Do you have a question about the KFM and is the answer not in the manual?
Questions and answers
Summary of Contents for Hydra Kool KFM
Page 1
KFM | KCP INSTALLATION AND OPERATION MANUAL - V0 D OE D OE Compliant...
Page 2
MVP Group LLC 3560 N.W. 56th Street 33309- FT. LAUDERDALE United States of America Telephone: 786-600-4687 Email: sales@mvpgroupcorp.com Website: www.mvpgroupcorp.com...
Page 3
SYMBOLS For your own protection you must use gloves and safety shoes. Equipment performance can be compromised. Damage may include persons. Flammable.
GENERAL WARNINGS The instructions set in this manual should be read before using the appliance. Make sure that this manual it’s always available and on site. The appliance must be handled only by qualified technicians. Maintenance operations must be performed by qualified and authorized technicians.
Page 5
Keep condenser area always free of obstacles. The appliance has automatic defrost. Do not use alternate means of defrosting besides the ones mentioned by the manufacturer. Do not use electrical apparatus inside the refrigerated com- partment other than ones authorized by the manufacturer All maintenance actions must be done with the appliance fully disconnected.
Page 6
Do not use alternate means to defrost. For proper performance respect all maintenance schedules. In order to promote energy efficiency, before closing the store, set lighting to off position, lower the night curtain, and make sure that all doors are closed. The appliance it’s only for temperature maintenance purposes.
Page 7
GENERAL WARNINGS FLAMMABLES Refrigeration system charged with flammable refrigerant. Make sure that personnal are aware that the appliance contains a flammable refrigerant. Maintenance operations must be performed by qualified technicians to handle flammable refrigerants. Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
Page 8
INDEX Symbols 1. Warranty, standards and regulations 1.1. Warranty 1.2. Eu declaration 2. Technical specifications 2.1. Model description 3. Installation 3.1. Unpacking 3.2. Packaging contents 3.3. Damage verification 3.4. Location 3.5. Electrical connections 3.6. Joining/assembly 3.7. Remote systems 4. Marks 4.1.
Page 9
This page has been left blank intentionally.
Page 10
1. WARRANTY, STANDARDS AND REGULATIONS 1.1. WARRANTY The warranty do not cover any damage caused by the unpacking. The warranty does not cover the poor performance by the poor use and installation. The warranty does not cover any acts of negligence. The warranty does not cover non suitable electrical infrastructure.
Page 11
1.2. CONFORMITY The product respects all legal considerations and standards. All safety and sanitary standards are respected and in compliance. UL471- Standard for safety, commercial refrigerators and freezers NSF7- Commercial refrigerators and freezers DOE compliance- ASHRAE 72...
Page 12
2. TECHNICAL SPECIFICATIONS 2.1. MODEL DESCRIPTION KFM series models and KCP models, are open or closed horizontal service over counters refrigerated displays of food products, available in self contained and remote versions. The ventilated cooling system of these series provides balance and temperature maintenance for the 32°F operating range, ideal for self-service and assisted service of any packaged...
MARKING PLATE The marking plate must not be removed or defaced. COMMERCIAL REFRIGERATOR CONFORMS TO UL STANDARD 471 AND NSF STD MVP GROUP CORP. 7 CERTIFIED TO CAN/CSA STD C22.2 NO. 120 For service, please call: (514) 737-9701 www.mvpgroupcorp.com 4004083 120V CIRCUIT EVAP COND...
Page 26
3. INSTALLATION 3.1. UNPACKING All materials must be removed from the installation area, and routed to proper handling centers.
3.2. PACKAGING CONTENTS The package received with your KFM/KCP series model includes the items arranged in the table below. Model Item KFM/KCP Installation and operation manual KFM/KCP EU declaration KFM/KCP Electrical diagram KFM/KCP Exhibition 3.3. DAMAGE VERIFICATION After rigorous inspection, all units leave HYDRA KOOL without any damage or defect.
Page 28
3.4. LOCATION Use a pallet truck to handle the appliance. Do not drag it! All operations necessary for the installation of the appliance must be performed by a qualified technician. This appliance is intended for indoor use only. This appliance must not be exposed to direct or indirect sunlight. Make sure that the temperature and humidity conditions do not exceed the 75,2°F and 55% relative humidity.
The power grid must not have voltage fluctuations greater than 6% (+/-6%). To unplug the appliance completely, unplug it from the wall outlet. Electrical diagram of the KFM/KCP model must be consulted in Annex A. In case of power cable damage the replacement must be done by a qualified and...
Page 30
3.6. JOINING/ASSEMBLY SHELVES AND PRODUCT STOPPERS ASSEMBLY During any installation always use protective equipment. Operations to be performed are dangerous.
Page 33
MULTIPLEXING During any installation always use protective equipment. Operations to be performed are dangerous.
Page 34
Quantity Code Description Image PA-000000387 Bolt DIN 933 - M6 x 80 PA-000000382 Bolt DIN 933 - M6 x 20 PA-000000735 Washer DIN 9021 - M6 PA-000000708 Hex nut DIN 934 - M6 Socket set screw DIN 916 - M6 PA-000000829 x 16 PA-000000426...
Page 43
3.7. REMOTE SYSTEMS To connect remote appliances wiring and refrigeration piping, operations must be carried out. For perfect operation adjustment may be required on the expansion valve and refrigerant amount function of the installation. Hydracooling models come prepared with simplified system for quick connections. All operations must be carried out by a qualified and authorized technician.
Page 44
Label 1 Label 1 ATENÇÃO EQUIPAMENTO SOB PRESSÃO DE AZOTO ATTENTION EQUIPEMENT SOUS PRESSION D'AZOTE CAUTION EQUIPMENT UNDER NITROGEN PRESSURE Prepare sewage for water. E q u i p m e n t f o r r e m o t e A l l e l e c t r i c a l i n s t a l l a t i o n c o m e w i t h...
Page 45
4. MARKS 4.1. SAFETY MARKS Label 2 Label 1 Label 9 Label 3 Label 10 Label 6 Label 8 Label 12 Label 7 Label 11 Label 1 Label 2 ATTENTION CAUTION PIÈCES MOBILES. MOVING PARTS. NE FAIRE PAS DO NOT OPERATE UNIT FONCTIONNER AVEC WITH (PART) REMOVED DES PIÈCES ENLEVER...
Page 46
Label 5 Label 6 -NOTE- -NOTE- CETTE VITRINE TYPE 1 EST CONÇUE CET EQUIPEMENT EST PREVU UNIQUE- POUR FONCTIONNER SELON LES CON- MENT POUR LE STOCKAGE ET EXPOSITION DE DITIONS DU MAGASIN ET NE DOIT DÉPASSER PRODUITS ALIMENTAIRES 75 F AND 55% R.H. EMBALLER Label 7 Label 8...
The presented control panel may differ from the model purchased. Defrost Continuous cycle Program Light On/Off Eletronic controler Power signal Control panel...
Page 51
Before store closing, make sure doors properly closed, night curtain down, lighting off, for better product conservation. The KFM/KCP series is designed for temperature maintenance only. The goods must be at the appropriate temperature for display. The loading must be done evenly and uniformly on the shelves, respecting the load limits.
Page 52
In order to comply with and prevent personal injury, always use protection. Observe the loading limits on the unit. Make sure the shelves are against the perforated back. Ensure the discharge air and intake are not blocked Make sure operating mode suited for the product inside After products going in/out, please keep doors closed...
The appliance has automatic defrost program. Do not use alternate means to force a defrost, beyond the ones on the manual. DEFROST MODEL KFM/KCP 8/8h - 30min The poor control of ambient conditions, bad temperature settings or incorrect loading, may lead the appliance to abnormal operation, and consequent water overproduction exceeding pan capacity.
Page 54
Carel IJ 4.6.1. APP Password Service: 22...
Page 56
5. EXTERIOR AND INTERIOR SURFACES CLEANING During cleaning operations always use protective equipment. All operations must be carried out with the appliance switched off. Do not use cleaning equipment with jets under pressure. MATERIAL PROCEDURE Use cleaned cloth with warm water, neutral Glass detergent.
Page 58
Front acrylic LED driver Damper Ice connect - component E Evaporator pan (electric) Lighting Evaporator pan (PVC) Bottom lighting Tab terminal block Upper lighting Tab terminal block Switch Power cord Switch Compressor electrical box Switch Electric roller shutter switches Switch Compressor Right side panel Condenser...
Page 59
Relay Ceiling assembly Compressor relay Side panel Defrost resistance relay Plinth Defrosting resistance Front plinth Gutter defrosting resistance Side plinth Caster Left side plinth Front kickplate Right side plinth Right side kickplate Rear plinth Left side kickplate Front decorative panel Rear kickplate Back decorative panel Indicator...
6.2. MAINTENANCE PERIODS MATERIAL PROCEDURE Condenser cleaning Every month Evaporator cleaning Every month Drain inspection Every month Evap pan cleaning Every month Parts inspection Every month 6.3. LIGHTING REPLACEMENT During maintenance operations always use protective equipment. All operations must be carried out with the appliance switched off. All operations must be carried out by a qualified and authorized technician.
Page 61
6.4. GRILLES AND PANELS REMOVAL During maintenance operations always use protective equipment. All operations must be carried out with the appliance switched off. All operations must be carried out by a qualified and authorized technician.
6.5. CONDENSER CLEANING During maintenance operations always use protective equipment. All operations must be carried out with the appliance switched off. All operations must be carried out by a qualified and authorized technician. The condenser should be cleaned monthly.
6.6. EVAPORATOR CLEANING During maintenance operations always use protective equipment. All operations must be carried out with the appliance switched off. All operations must be carried out by a qualified and authorized technician. The evaporator should be cleaned monthly.
Page 65
6.7. DRAIN During maintenance operations always use protective equipment. All operations must be carried out with the appliance switched off. All operations must be carried out by a qualified and authorized technician.
Page 66
6.8. SLIDING CONDENSING UNIT During maintenance operations always use protective equipment. All operations must be carried out by a qualified and authorized technician.
6.9. EVAP PAN CLEANING During maintenance operations always use protective equipment. All operations must be carried out with the appliance switched off. All operations must be carried out by a qualified and authorized technician. Evap pan can be hot. Use liquid vacuum, soft detergent and brush for debris removal.
Page 68
6.10. R290 SYSTEM ASSISTANCE During maintenance operations always use protective equipment. All operations must be carried out with the appliance switched off. All operations must be carried out by a qualified and authorized technician. Actions and tooling must be suitable to the operations in a potential explosive environment.
7. TROUBLESHOOTING All operations must be carried out by a qualified and authorized technician. Use only original parts for warranty purposes Spares on the exploded view To evaluate any situation, check for all necessary equipment, namely, thermometers, thermohigrometer, air speed meter, manifolds, light, and refrigeration tools. Doors not closing: Check for leveled floor;...
Page 70
Compressor not starting: Disconnect switch open; Blown fuse; Overload protective tripped; Low charge of refrigerant; Relay defective. Equipment runs constantly: Condenser dirty; Condenser fan malfunction; Temperature and relative humidity too high. Starting relay burns out: Low voltage; High voltage; Compressor short cycles; Incorrect running capacitor;...
Page 71
8. SERVICE This operation must be performed by a qualified technician. Use only original parts for warranty purposes. Spares on the exploded view. Serial Type of Service by Date number and action model Service by...
9. END OF LIFE HYDRA KOOL products are designed and manufactured in accordance with Directive 2012/19/EU on electrical and electronic waste (WEEE). Concerning preservation, protection and improvement of environmental quality, the products HYDRA KOOL must be selectively collected and not confused with household waste.
Need help?
Do you have a question about the KFM and is the answer not in the manual?
Questions and answers