Product Data
Electrical Data
Supply voltage
Max. Voltage ripple
Current consumption
Max. output load (Q1)
Reverse polarity protected
Short circuit protected
Inductive load protection
Environmental Data
Light immunity @5º incidence
Temperature, operation
Sealing class
Marking
Available Models
Model
SST 01-10-xxx-xxx-05-H-1D1-0.5-J5
Transmitter
SST 01-10-xxx-xxx-10-H-1D1-0.5-J5
SST 01-10-xxx-xxx-20-H-1D1-0.5-J5
SSR 01-10-xxx-xxx-05-H-IO-0.5-J5
Receiver
SSR 01-10-xxx-xxx-10-H-IO-0.5-J5
SSR 01-10-xxx-xxx-20-H-IO-0.5-J5
Connection
Wiring Diagrams
SST and SSR 5 pole M12 male connector
Transmitter Model
SST 01-10-xxx-xxx-xx-H-1D1-0.5-J5
Website: www.telcosensors.com
E-Mail:
info@telcosensors.com
Made in Denmark
SST (Transmitter)
SSR (Receiver)
12 – 30 V dc
15 % (within supply range)
100 mA (RMS)
50 mA
-
100 mA
Yes
Yes
-
Yes
> 100.000 lux
-30 to + 60 ºC
IP 67
Beam spacing
Sensing Range
5 mm
10 mm
20 mm
5 mm
10 mm
20 mm
5 pin, M12
Black wire
Black wire
connected to (-)
not connected
connected to (+)
not transmitting
transmitting
This device is not to be used for Personnel Protection in Machine
!
Guarding Safety applications. This device does not include the self-
checking redundant circuitry necessary to allow its use in personnel
machine guarding stand-alone safety applications.
EN
Installation & Adjustments
Installation
The light curtain is configured by the PC program 'IO-Link Device Tool V5.1' from TMG,
described in the following pages. Before using it, check the power supply complies with
electrical data.
1
Mount the transmitter (SST) and receiver (SSR) facing each other and correctly aligned.
Wire the sensor according to the wiring diagram.
Notice that the pin 3 on the SSR and the pin 3 on SST (blue wires) must be connected to
2
a common GND (–).
Make sure the SSR output load does not exceed 100 mA.
3
Check for correct wiring before turning power on.
When the power on indicator (green LED) on SSR and SST is on, the system is
4
operating.
The position of the receiver and transmitter must not be changed after power-up. The
5
light curtain is only intended for static applications.
SST Test Input
10 m
The transmitter SST can be externally disabled and enabled via the black control wire for test
purposes. When the transmitter is disabled the action of the receiver corresponds to breaking
0 m – 4 m
all beams.
or
1 m – 10 m
Indicators
SSR
SSR
SSR & SST
Troubleshooting
Probable Reason
1. Symptom: Status indicator (Red LED) on SSR is constant on.
SST has no power.
SST & SSR white, grey and blue wires are
not connected correctly.
2. Symptom: Output indicator (Yellow LED) on SSR is flashing.
Severe electrical interference.
Severe ambient light.
Cross talk from another light curtain or
photo sensor
Black wire
Cross talk from a nearby HF strip light
transmitting
3. Symptom: Digital outputs do not response when IR beams are obstructed.
One or more beams are blocked, or the
rails are out of sensing range.
The test input on SST is activated
Outputs are not configured for simple
detection of obstructions
Warning
Red LED
Status indicator
Yellow LED
Follows state of Digital Output 1
Green LED
Power on indicator
Corrective Action
Check supply and supply cable to the SST
Connect the wires.
Separate SSR and SST supply cable from high
voltage cables.
Swap position of SSR and SST.
Swap position of SSR and SST.
Swap position of SSR and SST or remove the
strip light.
Remove obstruction or reduce the distance
between the rails.
Remove SST pin 4 (black wire) from ground.
If needed, factory reset the SSR using the
Parameter tab in the PC program '
V 1.4 Part Number: 0666220975
Telco A/S reserves the right to make changes without prior notice
June 2023 edition
Page 1 of 4

Advertisement

loading
Need help?

Need help?

Do you have a question about the Space Scan Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Telco Space Scan Series

  • Page 1 This device is not to be used for Personnel Protection in Machine Guarding Safety applications. This device does not include the self- Made in Denmark Telco A/S reserves the right to make changes without prior notice checking redundant circuitry necessary to allow its use in personnel Page 1 of 4...
  • Page 2 Connect the TMG-USB IO-Link Master USB-adaptor to the USB-port of the PC and to the cable of the SS 01-IO. Please contact to your Telco Sensors supplier for the IODD files and TMG IO-Link Device Tool. Install the TMG IO-Link Device Tool V5.1.1-5122 SE – Setup file and run the program.
  • Page 3 This device is not to be used for Personnel Protection in Machine Guarding Safety applications. This device does not include the self- Made in Denmark Telco A/S reserves the right to make changes without prior notice checking redundant circuitry necessary to allow its use in personnel Page 3 of 4...
  • Page 4 This device is not to be used for Personnel Protection in Machine Guarding Safety applications. This device does not include the self- Made in Denmark Telco A/S reserves the right to make changes without prior notice checking redundant circuitry necessary to allow its use in personnel Page 4 of 4...

This manual is also suitable for:

Ss 01-io