Chapter 1 Table of contents Chapter 1 Table of contents Cover Chapter 1 Table of contents Chapter 2 Declaration of conformity Chapter 3 Specifications Chapter 4 General specifications 4.1 Translation 4.2 Copyright 4.3 General descriptive names 4.4 Safety instructions 4.4.1 Use of the hazard warnings 4.4.2 General safety instructions 4.5 Overview 4.6 Intended use...
Page 4
7.5 Recharging power supply units Chapter 8 Operating elements 8.1 Status LED Chapter 9 Maintenance 9.1 General maintenance 9.2 Fuse replacement Chapter 10 Removal/disposal Chapter 11 Troubleshooting and repair 11.1 General problems Chapter 12 Spare parts and accessories 12.1 Compatible power supply units Chapter 13 Document history Chapter 14 Glossary Chapter 15 Contact information...
Chapter 3 Specifications Chapter 3 Specifications Charging voltage max. 4,17 V Charging current max. 2,5 A Input voltage range 90...264 VAC Input current 450 mA(rms) @90 VAC Input frequency range 47...63 Hz Operating temperature 0...+40 °C Storage temperature -20...+70 °C Air humidity 10...90 % RH Protection class IP40 Dimensions (WHD) 125 x 94 x 26 mm (without power supply unit) Weight 250 g (incl.
Chapter 4 General specifications Chapter 4 General specifications The information in this manual has been compiled with great care and to the best of our knowledge. The manufacturer, however, assumes no liability for any incorrect specifications that may be provided in this manual.
4.4.1 Use of the hazard warnings DANGER: Indicates a potential or threatening hazardous situation that will result in death or serious injuries if not avoided. WARNING: Indicates a potential or threatening hazardous situation that can result in death or serious injuries if not avoided.
Chapter 4 General specifications 4.5 Overview Top of the PSU Charger Left side of the PSU Charger 1 Button (reserverd for extension) 4 Connector port for older generations of the plug-in power supply unit 2 Connector port for the PSU to be charged 5 DC hollow plug for connecting the plug-in power supply unit included in the scope of supply 3 Status LED...
4.7 General product information This is a charger suitable for the following power supply units of the PSU family (Power Supply Unit): PSU413D+ AP (300524) PSU413D AP (300525) In addition to the current state of charge (SOC), the controller of the PSU Charger also reads additional information required for the charging process (e.g.
Chapter 4 General specifications 4.9 Installation of spare and wear parts Be advised that spare and accessory parts that have not been supplied by the manufacturer have also not been inspected or approved by the manufacturer. The installation and/or use of such products can possibly have a negative impact on the specified constructional properties of the device.
For safety and warranty reasons, all internal work on the instruments beyond from that involved in normal installation and connection, must be carried out only by qualified Microtronics personnel or persons or companies authorised by Microtronics .
Chapter 5 Functional principle Chapter 5 Functional principle Functional principle Plug-in power supply (included in the scope of supply of 300697) Compatible power supply unit e.g. PSU413D+ AP (300524) PSU Charger Functions and components Plug-in power supply Plug-in power supply that can provide at least 12W at an output voltage of 12 V .
Support & Service Centre (see "Contact information" on page 37). The return shipment of the PSU Charger must occur in the original packaging and with freight and insurance paid to Microtronics Engineering GmbH (see "Contact information" on page 37). Insufficiently cleared return shipments will otherwise not be accepted! Rev.
Read this manual carefully and completely in order to ensure the proper functioning of the PSU Charger Contact Microtronics Engineering GmbH(see "Contact information" on page 37) if anything is unclear or if you encounter difficulties with regard to installation, connection or configuration.
7.5 Recharging power supply units Important note: Ensure setup is completed correctly. Comply with existing legal and/or operational directives. Improper handling can cause injuries and/or damage to the devices. Further safety instructions are provided in "Safety instructions" on page 9. The location for the PSU Charger must be chosen according to certain criteria.
Page 21
Chapter 7 Initial Start-Up 3. Plug the power supply unit into the PSU Charger . The Power Supply Unit is designed in such a way that it cannot be plugged in the wrong way around. The status LED should then start flashing green, indicating that the PSU is recharging.
Chapter 8 Operating elements Chapter 8 Operating elements Operating elements 1 Button (reserverd for extension) 2 Status LED 8.1 Status LED The status LED is used both to display error codes and to indicate the current operating state. In the event of an error, the error codes listed in the following table are displayed every 5 seconds.
Chapter 9 Maintenance Chapter 9 Maintenance Important note: To prevent any damage to the device, the work described in this section of the instructions must only be performed by qualified personnel. The device must be deenergised before any maintenance, cleaning and/or repair work. 9.1 General maintenance Regularly check the PSU Charger for mechanical damage.
Logo of the EU WEEE Directive This symbol indicates that the requirements of Directive 2012/19/EU regarding the scrap disposal of waste from electric and electronic equipment must be observed. Microtronics Engineering GmbH supports and promotes recycling and environmentally friendly, separate collection/disposal of waste from electric and electronic equipment in order to protect the environment and human health.
Chapter 11 Troubleshooting and repair Chapter 11 Troubleshooting and repair 11.1 General problems Problem Cause/Solution The device does not respond (status Check the cable connections (see "Recharging power LED always off). supply units" on page 20) Fuse defective. Return device to manufacturer for fuse replacement (see "Return"...
Chapter 12 Spare parts and accessories Chapter 12 Spare parts and accessories 12.1 Compatible power supply units Description Quantity Order number PSU413D+ AP 300524 PSU413D AP 300525 Rev. 01...
Chapter 14 Glossary Chapter 14 Glossary App centre Area of the myDatanet server for the installation and management of the IoT apps. The app models that serve as a basis for the IoT apps are obtained via the rapidM2M Store . When installing an IoT app on the myDatanet server the default settings defined when developing the app models are initially applied.
Page 36
rapidM2M timestamp Depending on the required accuracy, one of two special encodings can be used for the time stamp in rapidM2M. If the accuracy requirements are moderate, the "stamp32" data type (seconds since 1999- 12-31 00:00:00 UTC) can be used. If a higher accuracy is required, the "stamp40" data type (1/256 seconds since 1999-12-31 00:00:00 UTC) can be used.
Need help?
Do you have a question about the PSU413D+ AP and is the answer not in the manual?
Questions and answers