SDC UR-1 Installation Instructions Manual

Universal relay module

Advertisement

Quick Links

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
UR-1 UNIVERSAL
RELAY MODULE
J1
C NO C NO - NO C NC - NO C NC
TRIG A TRIG B
FEATURES AND BENEFITS
Microprocessor based relay controller that provides
multiple, field selectable operational modes for up to
two door stations.
Each output relay is field selectable as a dry contact
or voltage output.
Centralized wiring for all locks, access controls,
monitoring contacts and peripheral equipment.
1 or 2 controllers may be installed in SDC 600 series
power supplies
UR-1 TECHNICAL SPECIFICATIONS
INPUT VOLTAGE
INPUT CONTROLLER CURRENT
INPUTS
OUTPUTS
DIMENSIONS
P:\INSTALLATION INST\POWER SUPPLY\INST-UR-1.vsd
INSTALLATION INSTRUCTIONS - MODEL UR-1
UNIVERSAL RELAY MODULE
UR-1
w
w
A
B
D
D
- +
PWR
RELAY A
RELAY B
12 or 24VDC +/- 10%
120/175mA
2 ea Dry Signal Inputs
2 ea 10 amp @ 30VDC (resistive) SPDT Lock Outputs
(Configurable Wet or Dry). Wet output voltage is the
same as the module power IN voltage.
3.20"W x 2.00" L x 1.0" H
[81.28mm W x 50.8mm L x 25.4mm H]
Rev J
06-19
Page 1
UR-1
w
w
A
B
D
D
- +
PWR
J1
- NO C NC
C NO C NO
- NO C NC
TRIG A TRIG B
RELAY A
RELAY B
Fits all SDC Power Supplies. Requires
1 Module space. Supplied with mounting
screws and standoffs for J-box mounting.
Field selectable relay modes include:
- Conventional Relay (CR)
- Dual Conventional Relay (2X CR)
- Time Delay Relay (TD) – 1 to 60 Seconds
- Dual Time Delay Relay (2X TD)
- Latching Relay (LR) – Separate Latch and Release Inputs
- Dual Latching Relay – (2X LR) Pulse On, Pulse Off Inputs
- Time Delay/Latching Relay
- Interlock A (airlock)
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the UR-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SDC UR-1

  • Page 1 Centralized wiring for all locks, access controls, - Time Delay/Latching Relay monitoring contacts and peripheral equipment. - Interlock A (airlock) 1 or 2 controllers may be installed in SDC 600 series power supplies UR-1 TECHNICAL SPECIFICATIONS INPUT VOLTAGE 12 or 24VDC +/- 10%...
  • Page 2 Fail Safe Fail Safe Control Reset Lock Lock Lock Door A Door B Push to Push & Release Fail Secure Fail Secure Fail Secure Activate each to Reset Lock Lock Lock Timer P:\INSTALLATION INST\POWER SUPPLY\INST-UR-1.vsd Rev J 06-19 Page 2...
  • Page 3: Sequencer Mode

    SDC LR100 SERIES After the delay After the delay time time has expired, has expired, The door Fail Secure Fail Secure door B will unlock operator will be Lock Lock signaled to activate. P:\INSTALLATION INST\POWER SUPPLY\INST-UR-1.vsd Rev J 06-19 Page 3...
  • Page 4 Open state Fail Safe with the doors Closed Lock Door B Method of Operation: Both doors are normally closed and Unlocked. Opening either door will Lock the other door. P:\INSTALLATION INST\POWER SUPPLY\INST-UR-1.vsd Rev J 06-19 Page 4...
  • Page 5 When the doors are locked, activating either CB402B Emergency Push Buttons will unlock both the doors. PTH-10 PTH-10 CB402A POWER POWER When used with an SDC 631RF power supply, PUSH ELECTRIFIED ELECTRIFIED TRANSFER TRANSFER Both doors will unlock automatically via signal BUTTON...
  • Page 6 CB401A panel. PUSH BUTTON (INSIDE) When used with an SDC 631RF power supply, Both doors will unlock automatically via signal from the fire panel. Switch No: SW1 SW2 Set to “CR Mode” 12vdc or 24vdc...