Do not attempt to carry out any repairs on the C24. Refer all repairs and any service operation not described in this manual to StageSmarts or one of its authorized service partners. Do not try to carry out any repairs or unauthorized service yourself, as doing so may involve serious or lethal safety hazards.
● Do not modify the C24 in any way that is not described in this user manual. ● Do not install any parts in the C24 that are not supplied or authorized by StageSmarts. Physical safety ● Observe all locally applicable workplace safety regulations.
Introduction The C24 from StageSmarts is a 19-inch rackmount (6U) power distribution unit that represents the latest in event power distribution and is designed and manufactured to meet the latest EN norms and the highest standards. The C24 uses industrial grade (EN 60947-2) circuit breakers and is designed to withstand dusty and humid conditions.
Overview Page 8 StageSmarts C24 Series User Manual...
Page 9
Output X1 RCM: see page 17 Power input connector: see page 19 Three-phase auxiliary output X1: see page 17 Multi-pin 24-output connector modules (various types available): see page 14 Protective earth (ground) bonding terminal: see page 11 StageSmarts C24 Series User Manual Page 9...
Page 10
C24A 11 (4 x 19-pin Socapex-type main output connectors) C24A 21 (4 x 16-pin Harting-type main output connectors) C24A 31 (3 x 16-pin Harting-type main output connectors) Page 10 StageSmarts C24 Series User Manual...
Connect the PE bonding terminal to the equipotential bonding link that interconnects conductive materials in the installation (equipotential bonding is a legal requirement in some regions and is recommended in all cases to reduce the risk of electric shock). StageSmarts C24 Series User Manual Page 11...
ON position. Inspection and repair must be undertaken by a qualified electrician only. If no fault is found in the power source or source wiring but the switch disconnector still trips, contact StageSmarts for assistance. Main meter The main meter on the front panel displays all incoming voltages, currents (including Neutral current), main frequency, power factor etc.
Press again to return the display to its original state Button E ● Press once to display import energy at the panel drain input connectors ● Press again to display import reactive energy at the panel drain input connectors StageSmarts C24 Series User Manual Page 13...
Breakers 1-20 monitor Main Outputs 1-20. Each breaker has a trip current of 16 A. Breaker 1 will trip if the current draw at Main Output 1 exceeds 16 A, and so on. Page 14 StageSmarts C24 Series User Manual...
If at any time you press a breaker’s test button while power is applied to the breaker and the breaker does not trip immediately, stop using that output. Have the C24 inspected and serviced by StageSmarts C24 Series User Manual Page 15...
Page 16
StageSmarts or an authorized StageSmarts service agent as soon as possible. Do not use the output until the problem has been resolved RCBO circuit layout The C24’s 16 amp rated RCBOs on the front panel protect the main outputs on the rear panel as shown in Figure 3 when four output connectors with six channels each are fitted.
RCM trips. If it does not trip, stop using Output X1. Have the C24 inspected and serviced as soon as possible by StageSmarts or one of its authorized service agents. Figure 4. RCM on Output X1 StageSmarts C24 Series User Manual...
Page 18
2. Push and hold for 2 seconds the button marked ACTIVATED. The red indicator light in the DISABLED button will go out and the green indicator light in the ACTIVATED button will light up. Page 18 StageSmarts C24 Series User Manual...
See Error! Reference source not found.. The C24 uses 63 A-rated Harting-type connectors for power input. You can obtain a suitable 2 meter power cable with CEE and Harting-type connectors or a loose Harting-type connector from StageSmarts distributors and retailers (or directly from StageSmarts) if you order the following items: ●...
There may be overvoltage at a power input connector, or there may be a wiring fault. Disconnect the C24 from power and Investigate the problem. If you suspect that a C24 may be faulty, stop using it immediately and contact StageSmarts for assistance. C-series Interface The C24 has a communications port labelled C-SERIES INTERFACE on the rear panel.
Regularly: Check all components, connectors and cables for signs of damage or overheating. Inspect the air vents XXXXXX at regular intervals. If you see signs of dirt or dust buildup, clean the vents with a soft brush and vacuum cleaner. StageSmarts C24 Series User Manual Page 21...
13 amp BS 1363, Australian GPO or Swiss SEV 1011 depending on model) Auxiliary output channel, three-phase MCB breaker, 4-pole, 32 A* CEE connector, 5-pin RCM, 50 A, 30 mA earth leakage current Thermal Maximum ambient temperature: 45° C Minimum ambient temperature: 0° C StageSmarts C24 Series User Manual Page 23...
Page 24
Connection cable, CEE 63A 5-pole to Harting 63A, length 2m C-CON-F63A Harting 63A connector, body, insert and M40 cable gland Dimensions and weight Dimensions: 19-inch rack, 6U x 553 mm Weight: XXXXXXXXXXXXXXXXX All specifications are subject to change without notice. Page 24 StageSmarts C24 Series User Manual...