V-TUF VTPM3 User & Operator Manual

V-TUF VTPM3 User & Operator Manual

Electric industrial cold water high pressure pump motor

Advertisement

Quick Links

COLD WATER HIGH PRESSURE PUMP MOTOR
User Operators Manual
CE
© V-TUF
VTPM3 & VTPM4
ELECTRIC INDUSTRIAL
415volt
English
Operators
Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VTPM3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for V-TUF VTPM3

  • Page 1 VTPM3 & VTPM4 ELECTRIC INDUSTRIAL COLD WATER HIGH PRESSURE PUMP MOTOR 415volt User Operators Manual English Operators Manual © V-TUF...
  • Page 2: Table Of Contents

    Contents Page No Description / Contents Important safety Instructions Safety Features Precautions Technical Data Identification Data Use the of machine Transport & Lifting Cleaning Applications 16 – 18 Troubleshooting Water Flow Diagram Notes...
  • Page 3: Important Safety Instructions

    High pressure cleaners must not be used by children or untrained personnel. High pressure hoses, fittings and couplings are important for the safety of the appliance. Use only hoses, fittings and couplings recommended by V-TUF. Always wear suitable eye, face and body protection.
  • Page 4 V-TUF, quoting type of machine, matriculation number and the year of manufacture. Trial before shipment The machine has been tested at the manufacturer’s factory by a V-TUF technician to check that all of the components are functioning correctly according to the machine’s specifications. Guarantee Terms...
  • Page 5 Delivery The transport will be carried out by qualified companies, in respect to regulations in force and legislation relative to weight and length. The merchandise travels under the full responsibility of the transporter and the user; in the event of an accident, or late delivery, the manufacturer accepts no liability.
  • Page 6 Prior to use, please carefully read the instructions, paying particular attention to "IMPORTANT RECOMMENDATIONS", "SECURITY NORMS" and "PRECAUTIONS". It is forbidden to remove or tamper with the protective parts of the machine. It is forbidden to use inflammable, explosive or toxic substances. It is obligatory to use appropriate protective equipment.
  • Page 7 Your machine is supplied with electronic apparatus, the use of which requires the observation of the following safety criteria. Before using the product, please inspect the unit to make sure it is safe to use and for any damage or any areas of concern. When using the machine outdoors, do not use when it is raining Take great care not to damage the electrical power supply lead, in case if the cable is damaged do not attempt a precarious repair.
  • Page 8 Do not use combustible materials other than those advised by the constructor. Once you have finished working, and after the machine has stopped, release the residual pressure in the tube and pump by squeezing the pistol lever. It is strongly forbidden to carry out any operation with the machine if you are not wearing the appropriate safety equipment (protective glasses, gloves, overalls etc) as per established safety norms.
  • Page 9 PRECAUTIONS Before activating the high pressure cleaner, make certain that the water supply is correct (min. 1 Bar – Max 8 Bar); dry use can provoke serious damage to the machine’s waterproofing systems. To safeguard the security of the operator and of the machine, avoid making modifications to the machine without the written consent of the manufacturer.
  • Page 10: Technical Data

    Dimensions: (L x W x H) cm 630 x 260 x 280mm The V-TUF VTUF VTPM high pressure pump motor kits are tough, well built, well proven, reliable Electric Pressure Washer pumps with the ideal balance of pressure and flow for its voltage in the construction sites, agriculture and industry.
  • Page 11: Identification Data

    MODEL: VTPM3 or VTPM4 ATTENTION: Check that your V-TUF high pressure washer has been provided with these identification details, if they have not been provided, please inform your local dealer immediately. Machines which have not been provided with these details MUST NOT BE USED and should be considered anonymous and potentially dangerous.
  • Page 12 LUBRICATION OF THE PUMP For the models VTPM3 & VTPM4 we recommend: V-TUF Pressure Lube PL500 – OIL CAPACITY 0.5 litres You should change the oil after the first 50 hours of use, and after each subsequent 500 hours of operation.
  • Page 13: Transport & Lifting

    TRANSPORT – LIFTING – SHIFTING ATTENTION: Whenever the machine needs to be transported, it should be securely fixed with straps, cables or other suitable equipment in order to avoid accidental movement which could cause damage to people or property as well as to the machine itself. ATTENTION: Should the machine need to be lifted, it should be hooked or coupled by means of straps, or suitable lifting equipment which will safeguard the machine’s integrity.
  • Page 14 STORAGE Park the machine on a flat surface. If the machine is not going to be used for an extended period of time, empty the water circuits and then cover the machine and store it in a place protected from atmospheric extremes.
  • Page 15: Cleaning Applications

    Cleaning Applications MARKET SECTOR APPLICATIONS Automotive Cleaning Services, such as car washes, and vehicle cleaning in yards like courier’s fleet of trucks and vans. Public Sector Cleaning outside of hotels and other public eating areas, including car parks, and entrance steps to buildings. Construction Industry Cleaning the outside of buildings, concrete &...
  • Page 16: Troubleshooting

    Troubleshooting PROBLEMS CAUSES SOLUTIONS The pump turns but does not The pump is sucking in air if you are Check that the suction line is airtight reach the required pressure running on suction Use a ‘water reserve’ supply kit or suck Your water supply may not be water from a tank.
  • Page 17 Oil is a milky colour (Presence of Pump piston seals may be worn Replace the oil and if it goes milky water in the pump oil) quickly again, replace pump seals and High percentage of humidity on the Change the oil twice as often as is air.
  • Page 18 Oil discharge from between the Worn out oil seals. Replace the oil seals. pump body and the pump head. Excessive vibrations. Worn out or dirty valves. Inspect and clean or replace the valves. The electric motor does not There is no electric current. Check that the plug is securely inserted start.
  • Page 19: Water Flow Diagram

    WATER FLOW DIAGRAM Notes: 19 | P a g e...