Installation Instructions
Each Multi-Pack AC Adapter is designed to power up to four (4)
ESD-200/250/300/350 Soap dispensers.
Step 1
Disconnect and remove the battery packs from battery powered Model
ESD-250/350 Soap Dispensers, if applicable.
Step 2
Determine the mounting location for the Multi-Pack Adapter Box and AC Wall
Adapter. Make certain that cable lengths of the AC Adapter (6 ft/1829 mm) and
Wire Assemblies (5 ft/1524 mm) will reach their respective connections.
Step 3
Attach the Multi-Pack Adapter Box to the desired surface using the Wall
Mounting Anchors or double-sided Adhesive Pad.
Step 4
Plug the Three-prong Connector end of the Wire Assembly into one of the
Multi-Pack Adapter Box receptacles. Connect the remaining end with the
Bayonet Connector into the ESD-200/250/300/350 Soap Dispenser. Be sure to
secure the Bayonet power connection with the thumbnut. Follow the previous
instructions for connecting up to three (3) additional ESD-200/250/300/350
Soap Dispensers.
Step 5
Plug the AC Wall Adapter into the 120 VAC Wall Receptacle.
The ESD-200/250/300/350 Soap Dispensers are now ready for operation.
If further assistance is required, contact your nearest Sloan Representative
office or the Sloan Installation Engineering Department at:
1-888-SLOAN-14 (1-888-756-2614)
Important: The Multi-Pack AC Adapter is not compatible with any Sloan Optima
or Optima Plus faucets.
Copyright © 2006 SLOAN VALVE COMPANY
with
The information contained in this document is subject to change without notice.
INSTALLATION INSTRUCTIONS
MULTI-PACK AC ADAPTER FOR
ESD SERIES SOAP DISPENSERS
ESD-236 and ESD-237
Multi-Pack AC Adapter
Item # Part #
Description
1.
ESD-236
Multi-Pack Adapter Box (includes Item #'s 2 and 3)
Physical Dimensions: 5" (127 mm) Wide x 3-3/8" (86
mm) High x 2-1/4" (57 mm) Deep
2.
AC Wall Adapter with 6' (1829 mm) Cord (included with
Item #1)
Physical Dimensions: 3-1/8" (79 mm) Wide x 2-1/8"
(54 mm) High x 1-1/2" (38 mm) Deep
3.
Mounting Kit, includes two (2) Wall Anchors with
Screws and one (1) 4½" (114 mm) x 3" (76 mm)
Adhesive Pad (included with Item #1)
4.
ESD-237
Wire Assembly with Bayonet Connector (5' /1524 mm)
SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131
Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380
Code No. 0816497
Parts List
www.sloanvalve.com
Printed in the U.S.A. 11-06
Rev. 0 (11/06)

Advertisement

loading
Need help?

Need help?

Do you have a question about the ESD-236 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Sloan ESD-236

  • Page 1 ESD-237 Wire Assembly with Bayonet Connector (5’ /1524 mm) Important: The Multi-Pack AC Adapter is not compatible with any Sloan Optima or Optima Plus faucets. The information contained in this document is subject to change without notice. SLOAN VALVE COMPANY • 10500 Seymour Avenue • Franklin Park, IL 60131 Phone: 1-800-9-VALVE-9 or 1-847-671-4300 •...
  • Page 2 (1 year for special finishes) from date of purchase. During this period, Sloan Valve Company will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s cost, and this shall be the sole remedy available under this...
  • Page 3: Installation

    1/8” (3 mm) COUNTER FLANGE Model ESD-20080/25085/30880/35187 Soap Dispenser and Faucet Combinations INSTALLATION When the ESD Soap Dispenser is packaged with a Sloan ETF-80, ETF-880, The ESD-200/250/300/350 Soap ETF-299-A 2 PIECE SOAP FAUCET EBF-85 or EBF-187 Faucet for installation on a 4” centerset sink, a special...
  • Page 4 ESD-200, ESD-250, ESD-300 & ESD-350 Soap Dispenser Location Template IMPORTANT: READ THIS BEFORE USING TEMPLATE. If this Installation Instructions was printed from a PDF file to a computer printer, make certain that the template is the correct size before using. Measure to make certain that the 1-1/2"...
  • Page 5 1 - Install Spout Slide Rubber Gasket onto Brass Shank making certain that hole in Gasket is positioned over Spring Pin in Base of Spout (where applicable). Guide Brass Shank and Sensor Cord through hole in counter. Position Spout to direct soap into sink. RUBBER GASKET Guide Sensor Cord through Flange Nut.
  • Page 6 4 - Connect AC Power (Models ESD-200 & ESD-300 Only) MOTOR ASSEMBLY Plug transformer into 120 VAC CORD Connect the power cord from the wall receptacle, activating the transformer by inserting then soap dispenser. screwing clockwise into inlet on top of motor assembly.
  • Page 7: Troubleshooting Guide

    ESD-35187 Combination Soap Dispenser and Faucet The information contained in this document is subject to change without notice. SLOAN VALVE COMPANY • 10500 SEYMOUR AVENUE • FRANKLIN PARK, IL 60131 Phone: 1-800-9-VALVE-9 or 1-847-671-4300 • Fax: 1-800-447-8329 or 1-847-671-4380 • www.sloanvalve.com Copyright ©...

This manual is also suitable for:

Esd-237