Failure to comply with a caution statement may lead to minor or moderate physical injuries. NOTICE Failure to comply with a notice may lead to damage to equipment or may compromise reliable operation of the instrument. SPD01 manual v2404 2/25...
Contents Cautionary statements Contents List of symbols Introduction Ordering and checking at delivery Ordering SPD01 Included items Specifications of SPD01 General overview Rated operating conditions Electrical specifications Weight and dimensions Optional accessories Installation of SPD01 Wiring Diagram Gland connections Earth ground...
List of symbols Quantities Symbol Unit Not applicable Subscripts Not applicable Acronyms International Electrotechnical Commission SPD01 manual v2404 4/25...
Introduction Give your pyranometers the protection they deserve! SPD01 is a surge protection device for digital pyranometers communicating over RS-485. The SPD01 reduces the risk of costly instrument damage and data loss, by serving as an additional layer of external protection against high-impulse currents and voltages - surges- for connected devices.
Page 6
Immunity to high impulse voltages and currents - surges SPD01 is a surge protection device for pyranometers. It is designed for use with the Hukseflux-brand “industrial pyranometer” series of instruments. The device combines and coordinates the protection of the power supply and the RS-485 serial communication lines.
Page 7
• SPD01, sacrificial device SPD01 is built to last. It will survive multiple surges. It is a sacrificial device. In case SPD01 the most likely failure mode is: - that communication with the protected pyranometers through the SPD01 is no longer...
Page 8
2 (LPZ2) as defined in IEC 62305-4:2010 section 4.3. At each zone boundary an SPD of the correct type should be installed. This is indicated in Figure 0.2. For example, the Hukseflux SPD01 is a type 2 SPD which is used on the zone boundary from LPZ0b to LPZ2.
10 m * ‘-20’ after SPD01 part number cable length: 20 m * *for use on the unprotected side of SPD01. Do not use it to connect instruments to SPD01. 1.2 Included items Arriving at the customer, the delivery should include: •...
2 Specifications of SPD01 2.1 General overview SPD01 is a surge protection device intended for use with Hukseflux industrial pyranometers. When properly installed, SPD01 can be used to increase the EN- IEC 61000-4-5:2014+A1:2017 surge immunity to level 4. 2.2 Rated operating conditions...
M12 (protected) Cable diameter 3 to 6 mm Optional SMF01: rated pole mount 40 to 60 mm diameter Weight 0.7 kg Figure 2.4.1 Overview of SPD01: pressure relief vent cable gland earthing terminal gland locking pin SPD01 manual v2404 11/25...
Page 12
Figure 2.4.2 Dimensions of SPD01 in x 10 SPD01 manual v2404 12/25...
Pyranometer insulation disk 2.5.1 SMF01 SMF01 is a practical metal bracket that helps mounting a surge protection device SPD01 on a vertical mast. It comes with mounting screws and two tube clamps (40-60 mm). • tube mounting bracket, with mounting screws •...
Page 14
Figure 2.5.1.2 The SMF01, set of parts. 2.5.2 PID01, electrical isolation Hukseflux industrial pyranometers may be safely installed directly onto a PV array. The electrical potential of the array support structure may be affected by, for example fault currents and lightning strikes. Therefore special care should be taken to potential differences that may be present in different parts of the PV plant installation.
3 Installation of SPD01 3.1 Wiring Diagram SPD01 can be used to protect up to three digital pyranometers and provides a terminal to extend the databus. Five cable glands provide access to the internal screw terminals. The two unprotected screw terminals (and cable glands) are used to connect long (>...
3.2 Gland connections SPD01 is made out of a plastic enclosure with metal cable glands. The metal cable glands are part of the electrical structure of the SPD01 and form an electrical connection between the cable shield and earth ground. The cable shield should be connected to the cable gland housing.
Page 17
Connect the earthing terminal to earth ground to guarantee personal safety When Hukseflux industrial pyranometers and SPD01 are directly connected to a SCADA system the earthing terminal of the pyranometer and SPD01 should be connected to earth as well as the SCADA system enclosure earth ground to realise equipotential bonding.
The optional mounting fixture, for simplified mounting of SPD01 on a pole or tube, is easy to use. It can be fitted to SPD01 using the mount’s M4 bolts and a 4 mm hex key. The SMF01 with SPD01 can be clamped on a (40 to 60 mm diameter) tube or pole with the included tube clamps using a flat head screwdriver or a 7 mm hex nut driver.
Alternatively, another SPD with appropriate specifications can be used to protect the • instrument. The length of each cable connecting an instrument to SPD01 should be kept as short • as possible and should never exceed 3 meters (10 ft).
Page 20
Figure 3.5.1.1 Example of single instrument installation. Cabling from SPD01 to the SCADA system can be extended to an arbitrary length not exceeding the maximum length allowed for RS-485 systems, see Figure 3.5.1.2. In practice 100 meters (328 ft) is an economical, safe, and reliable maximum to work with.
Page 21
The cable shield between SPD01 and the SCADA system may or may not be connected, depending on the grounding strategy and the general installation design.
4.2 EU declaration of conformity Hukseflux Thermal Sensors B.V., Delftechpark 31, 2628 XJ, Delft, The Netherlands hereby declare under our sole responsibility that: Product models SPD01 Product type Accessory conform with the following directive(s): 2011/65/EU, EU 2015/863 The Restriction of Hazardous Substances Directive...