Heliotherm Silent Source 60 Installation Instructions Manual
Heliotherm Silent Source 60 Installation Instructions Manual

Heliotherm Silent Source 60 Installation Instructions Manual

Outdoor air evaporator
Table of Contents

Advertisement

Quick Links

Installation Instructions
Outdoor air evaporator
Silent Source 60 | 80 | 120
Translation of the original instruction manual
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Silent Source 60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Heliotherm Silent Source 60

  • Page 1 Installation Instructions Outdoor air evaporator Silent Source 60 | 80 | 120 Translation of the original instruction manual...
  • Page 2: Table Of Contents

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Table of Contents EC DECLARATION OF CONFORMITY ................5 About this document ..................6 Document purpose ........................6 Handling of document .......................6 Symbols and means of representation ..................6 1.3.1 Warning notice ..........................6 1.3.2...
  • Page 3 Dimensioned drawing Silent Source 80 ...................34 20.1.3 Dimensioned drawing Silent Source 120 .................35 20.1.4 Dimensional drawing aluminium shaft for Silent Source 60 ............36 20.1.5 Dimensional drawing aluminium shaft for Silent Source 80 / 120 ..........37 20.1.6 Shaft plan Silent Source 60 .....................38 20.1.7...
  • Page 4 Heliotherm is not bound to any form of liability where these instructions are not explicitly followed when installing the heat pump system, upon onset of operation and during maintenance and according to the applicable warranty and warranty provisions. Heliotherm reserves the right to make changes to specifications without previous no- tice.
  • Page 5: Ec Declaration Of Conformity

    EC DECLARATION OF CONFORMITY We declare under sole responsibility that the following heat pump unit device corresponds with the following Council of Directives standards in alignment to the regulations of the EU Member States. This declaration loses its validity, upon any changes made to the heat pump unit device without a previous written consent agreement from the manufacturer.
  • Page 6: About This Document

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 About this document Document purpose This manual is part of the product and contains all the necessary information for the safe performance of the following activities: - Transport - Setting up for installation...
  • Page 7: Revision And Validity

    Version 4 27.08.2020 Tab. 2: Revision history These instructions are valid for the following products: Type Description Article number Silent Source 60 HPS60 Silent Source 80 HPS80 Silent Source 120 HPS120 Tab. 3: List of products to which this document is applicable Applicable documents Follow all operating instructions that come with the heating system components.
  • Page 8: Safety

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Safety Intented use The outdoor air evaporator is soley for the manufacturer‘s intended purpose of evaporating refrigerant through energy exchange with the ambient air. Should the unit be used in any other way or beyond its intended use, it will be considered contrary to provisions and regulated use.
  • Page 9: Installation Qualification-, Commissioning, Maintenance And Service Staff

    Installation qualification-, commissioning, maintenance and service staff The outdoor evaporator must be installed by an authorized specialized company, commissioned and serviced. In addition, their employees are required to attend and have completed the Heliotherm product training. It is necessary to ensure that the process of installation, commissioning, maintenance and service per- sonnel reads and understands this manual, the heat pump‘s operating manual and has understood all...
  • Page 10: Commissioning And Continuous Operation

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Sharp glass splinters if glass is damaged Risk of injury! Never lean side panels against edges or corners! CAUTION Never set side panels with the glass surface face down on the floor! Do not step on side panels lying on the floor.
  • Page 11: Coming In Contact With The Refrigerant

    Coming in contact with the refrigerant 2.6.1 Inhaled refrigerant Immediately bring the affected person outside in the fresh air! Respiratory failure/ severe exposure: Administer first aid measures! Contact a doctor! Keep at hand safety data sheet! 2.6.2 Skin and eye contact with refrigerant Remove contaminated clothing! Thoroughly rinse out eyes or affected body parts for at least 15 minutes with water! Contact a doctor!
  • Page 12: Product Description

    -25 °C. 4.2.2 Functions The outdoor air evaporator is an essential component of the Heliotherm air/water heat pump. It is installed outdoors making the ambient air usable as the energy source, connected to the corresponding indoor heat pump unit via split lines.
  • Page 13: Outdoor Evaporator Assembly

    A thermodynamic phase transition takes place in the outdoor air evaporator. Liquid refrigerant is distribut- ed by means of a venturi orifice to several fin packet circuits. During the flow through the line distribution, the refrigerant withdraws heat from its environment proceeding to the evaporating process. Thus always having new aerial ‘energy rich’...
  • Page 14: Delivered Items

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Delivered items Basic unit Damaged / broken glass Risk of injury! Never lean the side panels with the outer side on a corner or sharp edged surface! CAUTION Never set side panels with the outer side facing down on the floor! Do not step on side panels lying on the ground! Replace damaged panels immediately.
  • Page 15: Planning The Installation

    Planning the installation Unit dimensions Condition Silent Source 60 Silent Source 80 Silent Source 120 Packaged 1.350 x 1.200 x 1.200 1.400 x 1.200 x 1.200 1.637 x 1.200 x 1.200 Unpacked incl. cover 1070 x 890 x 850 1.260 x 1.020 x 960 1.506 x 1.050 x 1.140...
  • Page 16: Storage

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Storage The outdoor air evaporator may only be stored in its original packaging in a dry place. Where it should be vertically positioned. It is not allowed to put other objects on the heat pump! The following climatic condi-...
  • Page 17: Transport

    Transport Upon delivery the outdoor air evaporator must be immediately inspected for any visible damage which is to be reported immediately to the shipping company. Tipping over of the outdoor air evaporator. Risk of injury/crushing! CAUTION Caution should be taken when transporting the device. Wear personal protective equipment.
  • Page 18: Setting Up For Installation

    Silent Source 60 / 80 / 120 Setting up for installation Heliotherm recommends that customers should contact the local authorities during the planning phase in regards to any regional regulations that should be observed when installing the heat pump / outdoor air evaporator unit.
  • Page 19: Setting Up The Outdoor Air Evaporator

    If the aluminum shaft has been sunk into the ground in accordance with regulations and backfilled cor- rectly, it is to be filled with gravel. It is important to ensure that any condensation water can drip down freely from the plate pack and that there is enough space between the plate pack and the gravel surface consists.
  • Page 20 INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Lift the outdoor air evaporator from the pallet. Place the outdoor air evaporator on the alumi- num base. Position the outdoor air evaporator so that it can be positioned through the holes with the blind rivet nuts and screwed to the aluminum base.
  • Page 21: Concrete Foundation

    The condensate water drips down into the shaft. To en- sure that the water can seep into the ground, the base must be assembled according to the Heliotherm instructions and guidelines. This includes using in the excavating frost protection gravel beneath the base.
  • Page 22: Connections

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Connections 10.1 Outdoor evaporator electrical connection Live parts in the device. Personal injury by electric shock! All electrical work may only be performed under voltage free wor king conditions and carried out by authorized and trained qualified electri-...
  • Page 23: Split Line Connections

    10.2 Split line connections Leaky refrigerant Frostbite / cold burns! Connecting tubes may only be laid and installed by an authorized and WARNING trained specialists. Pipes must be laid free of tension. Check that all lines are completely sealed. Fig. 13: Split line connections Pos.
  • Page 24: Commissioning The Heat Pump

    Any breach of this instruction and procedure automatically cancels provision of any warranty claim. The outdoor air evaporator commissioning is described in the Heliotherm air/ water heat pump installation instruction manual. Error The Silent Source Series outdoor air evaporator is a product of highest quality standard, which is designed for a trouble-free operation for many years.
  • Page 25: Maintenance

    Maintenance Live parts in the device. Personal injury by electric shock upon contact with live parts! All electrical work may only be carried out in a voltage-free state and DANGER by authorized and trained electricians! Ensure a voltage-free condition by releasing the fuse in the safety box, secure before restarting! Switch off the device on all poles! As a rule, the outdoor air evaporator is a maintenance-free heating system, although an annual inspec-...
  • Page 26: Maintenance Check

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 13.4 Maintenance check 13.4.1 Care Improper cleaning. Heat pump damage! To clean the unit: never use acids, chlorides, soda, or cleaning agents – NOTICE containing sand, as these cleaners will cause sustainable damage to the surface.
  • Page 27: Repair

    Repair Live parts in the outdoor air evaporator. Personal injury by electric shock upon contact with live parts! All electrical work may only be carried out in a voltage-free state and DANGER by authorized and trained electricians! Ensure a voltage-free condition by releasing the fuse in the safety box, secure before restarting! Switch off the device on all poles! Leaky refrigerant...
  • Page 28: Decommissioning

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Decommissioning 15.1 Preparation When decommissioning the outdoor air evaporator unit, first ensure that the heat pump is turned OFF. Next, the heat pump system must be disconnected from the main power supply.
  • Page 29: Disposal

    Disposal When disposing of the outdoor air evaporator or parts belonging to the unit, observe all local-/ national and EU regulation and environmental requirement guidelines regarding disposal and recycling instructions and regulations. These observations are particularly important when disposing of the refrigerant and re- frigerant oil.
  • Page 30: Spare Parts And Accessories

    Fan - Silent Source 80 VT-0002-00 Fan - Silent Source 120 SP-060-07 Side panel Side panel with glass top for Silent Source 60 red SP-060-06 Side panel Side panel with glass top for Silent Source 60 silver SP-080-07 Side panel...
  • Page 31: Technical Data

    Technical data 18.1 Unit data Parameters Unit Silent Source 60 Silent Source 80 Silent Source 120 Unit dimensions 1070 x 890 x 850 1.260 x 1.020 x 960 1.506 x 1.050 x 1.140 height x width x depth Package- dimensions 1.350 x 1.200 x 1.200...
  • Page 32: Contact And Service

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 Contact and Service HELIOTHERM Wärmepumpentechnik Ges.m.b.H Sportplatzweg 18 6336 Langkampfen Austria Tel. +43 (0)5332 87496-0 Fax +43 (0)5332 87496-30 info@heliotherm.com www.heliotherm.com Appendix 20.1 Plans / Drawings / Schemes 27.08.2020 Version 4.0...
  • Page 33: Dimensioned Drawing Silent Source 60

    20.1.1 Dimensioned drawing Silent Source 60 Version 4.0 27.08.2020...
  • Page 34: Dimensioned Drawing Silent Source 80

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 20.1.2 Dimensioned drawing Silent Source 80 27.08.2020 Version 4.0...
  • Page 35: Dimensioned Drawing Silent Source 120

    20.1.3 Dimensioned drawing Silent Source 120 Version 4.0 27.08.2020...
  • Page 36: Dimensional Drawing Aluminium Shaft For Silent Source 60

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 20.1.4 Dimensional drawing aluminium shaft for Silent Source 60 27.08.2020 Version 4.0...
  • Page 37: Dimensional Drawing Aluminium Shaft For Silent Source 80 / 120

    20.1.5 Dimensional drawing aluminium shaft for Silent Source 80 / 120 Version 4.0 27.08.2020...
  • Page 38: Shaft Plan Silent Source 60

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 20.1.6 Shaft plan Silent Source 60 27.08.2020 Version 4.0...
  • Page 39: Shaft Plan Silent Source 80

    20.1.7 Shaft plan Silent Source 80 Version 4.0 27.08.2020...
  • Page 40: Shaft Plan Silent Source 120

    INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 20.1.8 Shaft plan Silent Source 120 27.08.2020 Version 4.0...
  • Page 41: Notes

    Notes Version 4.0 27.08.2020...
  • Page 42 INSTALLATION INSTRUCTIONS Silent Source 60 / 80 / 120 27.08.2020 Version 4.0...
  • Page 43 Version 4.0 27.08.2020...
  • Page 44 © Heliotherm Wärmepumpentechnik Ges.m.b.H. Sportplatzweg 18 I 6336 Langkampfen I Austria Tel. +43 (0)5332 87496-0 I Fax +43 (0)5332 87496-30 info@heliotherm.com I www.heliotherm.com...

This manual is also suitable for:

Silent source 80Silent source 120