Download Print this page

Hearth and Home Technologies SRV4660-050 Installation Instructions

Advertisement

Quick Links

Models:
SRV4660-050
Propane to Natural Gas Conversion
SRV4660-051
Natural Gas to Propane Conversion
Conversion Kit
SRV4660-050
SRV4660-051
INSTALLER:
Leave this manual with party responsible for use and
operation.
OWNER:
Retain this manual for future reference.
DANGER!
FIRE OR EXPLOSION HAZARD
If you smell gas:
Shut off gas to the appliance.
Extinguish any open flame.
If odor continues, leave the area immediately.
After leaving the area, call your gas supplier or fire
department.
Failure to follow these instructions could result in
fire or explosion, which could cause property dam-
age, personal injury, or death.
WARNING!
This conversion kit shall be installed
by a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes and
requirements of the Authority Having Jurisdiction. If the
information in these instructions is not followed exactly,
a fire, explosion, or production of carbon monoxide may
result causing property damage, personal injury, or loss
of life. The qualified service agency is responsible for
the proper installation of this kit. The installation is not
proper and complete until the operation of the converted
appliance is checked as specified in the manufacturer's
instructions supplied with the kit.
Hearth & Home Technologies • Gas Conversion Instructions for Duzy • 4660-920 Rev. B • 05/24
Used on Duzy Model
RB-18-24PI
RB-30PI
RB-18-24NI
RB-30NI
Installation
Instructions
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the SRV4660-050 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hearth and Home Technologies SRV4660-050

  • Page 1 Installation Instructions Models: SRV4660-050 Propane to Natural Gas Conversion SRV4660-051 Natural Gas to Propane Conversion Conversion Kit Used on Duzy Model RB-18-24PI SRV4660-050 RB-30PI RB-18-24NI SRV4660-051 RB-30NI INSTALLER: Leave this manual with party responsible for use and operation. OWNER: Retain this manual for future reference.
  • Page 2 Before You Start Valve This conversion shall be installed by a qualified service agency. Any damaged valve components should not be installed. Rubber If a valve or regulator has been dropped or appears to Gasket have been modified, the valve or regulator should not be installed.
  • Page 3 Leak Test 5. Adjust the air shutter by loosening the screw securing air shutter. Rotate shutter to the appropriate settings 1. Disconnect green wire attached to the gas valve. for the type of conversion being performed and re- 2. Turn on gas supply and electrical power to the appli- tighten screw.
  • Page 4 Gas Appliance Specifications Fuel Max. Min. Gas Max. Gas Manifold Burner Pilot Model Type Input Supply Supply Pressure Orifice Orifice Shutter 50,000 5.0 in. wc 10.0 in. wc 3.5 in. wc .144 in. RB-18-24NI Natural 0.023 5/16 in. btu/hr (1.24 kPa) (2.49 kPa) (.87 kPa) (3.7 mm)