PSSU Safety Controllers (Safety Interface Modules)
The PSSU series of safety controllers can be used as safety devices for high-risk automation and machine control
applications. They provide the highest level of safety offered by Tapeswitch, exceeding the requirements of safety
category 3 as defined by EN-954-1f, and meeting or exceeding the safety content of the applicable OSHA, ANSI, and
RIA Standards for safety interface modules..
PSSU safety controllers have redundant safety output relays, are self-monitoring, and are rated Control Reliable, which
means that any fault in the safety-critical components will be detected and the machine will be rendered inoperative
until the fault is corrected.
These safety controllers are designed to be used with Tapeswitch low-voltage sensors such as ribbon switches, safety
mats, sensing edges, or sensing bumpers. PSSU safety interface modules are available in wall-mounted and DIN rail-
mounted versions. Other options include 24 Vdc or 110/220 Vac operation and choice of manual or auto reset.
DIN Rail Mounted
PSSU/1, PSSU/2
Features & Benefits
Suitable for high-risk automation and machine control
Self-monitoring design detects faults anywhere in the safety system components
Meets or exceeds OSHA, ANSI, & RIA safety standards for safety interface modules
Automatic and manual reset versions
Wall mounting or DIN rail mounting models
Technical Specifications for PSSU Safety Controllers
MODEL
PSSU/1
110/240 VAC
Supply Voltage
50/60 Hz
Mounting
Reset Mode
Output Relay
Output Contact
Rating
Applications
Safety Standard
Wall Mounted
PSSU/3, PSSU/4
PSSU/2
24 VDC
DIN Rail Mounting
Manual (Remote)
2 x Safety Relays (force-guided contacts), Cross-monitored
6 A @ 240 V, Resistive, Non-Inductive
Medium to High Risk Safety (Level of Risk Determined by Sensor)
Up to Level 2: DIN 31006-1, Level 2.2: DIN 31006,
Category 3: prEN 954-1 Control Reliable, Self-monitoring,
(Click on model number to see technical manual)
PSSU/3
PSSU/4
110/240 VAC
24 VDC
50/60 Hz
Wall Mounting
UL and cUL listed
Page 1 of 1
DIN Rail Mounted
PSSU/A, PSSU/A2
PSSU/A
PSSU/A2
110/240 VAC
24 VDC
50/60 Hz
DIN Rail Mounting
Auto Reset

Advertisement

loading
Need help?

Need help?

Do you have a question about the PSSU Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Tapeswitch PSSU Series

  • Page 1 PSSU Safety Controllers (Safety Interface Modules) The PSSU series of safety controllers can be used as safety devices for high-risk automation and machine control applications. They provide the highest level of safety offered by Tapeswitch, exceeding the requirements of safety category 3 as defined by EN-954-1f, and meeting or exceeding the safety content of the applicable OSHA, ANSI, and RIA Standards for safety interface modules..
  • Page 2 The output contacts of the safety relays are only closed when the output relays are energized. When the sensor(s) is PSSU control units are designed to be used with Tapeswitch actuated, the 24 Vdc power supply to the output relays is pressure-sensitive sensors, such as ribbon switches, sensing shorted out causing them to de-energize.
  • Page 3 This test input can be provided by connecting a normally open contact in parallel with the reset switch as shown in Figure 10. Figure 3 TAPESWITCH CORPORATION...
  • Page 4 Multiple Mats with 4 Conductor Standard Color Coded Lead Wire - Figure 13 MAT 1 MAT 2 MAT 3 MAT N BLACK YELLOW BLACK YELLOW BLACK YELLOW BLACK WHITE WHITE WHITE YELLOW WHITE NOTE: Maximum Number of Mats Limited to 100 Square Feet TAPESWITCH CORPORATION...

This manual is also suitable for:

Pssu/1Pssu/2Pssu/3Pssu/4Pssu/aPssu/a2