Model Number
601A02
Performance
Sensitivity(± 20 %)
Measurement Range
Frequency Range(± 5 %)
Frequency
Range(± 10 %)
Frequency
Range(± 3 dB)
Resonant Frequency
Broadband Resolution(1 to 10,000 Hz)
Non-Linearity
Transverse Sensitivity
Environmental
Overload Limit(Shock)
Temperature Range
Temperature Response
Enclosure Rating
Electrical
Settling Time(within 1% of bias)
Discharge Time Constant
Excitation Voltage
Constant Current Excitation
Output Impedance
Output Bias Voltage
Spectral Noise(10 Hz)
Spectral
Noise(100 Hz)
Spectral
Noise(1 kHz)
Electrical Isolation(Case)
Physical
Size (Hex x Height)
Weight
Mounting Thread
Mounting Torque
Sensing Element
Sensing Geometry
Housing Material
Sealing
Electrical Connector
Electrical Connection Position
[6]
All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.
®
ICP
is a registered trademark of PCB Group, Inc.
LOW-COST INDUSTRIAL ICP® ACCELEROMETER
ENGLISH
SI
500 mV/g
51 mV/(m/s²)
± 10 g
± 98 m/s²
28 to 240,000 cpm
0.47 to 4000 Hz
20 to 300,000 cpm
0.33 to 5000 Hz
10 to 600,000 cpm
0.17 to 10,000 Hz
960 kcpm
16 kHz
35 µg
343 µm/sec
± 1 %
± 1 %
≤ 7 %
≤ 7 %
5000 g pk
49,050 m/s² pk
-65 to +250 °F
-54 to +121 °C
See Graph
See Graph
IP68
IP68
≤ 10 sec
≤ 10 sec
≥ 1.0 sec
≥ 1.0 sec
18 to 28 VDC
18 to 28 VDC
2 to 20 mA
2 to 20 mA
<150 Ohm
<150 Ohm
8 to 12 VDC
8 to 12 VDC
2
3 µg/√Hz
29.4 (µm/sec
2
0.7 µg/√Hz
6.9 (µm/sec
2
0.5 µg/√Hz
4.9 (µm/sec
8
8
>10
Ohm
>10
Ohm
7/8 in x 1.94 in
22.2 mm x 49.3 mm
2.8 oz
80 gm
1/4-28 Female
N/A
2 to 5 ft-lb
2.7 to 6.8 Nm
Ceramic
Ceramic
Shear
Shear
Stainless Steel
Stainless Steel
Welded Hermetic
Welded Hermetic
2-Pin MIL-C-5015
2-Pin MIL-C-5015
Top
Top
[2]
Optional versions have identical specifications and accessories as listed for the standard model
except where noted below. More than one option may be used.
[3]
M
- Metric Mount
Supplied Accessory : Model M081A61 Mounting Stud 1/4-28 to M6 X 1 (1) replaces Model
081A40
[1]
2
[1]
[4]
[1]
NOTES:
[1] Typical.
[2] Conversion Factor 1g = 9.81 m/s².
[3] The high frequency tolerance is accurate within ±10% of the specified frequency.
[4] Zero-based, least-squares, straight line method.
[5] 1/4-28 has no equivalent in S.I. units.
[6] See PCB Declaration of Conformance PS023 for details.
[1]
)/√Hz
[1]
)/√Hz
[1]
)/√Hz
[5]
SUPPLIED ACCESSORIES:
Model 081A40 Mounting Stud (1)
Model ICS-2 NIST-traceable single-point amplitude response calibration at 6000 cpm (100 Hz)
for each axis (1)
Entered: LK
Engineer: BAM
Date: 4/5/2019
Date: 4/5/2019
3425 Walden Avenue, Depew, NY 14043
Revision: E
ECN #: 49314
OPTIONAL VERSIONS
Sales: MC
Approved: BAM
Spec Number:
Date: 4/5/2019
Date: 4/5/2019
Phone: 800-959-4464
Fax: 716-684-3823
E-Mail: imi@pcb.com
6136
Need help?
Do you have a question about the IMI SENSORS ICP 601A02 and is the answer not in the manual?
Questions and answers