Do you have a question about the ACTILIT HB59439BTT and is the answer not in the manual?
Questions and answers
Summary of Contents for AHF ACTILIT HB59439BTT
Page 1
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION ACTILIT Bed Item numbers HB59439BTT / HB59439BTT80 The information of this document can be updated without notice and is not in any way binding to ATELIERS DU HAUT FOREZ. Any complete or partial representation or reproduction without the prior approval of ATELIERS DU HAUT FOREZ is prohibited.
Page 2
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Your Options Casters ☐ Casters ∅ 125mm (2 with brakes) ☐ Single-roller servo-casters ∅ 125mm ☐ Single-roller servo-casters ∅ 150mm ☐ Double rollers servo-casters ∅ 125mm ☐ Double rollers servo-casters ∅ 150mm 5th caster ☐...
Page 3
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION This bed has been manufactured by les Ateliers du Haut Forez, located in la Tourette (Loire, France). MARKING SYMBOLS Read the operating instructions before starting to use the bed. Danger – read the accompanying documents Class I device –...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION A-1-1 Suitable environments for ME systems ....................7 A-1-2 Technical performance ........................9 A-1-3 Clinical safety ............................9 A-2 Transport and storage ...................... 11 A-3 Entry into service ......................11 A-4 Recommendations for use ....................12 A-4-1 Immobilization and conveyance ......................
Page 5
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Page | 5...
Page 6
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION A – USE A-1 Application The electric bed called « ACTILIT » is a medical bed. The NF EN 60601-2-52 standard defines a medical bed as follows: « device for which the INTENDED use is sleeping/resting that contains a MATTRESS SUPPORT PLATFORM and intended to assist in diagnosis, monitoring, prevention, treatment, alleviation of disease ir compensation for an injury or handicap ».
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION A-1-1 Suitable environments for ME systems This medical bed is designed to be used within the electromagnetic environment described below. The customer or user of this bed has to make sure that the latter is used in a professional healthcare facility.
Page 8
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION IMMUNITY Test Requirements Compliance level ± 8 kV (contact) ± 8 kV (contact) Electrostatic discharge ± 2/4/8/15 kV (air) ± 2/4/8/15 kV (air) IEC 61000-4-2 3V/m (professional care facilities) 3V/m Radiated 80MHz-2.7GHz 80MHz-2.7GHz electromagnetic fields...
52, IEC 60601-1-2, et NF EN 60601-1. These standards ensure the bed’s functionalities and the clinical safety of the patient. A-1-3 Clinical safety The claims made by AHF regarding the clinical safety of the patient and the user are the following: Electromagnetic risks prevention: According to the standard NF EN 60601-1-2, the characteristics of the electromagnetic emissions of the bed HP57439BTT allow the use of this bed in industrial areas and hospitals.
Page 10
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Risk’s prevention associated with the movement of the bed (NF EN 60601-2-52): The bed does not tip even when positioned in its most unfavorable position. The necessary strength to move the bed along a hard and smooth surface does not exceed 200N.
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION A-2 Transport and storage When handling the bed for storage, it is advised: * To strap it to a support on the means of transport, To cover it To make sure the brakes are activated The clearance of the doors and/or the elevator must be 2200 mm long and/or 1100 mm wide to be able to accommodate the bed.
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION A-4 Recommendations for use This document contains recommendations for use you have to comply with. This document has to be stocked and be accessible to the whole staff. A-4-1 Immobilization and conveyance When there is no need to move the bed, the bed has to be immobilized thanks to the brakes.
When working on or disinfecting the bed, the bed must be unplugged from the mains and the battery must be removed. This chapter is applicable with the bed and all AHF accessories. Recommendations: Please use only the authorized and standardized cleaning and disinfectant products...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION We advise to clean from the top to the bottom, and to be particularly cautious with the areas directly in contact with the patient. Begin with the furniture close to the patient. Prohibited products Solvents: petroleum,...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Non-observance of the maintenance table Non-observance of the disinfection protocol The use of accessories not distributed by the manufacturer An abnormal use (see below) A-6-1 Abnormal uses This bed is a medical device designed and adapted for a specific use. Abnormal use of this equipment may cause accidents for the user and even irreparable damage.
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION The bed must never be handled by one of these elements : Accessories fitted on the bed Side-rails Remote-controller or electrical cables A-7 Traceability To identify the serial number of the bed, refer to the identification label of the bed. This label located...
Page 17
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Page | 17...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION B - CHARACTERISTICS (depending on your options) B-1 ¾ siderails with polypropylene panels (HB59439BTT only) Page | 18...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C - MANIPULATIONS C-1 Use of the bed C-1-1 Manual rest of the backrest In an emergency or if there is a power cut, the red lever situated under the lying surface on either side of the bed allows the backrest to return to flat. CPR handle How to proceed: * Hold the backrest,...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C-1-2 Brake pedal (servo casters) Steerable position Free position Brake position This pedal enables the caregivers to completely lock the 4 casters of the bed with only one movement. Press the pedal with the foot to its lowest position to lock the casters. To activate the steerable caster move the pedal up to its highest position.
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C-1-4 Electric remote controls This hand control can be used by the patients. But its activation or not can only be controlled by the nursing staff. > The green light (15) indicates that the hand control’s power in on. >...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C-1-6 Patient satellite remote (option) This remote can be used by the patients. 1- Nightlight 2- Back rest (up) 3- Thigh (up) 4- Foot (up) 5- Bed surface height (up) 6- Armchair position 7- Night position (flat lying surface) 8- Bed surface height (low)
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C-1-7 Battery Battery is located in the power supply box, under the bedbase. Battery allows the use of the bed in emergency situations when the bed is no longer powered by the power supply. When the battery is completely empty, charging time is about 12hours.
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C-2 Accessories For IV drip stand LSUGHPSTALNM, refer to instructions of use of the IV drip stand (91200220) For trapeze bar LSUGHPL and LSUGHPLE, refer to instructions of use of the trapeze bar (91201220) C-2-1 ¾...
Page 28
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Locking-parts (red parts) Locking button Assembling/removal procedure To withdraw the side rail from the bed, fold down the latter. Raise the 2 lock parts (red parts) to remove them from the support tube of the side rail. Then, pull the side rails to remove it from the bed base.
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C-2-2 Half barriers Please take into account the following recommendations before handling the side rails. It will ensure their correct operation and guarantee the safety of users. The LSUGH2BPLTA2 and LSUGH2BPLP1/2A side rails are the only rails that can be used on our ACTILIT bed.
Page 30
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Page | 30...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION C-2-3 Mattress dimensions Whatever the type of mattress, please strictly respect the below dimensions : For HB59439BTT80 80cm width bed, dimensions are the followings: Page | 31...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION D-MAINTENANCE D-1 Entretien préventif Bed lifetime: 10 years. The preventive maintenance does not require the presence of an external professional (except for the level 3,4 and 5 – see maintenance table). A document to register the maintenance operation is available (appendix I). With the help of our aftersales service, you can get access to aftersales instructions upon request.
NOTICE D’UTILISATION – LIT ACTILIT VERSION 2023 E-USED EQUIPMENTS When an equipment reaches its end of life, it must be part of the recycling loop. The used battery has to be dropped in a batteries box or given to a dedicated structure. Ateliers du Haut Forez is able to organize and supervise the disposal step.
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION APPENDIX I Maintenance – Quality control User’s identification Identification produit Customer/company : Room number : Address : Type : Phone : Brand/name/type : Check date : Serial number : Qualitative aspect Comments Visual check The identification/label is in good condition The welding and painting are in good condition...
Page 42
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION Siderails of the bed Comments Good positioning and mounting The locking of the side rails in their different positions is working The mechanisms are in good condition, so are the fixing system of the siderails (welding, screws) Serial number of the siderails : Defective parts...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION APPENDIX II: Aftersales service Tel 04 77 50 74 89 Fax 04 77 50 06 05 QUOTATION REQUEST : INTERVENTION REQUEST : SPARE PARTS REQUEST : SPARE VIEWS REQUEST : DATE : INTERVENTION UNDER WARRANTY ATTENTION : if the warranty is no longer justified, the intervention will be invoiced CUSTOMER :...
INSTRUCTIONS FOR USE – ACTILIT BED 2022 EDITION ANNEXE III : Request for the implementation of a preventive maintenance policy …………………….. …………………….. …………………….. Ateliers du Haut Forez Technical services department Ateliers du Haut Forez ZAC la Gravoux 42380 la Tourette Tel : 04.77.50.74.89 Fax : 04.77.50.06.05 Objet : Request for the implementation of a preventive maintenance policy...
Need help?
Do you have a question about the ACTILIT HB59439BTT and is the answer not in the manual?
Questions and answers