). HT-S is tested to BS EN 156-1. BS EN 15287 allows BS EN 1856-1 chimneys to be used as connecting flue pipes. SW 316 0.9mm is tested to BS EN 1856-2 and forms the inner liner of the HT-S 0.9mm inner products including the starter lengths.
  • Page 2 COMPONENTS Door with Draught Test Point Removable Setting Band Special Appliance Connector White Blanket Insulation Cover Band Locking Band Available in stainless or matt black powder coat finish Installation to achieve 600mm off the top of appliance before change of direction...
  • Page 3 DIRECT - Installation directly off appliance RETROFIT - Installation to retrofit stove when HT-S is already installed on-site To remove appliance follow the retrofit installation in reverse.
  • Page 4 . Don’t forget to register your warranty online at midthermflue.co.uk/products/ht-s Midtherm Flue Systems Limited, New Road, Dudley, West Midlands, DY2 8SY +44(0)1384 458800 sales@midthermflue.co.uk midthermflue.co.uk...