Page 1
HX-DU1021D User Manual HX-DU1021D Radio Modem Configuration Operation Instructions 一、 Instructions for setting up the test environment 1、 Connect the two radio modems to the computer using a USB-to-RS232 cable 2、Open two serial port assistants (one for sending and one for receiving).
Page 2
HX-DU1021D User Manual Power supply range: 9V-36V Configuration switch GND: configuration mode VCC: transparent mode Radio modem Antenna USB-to-RS232 cable Transmitter end Receiver end 二、Radio Configuration Command Instructions All commands end with a line feed (0x0D 0x0A), and setting commands use a space (0x20) to separate the two parameters before and after.
Page 3
HX-DU1021D User Manual Example: TX 868.125000 Echo "PROGRAMMED OK" 2、Command: TX Function: Query the current transmission frequency Example: TX Echo the current transmission frequency "TX XXX.XXXXX", such as "TX 868.125000" 3、Command: RX parameter Function: Set the current receiving frequency Example: RX 868.125000 Echo "PROGRAMMED OK"...
Page 4
HX-DU1021D User Manual Function: Query the transmission power level. Example: PWR, response the current transmission power level "X", such as "H". 9、Command: CHANNEL parameter Function: Set the current channel number, where parameter ranges from 0 to 49. Example: CHANNEL 10, response "PROGRAMMED OK".
Page 5
HX-DU1021D User Manual Function: Turn on or off the frequency adaptive function. The parameter is “ON” or “OFF”. Example: FAUTO ON Echo “PROGRAMMED OK” 14、Command: FAUTO Function: Query whether the frequency adaptation is enabled. Example: FAUTO Echo “FAUTO ON” or “FAUTO OFF”...
Page 6
HX-DU1021D User Manual Function: Query the number of channels for frequency adaptation. Example: SCAN Echo “The number of channels for frequency adaptation is XX”, such as “2” 19、Command: SBAUD parameter Function: Set the serial port baud rate, supporting 9600bps/19200bps/38400bps/57600bps/115200bps. It takes effect immediately after setting.
Page 7
HX-DU1021D User Manual Example: LOCID Echo “The address of the station is LOCID XX”, such as “LOCID 0” 25、Command: DESID parameter Function: Set the local address of the station. The parameter is from 0 to 65535. The receiving station may output data only when the communication destination address in the data is the station address or broadcast address (65535).
Page 8
HX-DU1021D User Manual Example: BOOT Echo “The version number of boot is XXXX.XX.XX” FCC regulatory compliance statement §15.19 Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 9
HX-DU1021D User Manual Testing item, Frequencies, Transmit Power, Modulation Type can be selected on the test script instructions. FCC other Parts, Part 15B Compliance Requirements for Host product manufacturer This modular transmitter is only FCC authorized for the specific rule parts listed on our grant, host product manufacturer is responsible for compliance to any other FCC rules that apply to the host not covered by the modular transmitter grant of certification.