CONTROL UNIT 12 V DC
AZUD FBC 209T
Sistema Azud, S.A. Tel. + 34 968 80 84 02  Fax: + 34 968 80 83 02 E-mail:
azud@azud.com www.azud.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FBC 209T and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AZUD FBC 209T

  • Page 1 MASF0178 - 09 USER’S MANUAL Water Filtration Solutions CONTROL UNIT 12 V DC AZUD FBC 209T Sistema Azud, S.A. Tel. + 34 968 80 84 02  Fax: + 34 968 80 83 02 E-mail: azud@azud.com www.azud.com...
  • Page 2 AZUD. AZUD may alter, remove or change the content of this document without any further notice, and shall not assume any responsibility for errors that may appear in this document.
  • Page 3: Table Of Contents

    2.3 Technical Data of the Control Unit 2.4 Types of activation and backflushing cycles 2.5 Working description 3. PROGRAMMING OF AZUD FBC CONTROL UNIT 3.1 Identify the controller firmware version 3.2 Control Unit Site Map 3.3 Change in reaction to the Pressostat 3.4 Enable/Disable Sound...
  • Page 4: Introduction

    US IN THE FOLLOWING NUMBER +34 968808402 OR IN THE E-MAIL azud@azud.com All the control units manufactured in SISTEMA AZUD, S.A are subject to strict quality control tests and are manufactured under a productive process which meets the requirements of the standard ISO 9001/2000.
  • Page 5: Technical Data Of The Control Unit

    Control Unit. The backflush will be activated when you keep pressed for some seconds the key OK. AZUD FBC Control Unit will allow to keep all this options at the same time, or select just some of them.
  • Page 6: Working Description

    Water Filtration Solutions 2.5.- Working Description. AZUD FBC Control Unit integrates all the control, detection and operation elements that allow AZUD HELIX AUTOMATIC filtration equipment to have complete autonomy. All the components are supplied already assembled, with the auxiliary elements that complete the electric and hydraulic system, which turn the Control Unit into an autonomous and automatic system.
  • Page 7: Programming Of Azud Fbc Control Unit

    Water Filtration Solutions 3. Programming of AZUD FBC Control Unit. 3.1. Identify the controller firmware version Identify the controller firmware version To identify the controller firmware version of Filtron 1-10, navigate to SETTINGS screen. To enter in SETTING screen – Hold ENTER button for 3 seconds (Figure 1).
  • Page 8: Control Unit Site Map

    Water Filtration Solutions 3.2. Control Unit Site Map DP ACTUAL Differential DP SET pressure existing in the installation Differential pressure value which will activate a backflushing Activate manual backflushing FLUSH TIME Backflushing time stations FLUSH MODE Time between ENTER backflushing Introduction / stage modification /...
  • Page 9: Change In Reaction To The Pressostat

    Water Filtration Solutions 3.3. Change in reaction to the Pressostat When an element which temporally cancels the backflushes is connected (see section 4.2), old versions of Filtron 1-10 stop the back-flushing cycle when the controller detects Low water pressure (Close contact in the pressostat input).
  • Page 10: Control Unit Information

    Water Filtration Solutions 3.5. Control Unit Information PRE DWELL Anticipation time of the sustaining valve Manual blackflushing Activated Backflushing Canceled (Contact closed Con & G) Backflushing station activated. 3.6. Programming of Control Unit. FLUSH MODE FLUSH TIME DP SET-POINT Differential Time between Backflushing pressure value...
  • Page 11: Control Unit Configuration

    Water Filtration Solutions 3.7.Control Unit configuration. YES: Selection sustaining 3 seconds valve NO: No selection sustaining valve Increase / decrease the PRE DWELL numeric value Anticipation time of the sustaining valve DWELL TIME Time between stations DP DELAY Delay of the differential pressure gauge.
  • Page 12: Anticipation Time Of The Sustaining Valve

    Water Filtration Solutions Following the different parameters to be programmed of your Control Unit will be introduced. AZUD FBC incorporates a standard programming which allow the user to start up the filtration equipment by the first time and being familiar with the programming to be adapted to the particular conditions of your installation.
  • Page 13: Number Of Stations Of The Filtration Equipment

    Water Filtration Solutions 3.13 Number of Stations of the Filtration Equipment The number of station is automatically selected by the control unit, using every available outputs. 3.14 Backflushing activating pressure differential Indicates the pressure drop value set to activate the backflushing. EXAMPLE A RECENTLY INSTALLED SYSTEM which working with a MAXIMUM FLOW, has a 0,1 bar DIFFERENCE of pressure .
  • Page 14: Auxiliary Elements

    Sustaining valve will always be connected to the last output AVAILABLE. AZUD HELIX AUTOMATIC equipment needs a minimum pressure around the blackflushing process. If your installation dont garantee the minimum pressure, We could provide the KIT sustaining valve.
  • Page 15: How To Activate Backflushes By Real Filtration Time

     Screw: increase pressure Recommended pressure according to  Unscrew: decrease pressure the Equipment's Technical Data Sustaining valve kit is an OPTIONAL component for your equipment AZUD RECOMMENDS TO HAVE ALWAYS ACTIVE THE BACKFLUSHING BY TIME OPTION...
  • Page 16: Components And Spare Parts

    Water Filtration Solutions 5. Components and spare parts. NOTE: THE SPARES ARE THE COMPONENTS WITH A CODE. TO THE REQUEST OF OTHER COMPONENTS ASK YOUR DISTRIBUTOR. Please indicate the serial number of the Control Unit to the request of spare parts.
  • Page 17 Water Filtration Solutions COMPONENTS OF AZUD FBC CONTROL UNIT NUMBER CODE DESCRIPTION MATERIAL ------------- PROGRAMMER ------------- ------------- CONTROL UNIT PANEL ------------- ------------- CONTROL UNIT SUPPORT ------------- ------------- CONTROL UNIT SUPPORT PIPE ------------- ------------- M8X10 SCREW ------------- ------------- 3 WAYS TYPE 1 ELECTROVALVE...
  • Page 18: Safety Information

    Water Filtration Solutions 6. Safety Information Preserve this manual so that the user of the Equipment could familiarize with it. Below there are some general instructions for a safe operation of the Equipment. These instructions are not a close list, the user must adopt as many security measures as necessary to guarantee his security.
  • Page 19: Installation Instructions

    Water Filtration Solutions 7. Installation Instructions. 7.1 installation of the Support To assemble the Control Unit support, place the plate tube on the support, and adjust it with fixation screws. To Fix the support to the ground, use adequate sleeper screws depending on the type of ground for the fixing of the support on the ground.
  • Page 20: Electric Circuits

    Water Filtration Solutions RESET AZUD FBC 209T 12 V DC CONTROLLER GRAPHIC CHART 4 BATTERY Closed contact (Con. and G connection): Backflusing canceled. TIPO D 1.5 V 12 V DC Open contact (no connection): Equipment functioning according to programming. OUTPUTS...
  • Page 21 Water Filtration Solutions ELECTRIC CONNECTION INSTALLED ON THE CONTROL UNIT FBC 209T IN THE FACTORY FOR A 12 V DC EQUIPMENT...
  • Page 22 Water Filtration Solutions 209T/1 – 209T/10 INPUTS FUNCTION TYPE ACTIVATION OF BACKFLUSHING BY CONTACT FREE OF DIFFERENTIAL PRESSURE OR EXTERNAL BACKFLUSHING VOLTAGE SIGNAL DISABLE THE CONTROL UNIT TO PROVOKE STOP CONTACT FREE OF BACKFLUSHES BACKFLUSHING VOLTAGE Depending on the station number installed on the control unit, 1 or 2 outputs will be available. For an even number of stations, 2 outputs will be available, for an uneven number of stations, 1 output will be available.
  • Page 23 Water Filtration Solutions 209T/4 OUTPUT FUNCTION TYPE OUT A ACTIVATION STATION Nº1 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT B ACTIVATION STATION Nº2 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT A ACTIVATION STATION Nº3 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT B ACTIVATION STATION Nº4 SOLENOID BACKFLUSHING...
  • Page 24 Water Filtration Solutions 209T/7 OUTPUT FUNCTION TYPE OUT A ACTIVATION STATION Nº1 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT B ACTIVATION STATION Nº2 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT A ACTIVATION STATION Nº3 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT B ACTIVATION STATION Nº4 SOLENOID BACKFLUSHING...
  • Page 25 Water Filtration Solutions 209T/9 OUTPUT FUNCTION TYPE OUT A ACTIVATION STATION Nº1 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT B ACTIVATION STATION Nº2 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT A ACTIVATION STATION Nº3 SOLENOID BACKFLUSHING 12 V DC LACHT TENSION OUT B ACTIVATION STATION Nº4 SOLENOID BACKFLUSHING...
  • Page 26: Maintenance Instructions

    Maintenance Plan. The checking period depends on the operation conditions, characteristics of the water to be filtered, operation hours, ... AZUD recommends a three months period between the different reviews of the components which involve the disassembly of each element. However, this period should be determined by the user according to the unique characteristics of its installation.
  • Page 27: Possible Problems-Causes-Solutions

    Water Filtration Solutions 9. Possible problems-causes-solutions BACKFLUSHES ARE NOT MADE ONE OR MORE STATIONS ANY STATION MAKES DO NOT MAKE THE THE BACKFLUSH BACKFLUSH COMPLETE OR PARTIAL REDUCTION NON-OPERATIVE OF THE FEEDING IN CONTROL UNIT THE COMMAND VERIFY THE MAINS SUPPLY OF THE CONTROL UNIT AND THE FEEDING FUSE*...
  • Page 28 Water Filtration Solutions CONTINUOUS OR TOO FREQUENT BACKFLUSHES ACTIVATE A BACKFLUSH AND CHECK THE PRESSURE IN THE OUTLET MANIFOLD PRESSURE INFERIOR TO THE PRESSURE EQUAL OR SUPERIOR TO THE MINIMUM REQUIRED. See section “Technical Data” See section MINIMUM REQUIRED. “Technical Data” from the Filtration Equipment from the Filtration Equipment Manual Manual PROBLEM IN...
  • Page 29 Water Filtration Solutions WATER IN THE DRAINAGE MANIFOLD CHECK THE CONTROL UNIT SITUATION CONTROL UNIT IN CONTROL UNIT IN FILTRATION PROCESS BACKFLUSH PROCESS Wait until the backflushing cycle is finished VERIFY EACH OF THE COMMAND MICROTUBES WHICH FEED THE HYDRAULIC VALVES CHAMBERS PRESENCE OF THE THERE IS NO FLOW OF...
  • Page 30: Warranty

    Sistema Azud, S.A. and have been directly bought from Sistema Azud, S.A. This warranty is not a consumer or end user warranty and does not extend to anyone other than those trade costumers who purchase directly in Sistema Azud, S.A.
  • Page 31 Equipment SERIAL NUMBER ________________________________ MODEL_________________________________________ YEAR OF MANUFACTURE_________________________ Request your spare parts to: SISTEMA AZUD, S.A. Polígono Industrial Oeste • Avda. de las Américas P. 6/6 30820 ALCANTARILLA – MURCIA- SPAIN Tel. + 34 968 80 84 02 Fax: +34 968 80 83 02 E-mail: azud@azud.com...