Page 2
brief introduction: The barcode device provides a complete solution for accurate, easy to use, and fast computer information system for data entry and storage. The company has another infrared automatic sensing technology. This product has "manual type" and "automatic induction type" two working modes. This product also provides a complete interface mode to accommodate the computer systems of various hosts:...
Page 3
All functions of the product are not listed in this manual, please contact the supplier for more details. All rights, including the final interpretation of this instruction manual, are reserved by the Company. * ----Default settings of the manufacturer D (Decimal) - - - -Value parameter setting (setting with decimal data code) H (Hex) - - - -Character parameter setting (complete with hexadecimal data code)
1.Basic property settings for the scanning gun 1.1 System initialization settings After system initialization, all parameters are restored to the factory setting, and the following 902000 barcode must be scanned. The respective initialization parameters are detailed in Appendix A. System initialization settings 1.2 Display the software version number When the barcode gun scan as above 000011 barcode success, the corresponding position on the computer screen will display the...
* Open Close (2) pitch / loudness adjustment When the barcode gun scans the following 002049 barcode, the setting code will enter the corresponding frequency Tone / loudness adjustment settings (range 1500-3000 Hz, default value 2700Hz) 1.4 Transmission mode (wired gun) *USBHID PS/2 UART...
Keys trigger continuous mode Pulse trigger continuous mode Continuous scan mode Flicker mode 1.6 Duration of laser under key trigger scan (D) When the barcode gun scans the following 201020 barcode, the corresponding data code will enter the corresponding setting (see Appendix C for data code) after scanning the data code, remember to scan the save code.669933 Set the single laser duration (default 3, range 1-9 in 1 second...
1.7 Laser duration under key trigger (D) When the barcode gun scans the following 201000 barcode, the corresponding data code will enter the corresponding setting for each scan (see Appendix C for data code) After scanning the data code, remember to scan the save code. Set the maximum single read time (default 2, range 0-60 in 10 seconds Not turned off for * 20 seconds...
1.9 Same barcode identification interval under continuous scanning (D) Incomplete delay is when the delay time ends when the environment changes. Complete delay means that regardless of the environment, it must be delayed for enough time to read the same bar code again.(After the barcode gun scans the following 20102 bar code, the corresponding data code will enter the corresponding setting for each scan (see Appendix C for the data code) After...
1.10 Barcode output validation level (wired gun) Some bar codes need to be confirmed repeatedly before the output to avoid the wrong code. The lower the confirmation level, the faster the barcode reading speed, the higher the error rate. The higher the confirmation level, the slower the bar code reading speed, and the lower the code error rate.
Page 12
the corresponding keyboard setting (see Appendix C for the data code) After scanning the data code, remember to scan the save code.) Table 1 Correspondi Correspo order ng bar code nding bar National keyboard National keyboard code language language Standard American 102010 102022 Dutch keyboard...
Hungarian 102020 102032 Japanese keyboard keyboard 102021 Vietnamese 102033 Italian keyboard keyboard Start the keyboard language settings * Standard American Keyboard German keyboard 1.13-character interval (D) (wired gun) Used to set the delay between characters and character of data during transmission. When the barcode gun scans the following 001022 barcode, the corresponding data code enters the corresponding delay (see Appendix C for data code) after scanning the data code, remember to scan the save code.
1.14 Serial communication option (wired gun) (1) Porter rate selection Baud rates of 1200,2400,4800, and 115200 correspond to the following barcodes, respectively. 1200 *9600 4800 115200 Porter rates of 2400,19200 and 38400 correspond to barcodes of 101001,101005 and 101006, respectively. (2)Communication handshake agreement * No handshake protocol Xon / XoFF software flow control...
(4) Stop the bit selection * 1 stop position 2 stop position (5)Check bit selection * No calibration Odd check even parity check 1.15 large / lower case lock (wired gun) Use this setting to convert alphabetic characters to a large / lowercase format.
1.16 Reverse color image reading Most bar codes are black bars and white background called positive images. Some applications may be a white strip black bottom called the reverse image. Turn on reverse color image reading Turn off reverse color image reading 1.17, full-code reading Scan allows to identify all one-dimensional bar code setting codes, and the reading function of all bar codes will be turned on.
* Open Close (3) Convert the UPC-A code to the EAN-13 code on and off. Open *Close (4) Opening and closing of UPC-A system. * Open Close 2.2 EAN-13 setting options (1) The corresponding bar code for opening and closing of reading enabling is as follows.
Allow conversion to ISBN * prohibit conversion to ISBN 2.3 EAN-8 code setting options (1) The corresponding bar code for opening and closing of reading enabling is as follows. * Open Close (2) Check the switching and closing are as follows. * Open Close 2.4 The UPC-E setting options...
(3) Convert UPC-E codes to EAN-13 and UPC-A codes. EAN-13 on UPC-A open *Close (4) Opening and closing of the UPC-E system character transmission enable. * Open Close 2.5 CODE39 code setting options (1) The corresponding barcodes for the opening and closing of reading enabling are as follows.
Page 20
(3) Full ASCII character enable on and off are as follows. Open * Close (4) The opening and closing of the start and terminator transmission enable are as follows, respectively. Open *Close (5) Convert CODE39 code to CODE32 code. Open * Close (6)...
Open * Close (9) CODE39 code reading code maximum and minimum information length setting (D) Set the Code 39 maximum information length (the default value is 80) Set the Code 39 minimum information length (the default value is 2) 2.6 CODE128 setting options (1) The corresponding barcodes for the opening and closing of reading enabling are as follows.
Set the Code 128 maximum information length (the default value is 80) Set the Code128 minimum information length (the default value is 1) 2.7 CODE-93 setting options (1) The corresponding barcodes for opening and closing of reading enabling are as follows. * Open Close (2) The barcodes corresponding to the checksum output check...
Set the Code93 minimum information length (the default value is 3) 2.8 Cross 25-yard setting options (1) The corresponding bar code for opening and closing of reading enabling is as follows. Open *Close (2) The barcodes corresponding to the checksum output check characters are as follows.
2.9 Industrial 25 yards (Industrial 25) (1) The corresponding bar code for the opening and closing of industrial 25 code reading enabling is as follows. Open * Close (2) Setting of the maximum and minimum information length of the industrial 25-code reading code (D) Set Industrial 25 maximum information length D (default value 80) Set Industrial 25 minimum information length D (default 6) 2.10 China Post Code 25 (China Post 25)
Set China Post 25 minimum information length D (default 3) 2.11 Standard Code 25 yards (Standard 25) (1) The standard 25 code reading code is as follows. Open * Close (2) Read code maximum and minimum information length setting Set Standard 25 maximum information length D (default value 80) Set Standard 25 minimum information length D (default 6) 2.12 Matrix 25 code setting options (1) The corresponding bar code for opening and closing of reading...
* Not not check Verifies but does not output a verifie Verify and output check characters (4)Matrix 25 Code reading code maximum and minimum information length setting (D) Set the maximum information length of the Matrix 25 code (default value: 80) Set the minimum information length of Matrix 25 code (default value: 6) 2.13 Kudeba code setting options (1)The corresponding bar code for opening and closing of...
* Not not check Verifies but does not output a verifie Verify and output check characters (3)The opening and closing of the start and terminator transmission enable are as follows. * Open Close (4)Codabar Code reading code maximum and minimum information length setting (D) Set the maximum information length of the Codabar code (default value: 80) Set the minimum information length of Codabar code (default value: 6)
Page 28
Open * Close (2)Check the opening and closing of transmission enable as follows. Open * Close (3)The opening and closing of MSI-Plessy code reading enable are as follows. Open *Close (4)The MSI code calibration mode * No check Mode 10 check Mode 11 check Mode 10 Remode 10 check Mode 10 Remode 11 check...
Set the MSI maximum information length (default value of 80) Set the MSI minimum information length (default value of 6) 2.15 CODE 11 code setting options (1) The corresponding bar code for opening and closing of reading enabling is as follows. Open *Close (2) The opening and closing of the verification transmission...
C, K verification (4) CODE11 code reading code maximum and minimum information length setting (D) Set CODE11 maximum information length (default value 80) Set the CODE11 minimum information length (default value 3) 2.16 RSS code setting options (1) The opening and closing of the standard RSS code (RSS-14) are as follows.
Open *Close 3.Advanced setting options for the barcode 3.1 Add a prefix / suffix (H) (1) Add a prefix Turn off the custom prefix Turn on the custom prefix Set the custom prefix content H (up to 10 characters) (2) Add the suffix Close the custom suffix Open the custom suffix Set the custom suffix content H (up to 10 characters)
ding ding ding code code code name name name Industry 25 EAN-13 Matrix-25 yards MSI a sign or Qualified type EAN-8 object indicating RSS code number Expansion-type UPC-E CODE11 RSS code CODE128 UPC-A Standard RSS CODE93 codes CODE39 CODE-32 Kudeba code China post Cross 25 Standard 25...
Page 33
Local setting: the code type can be specified for a specific user, and refer to table 3 below for the specific code type. corres corres corres corres pondin pondin pondin pondin code code code type code type code type code code name name...
Page 34
In the barcode output, the comprehensive output will be set according to the local and global user, and the judgment conditions are as follows: If a certain type of editing (such as adding characters before the barcode) has a local setting, but also a global setting, the output is only output in a local setting way.
Page 35
When this setting barcode is generated with the barcode generation software, the selection code class is CODE128 and the data source is ^ 302000000003123. Reset barcode production: 0B200 00 Leading command for global / local code (2) Filter out the same character before the barcode For example, if the resolved barcode data is AAA1234 and the specified character is A, the output result is 1234.
Page 36
As long as the specified character appears in the barcode data, filter out the character, and output Other data. For example, if the barcode data is A12A34AA56789A and the specified character is A, the output is 123456789. Barcode production: 02300000 02 7 The leading command specifies a character, and up to the ASCII Visible characters with a global / local substitution value of 32...
Page 37
Reset barcode production: 0B240 01 Leading command for global / local code (B) Add the characters from the end Function is similar to the above setup except for the added position in the tail. Bar code production: 02500000 08 4 ABCD The leading command specifies the character length to be with Global / local code previously, ranging from 32 to 126 Length of character to be added, range from 1 to 9 visible ASCII...
Page 38
Delete characters from scratch, from tail, and from the middle. (a) Remove characters from scratch Starting from the head of the barcode, delete the specified number of characters. For example, if the barcode is ABCD1234 and the number of deleted characters specified is 4, output 1234.
Page 39
The leading command Specify the word to delete Number of global / local codes, ranging from 1 to 50. Specify a location, ranging from 001 to 250 Reset barcode production: 0B290 04 The leading command Global / Local code (7) Keep the barcode for the specified number of digits This setup function is to retain only part of the barcode, regardless of the barcode length.
Page 40
(8)replace The character replacement function is to replace the specified characters with the target characters. For example, when resolving the bar code to 1234ABCD90, now to replace the ABCD is 5678, then the output 1234567890. Barcode production: 02A00000 05 4 ABCD 5 56789 The character replaced by the leading command, is long The global / local code degree agrees with the length specified previously...
Page 41
Barcode production: 02B00000 00 $0D $0A $81 The leading command Prefix suffix characters, specific meaning Global / Local code Refer to Appendix B. Front suffix indicator The above command means: add return, line change and F2 before all barcodes. Reset barcode production: 0B2B0 00 Leading command for global / local code (B) Add the suffix...
Appendix A (ASCII coding table) 0x00~0x3F ASCII ASCII control control ASCII hexadeci ASCII hexadeci characte characte price price r ASCII r ASCII (space) " &...
Page 43
< > 0x40~0x7F ASCII ASCII control control ASCII hexadeci ASCII hexadeci characte characte price price r ASCII r ASCII 、...
Appendix B (Data code) Data '0' Data '1' Data "2" Data "3" Data "4" Data "5" Data "6" Data "7" Data "8" Data "9" Data "A" Data "B" Data "C" Data "D" Data "E" Data "F"...
Page 46
Read the "save" code parameter input, confirm to save...
Page 47
Wireless MCU function setting code Inventory function Settings Data is not missing from the Ordinary mode Inventory mode mode (Immediate upload of data) (The storage mode) (Instant upload of data + %%ALLPT-SET %%ALLMEM-SET storage mode) %%ALLAEM-SET The total number of scans is shown clear data Data upload...
Page 48
Show the remaining power %%Batt Transport mode switching settings Bluetooth mode In 2.4G mode Paired settings One key pairing %%EZPair 2.4G one-button pairing method: first scan the scanner "one-button pairing" to set the bar code, wait for the scanner "di", "" di "and" di "sound, then insert the receiver into the computer USB interface (note: after successful pairing, the scanner"...
Page 49
Open the decoding sound Close the decoding sound Bluetooth name modification setting Bluetooth name factory default "scangun", if you need to set the Bluetooth name steps are as follows: 1. Change the Bluetooth name needs to be changed in Bluetooth mode 2.
Page 50
Parameter value bar code %%ALL*_0 %%ALL*_1 %%ALL*_2 %%ALL*_3 %%ALL*_4 %%ALL*_5 %%ALL*_6 %%ALL*_7 %%ALL*_8 %%ALL*_9 Standby time setting (default: 20 seconds) Set up method: scan the desired standby time barcode with the wireless barcode scanner. Don't shut down 20 Seconds * %%ALLTIMSET %%ALLTIM00 30 Seconds...
Page 51
10 Minutes 20 Minutes %%ALLTIM05 %%ALLTIM06 Wireless Function Recovery Factory Receiver version number (PAN108-V1.220230708) Scan gun version number (PANBridgeV1.020230612) keyboard layout Type 1: US Type2: Belgium Type 3: Brazil, Type 4: Canada Type 5: Czechoslovakia 6: Denmark Type 7: Finland, 8th type: France Type 9: Greece 10: Hungary...
Page 52
Type 11: Italy Type 12: The Netherlands Type 13: Norway Type 14: Portugal Type 15: Russia Type 16: Spain Type 17: Sweden Type 18: Switzerland Type 19: Turkey 1, Type 20: Turkey 2 Type 21: Germany Type 22: Japan...
Need help?
Do you have a question about the 351023 and is the answer not in the manual?
Questions and answers