PSSU Safety Controllers (Safety Interface Modules)
The PSSU series of safety controllers can be used as safety devices for high-risk automation and machine control
applications. They provide the highest level of safety offered by Tapeswitch, exceeding the requirements of safety
category 3 as defined by EN-954-1f, and meeting or exceeding the safety content of the applicable OSHA, ANSI, and
RIA Standards for safety interface modules..
PSSU safety controllers have redundant safety output relays, are self-monitoring, and are rated Control Reliable, which
means that any fault in the safety-critical components will be detected and the machine will be rendered inoperative
until the fault is corrected.
These safety controllers are designed to be used with Tapeswitch low-voltage sensors such as ribbon switches, safety
mats, sensing edges, or sensing bumpers. PSSU safety interface modules are available in wall-mounted and DIN rail-
mounted versions. Other options include 24 Vdc or 110/220 Vac operation and choice of manual or auto reset.
DIN Rail Mounted
PSSU/1, PSSU/2
Features & Benefits
Suitable for high-risk automation and machine control
•
Self-monitoring design detects faults anywhere in the safety system components
•
Meets or exceeds OSHA, ANSI, & RIA safety standards for safety interface modules
•
Automatic and manual reset versions
•
Wall mounting or DIN rail mounting models
•
Technical Specifications for PSSU Safety Controllers
MODEL
PSSU/1
110/240 VAC
Supply Voltage
50/60 Hz
Mounting
Reset Mode
Output Relay
Output Contact
Rating
Applications
Safety Standard
Wall Mounted
PSSU/3, PSSU/4
PSSU/2
24 VDC
DIN Rail Mounting
Manual (Remote)
2 x Safety Relays (force-guided contacts), Cross-monitored
6 A @ 240 V, Resistive, Non-Inductive
Medium to High Risk Safety (Level of Risk Determined by Sensor)
Up to Level 2: DIN 31006-1, Level 2.2: DIN 31006,
Category 3: prEN 954-1 Control Reliable, Self-monitoring,
(Click on model number to see technical manual)
PSSU/3
PSSU/4
110/240 VAC
24 VDC
50/60 Hz
Wall Mounting
UL and cUL listed
Page 1 of 1
DIN Rail Mounted
PSSU/A, PSSU/A2
PSSU/A
PSSU/A2
110/240 VAC
24 VDC
50/60 Hz
DIN Rail Mounting
Auto Reset