Schick IQ1 Instructions Manual

Schick IQ1 Instructions Manual

Industrial control unit for handpieces and spindles

Advertisement

Quick Links

original
Instructions
Schick GmbH
Version 2024/03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQ1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Schick IQ1

  • Page 1 Instructions Schick GmbH Version 2024/03...
  • Page 2 We are pleased that you have decided in favor of a technically high-quality device from SCHICK and wish you every success with your new IQ1 control device and that you enjoy working with it. We have compiled these operating instructions to familiarize you with your new device and to provide you with the necessary information for operation and maintenance.
  • Page 3: Table Of Contents

    During operation ................. 10 Maintenance and control work ............10 Maintenance and repair work ............. 10 Structural changes ................10 Extension and remodeling ..................10 Scope of delivery ...................... 11 Technical description ....................11 Overview ........................11 D21930 edition 2024/03 IQ1 Instructions 3/20...
  • Page 4 Safety precautions before installation ..........13 Installation ........................13 establish supply .................. 13 functions and operation ................... 14 IQ1 Controller On/Off ....................14 Operating concept and OLED display ................. 14 Operate handpiece and controller ................15 Starting the handpiece ............... 15 Use of multiple handpieces/spindles .......
  • Page 5 About these operating instructions 1 Appendix ........................19 11.1 service address ......................19 11.2 Declaration of Conformity ................... 20 D21930 edition 2024/03 IQ1 Instructions 5/20...
  • Page 6: About These Operating Instructions

    Pay special attention to the chapter 2"General safety regulations 1.1 General This manual is intended to make it easier for you to get to know the IQ1 and to use it for its intended purposes. The operating instructions contain important information on how to operate the IQ1 safely and properly.
  • Page 7: Structure Of The Warnings

    This sign indicates activities where there is a risk of electric shock, possibly with fatal consequences. hand injuries This symbol stands in front of activities where there is a risk of hand injuries. 7/20 Edition 2024/03 IQ1 Instructions...
  • Page 8: General Safety Regulations

    It is operated manually: either with a rotary knob or a foot pedal. 2.2 Intended Use The IQ1 systems are intended exclusively for universal use in commercial operations for processing solid materials. Only tools intended for processing such materials may be used.
  • Page 9: Safety Devices

    2.7 Protective measures Do not wear long hair loose. Always use suction. Personal protective equipment safety goggles extraction at the workplace. 2.8 Safety regulations General information Caution! Risk of injury from pointed and/or rotating tools! 9/20 Edition 2024/03 IQ1 Instructions...
  • Page 10: While Transporting

    Setting, teach-in only by trained personnel with specialist knowledge of the respective device class. Structural changes Structural changes to the product are not permitted. 2.9 Extension and remodeling An optional dynamic foot pedal and foot pedal on/off switch are available for the IQ1. 10/20 D21930 edition 2024/03 IQ1 Instructions...
  • Page 11: Scope Of Delivery

    Up to three handpieces can be connected, which can be used alternately. Spindles for use in the machine tool can also be connected and operated on the IQ1 control unit. 4.2 Interfaces The IQ1 controllers have the following interfaces to other machines: Connection for controlling suction systems.
  • Page 12: Type Label

    If damage to the packaging is visible when the goods are handed over, this must be re- ported to the transport company immediately and confirmed in writing. The damage must then be reported to Schick GmbH immediately. Requirements for the installation site Devices that have cooled down considerably must be brought to room temperature before being used.
  • Page 13: Installation And Commissioning

    Signal cable for suction  Connect existing handpieces/spindles to socket M1  Optional: Connect a foot pedal to the foot pedal jack  Plug the mains adapter plug into the power supply socket on the control unit. 13/20 Edition 2024/03 IQ1 Instructions...
  • Page 14: Functions And Operation

    The IQ1 control unit may only be switched off using the main switch when the handpiece is stationary. 7.2 Operating concept and OLED display After switching on, the OLED display of the IQ1 control unit provides information about all operating states of the device. The following parameters are displayed in detail:...
  • Page 15: Operate Handpiece And Controller

    7.4 Changing the direction of rotation of the handpiece The IQ1 handpiece can be switched from right to left rotation. The default direction of ro- tation is clockwise. Changing the direction of rotation:...
  • Page 16: Troubleshooting

     Changing the direction of rotation is acknowledged by a vibration signal on the handpiece. If a handpiece on the IQ1 control is subject to greater stress in anticlockwise rotation, the collet can theoretically come loose. Troubleshooting 8.1 Procedure in the event of malfunctions or errors...
  • Page 17: Maintenance And Control Work For Operators

    Allow control unit to cool down. too high. Maintenance and control work for operators 9.1 General information Dirt on the plastic surfaces can be removed with a dry cloth. Do not use harsh cleaning agents! 17/20 Edition 2024/03 IQ1 Instructions...
  • Page 18: Technical Specifications

    10 Technical specifications Dimensions 200 – 50,000 rpm or speed range 1000 – 100,000 rpm Drive system Brushless DC motor Broad 106mm Height 200mm Depth 207mm Weight 2800g Operating voltage 100-240 volts Power consumption 220 watts 18/20 D21930 edition 2024/03 IQ1 Instructions...
  • Page 19 Fax: +49 7356 950095 Email: info@schick-industrie.de Internet:www.schick-industrie.de If service is required, please send your device directly to Schick GmbH at the above address with a precise description of the error. Schick GmbH reserves the right to change this documentation and the de- scriptions, dimensions and technical data contained therein without prior notice.
  • Page 20 At this point we would also like to point out that a corresponding one for such technically high- quality devices Repair service and specially trained specialists is required. SCHICK guarantees you perfect repairs with original spare parts.