Bosche PS SST Operating Manual

Bosche PS SST Operating Manual

Package scale

Advertisement

Quick Links

BOSCHE
Package scale
PS SST
Operating manual
- Translation of the original -
(keep for future use)
Last revised: 2024-04-15

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS SST and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bosche PS SST

  • Page 1 BOSCHE Package scale PS SST Operating manual - Translation of the original - (keep for future use) Last revised: 2024-04-15...
  • Page 3 Email info@bosche.eu www.bosche.eu This manual has been created on: 2024-04-15 Copyright Bosche GmbH & Co. KG retains all rights for this document. Copying, disclosure to third parties or use of its contents are forbidden without our express approval © 2024...
  • Page 5 However, this means that there is no obligation to carry out retrospective modifications in this connection. Danger Before using the Package scale PS SST, you must have read and under- stood the operating instructions and the safety regulations that they contain.
  • Page 6: Table Of Contents

    Table of contents Package scale PS SST Table of contents 1 Safety ........................4 1.1 For your safety ....................4 1.1.1 General ....................4 1.1.2 Safety symbols in this manual ............... 4 1.2 Intended use ....................5 1.3 Inappropriate use .................... 5 1.4 Obligations of the owner/user .................
  • Page 7 Package scale PS SST Table of contents 7 Troubleshooting ....................19 7.1 In the event of a malfunction ................. 19 7.2 Error messages of the scales................ 19 7.3 Customer service contact data..............19 7.4 Information for the contact to the customer service ........20 8 Technical data ....................
  • Page 8: Safety

    1 | Safety Package scale PS SST Safety This chapter warns against possible risks when handling the device. The information for detection of risks contained in this chapter is intended to allow the save and correct operation. It is important to read and adhere to this operating manual and particularly this chapter prior to operating this device.
  • Page 9: Intended Use

    Safety | 1 Intended use The package scale PS SST is used to determine the weight of loads. Any further use is considered as not in accordance with the intended use. The manufacturer does not assume any liability for resulting damage.
  • Page 10: Description Of The Dangers

    The BOSCHE company offers a restricted warranty for components, which became faulty due to strain or material faults. The warranty starts with the date of delivery. The BOSCHE company retains the right to repair or replace components. Repair work executed during the warranty period will not extend the period of warranty.
  • Page 11: Description

    Package scale PS SST Description | 2 Description Construction Item Designation LCD display with 2 m spiral cable. Connection for power cable Stainless steel weighing plate (removable) RS 232 interface Battery case below the platform (6 x AA Mignon, not included) Wall mount Control panels for the various functions of the unit.
  • Page 12: Legend For The Weighing Value Display

    2 | Description Package scale PS SST 2.1.1 Legend for the weighing value display Keybord overview The keyboard, consisting of pressure point keys with acoustic signal, is water- protected. Taste Bedienerebene Switching the scale on or off Holds the display value for 120 seconds.
  • Page 13: Display

    Package scale PS SST Description | 2 Display The LCD displays are equipped with background lighting. 2.3.1 Display overview Note The arrows indicate the current status. Battery warning Hold-function (if the symbol is shown, the batteries must be changed) Last revised:...
  • Page 14: Transport, Commissioning/Start-Up And Tests/Inspections

    Vibration schützen! Gerät sauber halten! Instabile Spannungs- Feuchtigkeit meiden! quellen meiden! Note Ensure that a 240 V AC voltage supply is available on the installation site (unless operation with rechargeable batteries is intended). Last revised: BOSCHE Weighing Systems Page 10 2024-04-15...
  • Page 15: Installation Work

    Package scale PS SST Transport, commissioning/start-up and tests/ Installation work • Transport the package scale carefully, load cells are sensitive electromechanical sensors. • Place the package scale on a level and stable surface. • Plug the mains cable into the socket at the back of the scale and the mains adapter into the socket.
  • Page 16: Operation

    4 | Operation Package scale PS SST Operation Attention A warm-up time of 15 minutes stabilises the measured values after switching Attention If the load on the scale exceeds the weighing range, the following message "Err - 0" appears on the display.
  • Page 17: Weighing

    Package scale PS SST Operation | 4 Weighing 4.5.1 Simple weighing If the weight of the weighing sample will exceed the set weighing range the fol- lowing message is displayed: Please remove the load from the platform, immediately to avoid damage.
  • Page 18: Tare Weighing

    4 | Operation Package scale PS SST Tare weighing 4.6.1 Determination of tare by weighing The weight of each weighing container can be removed by pressing the “Zero/ Tare“ key, so that the net weight is displayed.. Tare Clear tare...
  • Page 19: Auto Off

    Package scale PS SST Operation | 4 Auto off Note The automatic switch-off function should be active if the scales are operated with batteries. If the scales are not used, they switch off after approx. 3 minu- tes. • Switch off the scale with the key •...
  • Page 20: Calibration

    5 | Calibration Package scale PS SST Calibration Calibration with the maximum load Note To achieve accurate weighing results, calibrate the scale with the maximum load. • Switch off the scale with the key • Press and hold the key •...
  • Page 21 Package scale PS SST Calibration | 5 • Change the calibration weight using the keys - For example, “C0060“ appears on the display for a calibration weight of 20 kg. • Press the key - “d 0.02" (division) appears on the display.
  • Page 22: Maintenance And Care

    Attention Replace defective or damaged cables or cable glands as a unit. Maintenance, servicing Only trained service engineers who have been authorised by Bosche are allo- wed to open the package scale. Danger Before opening the package scale, you must ensure that it has been safely deenergised and disconnected from the mains.
  • Page 23: Troubleshooting

    If any other malfunctions or error messages occur, please switch off the scales and after a short while on again. If error messages occur again, please contact the Bosche customer service. Customer service contact data Bosche GmbH & Co. KG...
  • Page 24: Information For The Contact To The Customer Service

    7 | Troubleshooting Package scale PS SST Information for the contact to the customer service Owner/user Specifications Name of your company Name of a contact person Contact data Telephone Email Product Specifications Model name Serial number Type key Date of purchase...
  • Page 25: Technical Data | 8

    Package scale PS SST Technical data | 8 Technical data Technical data Feature Value / Unit Total dimensions (W x H x D) of the 330 x 60 x 320 mm weighing platform Weight without batteries approx. 3.8 kg Power supply (external) 9 VDC / 240 VAC, 300 mA by external mains adapter.
  • Page 26: Declaration Of Conformity

    EN 61000-4-3:2011 EN 61000-4-4:2012 EN 61000-4-5:2014 EN 61000-4-6:2014 2011/65/EU RoHS EN IEC 63000:2018 Unterzeichnet für und im Namen von Bosche: Damme, 25.11.2021 Geschäftsführer • Managing Director Directeur général • Directeur • Director general Last revised: BOSCHE Weighing Systems Page 22...
  • Page 28 BOSCHE GmbH & Co. KG 05491 999 689 0 Reselager Rieden 3 Fax 05491 999 689 9 49401 Damme www.bosche.eu Germany info@bosche.eu...

This manual is also suitable for:

Ps sst 60Ps sst 100Ps sst 150Ps 60 sst

Table of Contents