  • Page 1 ® Panel PCs FPC 1702 Series NEMA 4 Sealed 17" Panel PCs FPC 1702-C20: 2.0GHz Celeron CPU FPC 1702-P24: 2.4GHz Pentium CPU FPC 1702-P30: 3.0GHz Celeron CPU All models are available with optional touchscreens USER’S MANUAL VER. 1.1 • JAN 2004...
  • Page 5 CyberResearch, Inc. In no event will CyberResearch, Inc. be liable for direct, indirect, special, incidental, or consequential damages arising out of the use of or inability to use the product or documentation, even if advised of the possibility of such damages.
  • Page 6 ® FPC 1702 Series CyberResearch Panel PCs Intentionally Blank ©Copyright 2004 CyberResearch, Inc.
  • Page 7: Table Of Contents

    System Test and Initialization...42 Award BIOS Setup ...43 Standard CMOS Features ...46 Advanced BIOS Features...47 Advanced Chipset Features...48 Integrated Peripherals ...49 CyberResearch, Inc. 25 Business Park Drive Branford, CT USA Contents P: (203) 483-8815; F: (203) 483-9024 FPC 1702 www.cyberresearch.com...
  • Page 8 Load FPC 1702 Defaults...52 Set Supervisor/User Password ...55 Save and Exit Setup ...56 Exit Without Saving...57 Limitations ...58 Driver Installation ...59 Installation...60 LAN Driver Installation...62 Card Reader Driver Installation ...63 Touchscreen Driver Installation...63 Limitations ...63 ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 9 ® CyberResearch Panel PCs FPC 1702 CyberResearch, Inc. 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
  • Page 10: General Information

    Chapter General Information...
  • Page 11: Introduction

    ® CyberResearch Panel PCs Introduction FPC 1702 is one of the finest panel PCs in the CyberResearch product line. It features a PGA478 socket that can accommodate Pentium® 4 and Celeron® Processors, supporting FSB up to 400/533MHz. Best performance for multimedia solution CyberResearch’s FPC 1702 also supports DDR DRAM up to...
  • Page 12 ® FPC 1702 CyberResearch Panel PCs performance application. Most of all Pentium® 4 Level processors are suitable for FPC 1702. ©Copyright 2004 CyberResearch, Inc.
  • Page 13 ® CyberResearch Panel PCs FPC 1702 CyberResearch, Inc 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA www.cyberresearch.com...
  • Page 14: Safety

    14. If any of the following situations arises, get the equipment checked by service personnel: a. The power cord or plug is damaged. b. Liquid has penetrated into the equipment. ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 15 – shall comply with the standard IEC 60601-1-1, Safety requirements for medical electrical systems. Equipment not complying with UL 2601-1 shall be kept outside the patient environment, as defined in the standard. CyberResearch, Inc. 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 16: Fcc Safety

    This device complies with Part 15 FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. ©Copyright 2004 CyberResearch, Inc.
  • Page 17: Features

    USB port certification Two free PCI expansion slots Digital I/O (8 in, 8 out as Default, up to 16 in or 16 out) Resistive Touchscreen (Optional) CyberResearch, Inc. 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 18: Specifications

    3.06GHz with FSB 400/533MHz, Hyper-Threading Technology supported 184 pin DIMM x 1, support DDR 200/266/333MHz up to 17” SXGA color TFT LCD Intel® 82562 10/100 Base-T Ethernet controller 3 serial ports: 2 x RS-232, 1 x ©Copyright 2004 CyberResearch, Inc. Panel PCs...
  • Page 19 “disable” front USB port ( USB Port 3 controller ) , the card reader must be forced to disable at same time. Front Panel Mounting CyberResearch, Inc. 25 Business Park Drive Branford, CT USA RS-232/422/485 (COM 4 is reserved for touch screen)
  • Page 20 Card, Memory Stick (PRO) and Smart Media Universal 250W switching power Supply with Active PFC Windows 98SE, Windows 2000, Windows XP (19” x 15.7” x 5.7”) (24.4” x 20.6” x 13.8” ) 17.8KG (39.2 lbs) ©Copyright 2004 CyberResearch, Inc. ® Panel PCs...
  • Page 21: Power Supply

    ® CyberResearch Panel PCs Power Supply AC input 250W (standard offer): 24V DC input: CyberResearch, Inc. 25 Business Park Drive Branford, CT USA Output rating: 250W Input voltage: 100VAC~240VAC@47~63Hz Output voltage: +3.3V@16A, + 5V@25A, +12V@13A, +5VSB@2A, -5V@0.3A, -12V@0.8A Output rating: 300W (Maximum)
  • Page 22: Lcd Specifications

    160 ° (V) 40,000 8-wire, analog resistive 2048 x 2048 >75% 1 million activations Windows 98SE, Windows 2000, Windows XP -20 ℃ ~60 ℃ (-4~140 ℉ ) 10 to 90% @35 ℃ , non-condensing ©Copyright 2004 CyberResearch, Inc. ® CyberResearch Panel PCs...
  • Page 23 ® CyberResearch Panel PCs Vibration Shock CyberResearch, Inc. 25 Business Park Drive Branford, CT USA FPC 1702 1G / 5~500Hz (Random / operation) 15G peak acceleration (11 msec. duration) / operation CE/FCC Class B P: (203) 483-8815; F: (203) 483-9024...
  • Page 24: Dimensions

    ® CyberResearch FPC 1702 Panel PCs Dimension Unit : mm 446.00 402.00 483.00 8.00 137.00 25.00 465.00 36.00 150.00 150.00 FPC 1702 Cutout Size : 449 X 367 ©Copyright 2004 CyberResearch, Inc.
  • Page 25: Hardware Installation

    Chapter Hardware Installation Notice: The Quick Installation Guide is derived from Chapter 2 of user manual. For other chapters further installation instruction s, please refer to the user manual CD -ROM that came with the product.
  • Page 26: Safety Precautions

    Use a grounding wrist strap at all times. Place all electronic components on a static-dissipative surface or in a static-shielded bag when they are not in the chassis ©Copyright 2004 CyberResearch, Inc.
  • Page 27: Locations Of Connectors And Jumpers

    ® CyberResearch Panel PCs Location of Connectors and Jumpers Component Side CyberResearch, Inc. 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
  • Page 28: List Of Jumpers

    The table below shows the function of each jumper in the board: Jumpers Label CyberResearch Function Clear CMOS Audio Out Select COM2 Ring/+5V/+12V Selection COM2 RS-232/422/485 Selection COM2 RS-232/422/485 Selection ATX Power simulate AT Power LCD Voltage Selection ©Copyright 2004 CyberResearch, Inc. ® Panel PCs...
  • Page 29: List Of Connectors

    Option PME Connector CN22 VGA Display Connector CN23 MINI PCI SLOT CN25 Front Panel CN27 ATX Power Connector CN28 ATX Power 12V Connector CyberResearch, Inc. 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
  • Page 30: Setting Jumpers

    If you have any doubts about the best hardware configuration for your application, contact your local distributor or sales representative before you make any change. Generally, you simply need a standard cable to make most connections. CyberResearch Closed Closed 2-3 ©Copyright 2004 CyberResearch, Inc. ® Panel PCs...
  • Page 31: Clear Cmos

    J P 2 Function 1-3, 2-4 W/O Amplifier (Default) 3-5, 4-6 W/ Amplifier COM2 Ring/+5V/+12V Selection (JP3) J P 3 Function +12V Ring (Default) CyberResearch, Inc. 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
  • Page 32: Com2 Rs-232/422/485 Select

    2-3, 5-6, 8-9, 11-12 2-3, 5-6, 8-9, 11-12 ATX Power simulate AT Power (JP6) Function 1-2 ON ATX Power Simulate AT Power 1-2 OFF ATX Standard (Default) CyberResearch J P 5 Function RS-232 (Default) RS-422 RS-485 ©Copyright 2004 CyberResearch, Inc. ® Panel PCs...
  • Page 33: Ide Connector

    DATA6 DATA5 DATA4 DATA3 DATA2 DATA1 DATA0 IO WRITE IO READ IO READY DACK IRQ14 ADDR1 ADDR0 CS#1 CyberResearch, Inc. 25 Business Park Drive Branford, CT USA Signal DATA8 DATA9 DATA10 DATA11 DATA12 DATA13 DATA14 DATA15 UDMA DETECT ADDR2 CS#3 P: (203) 483-8815;...
  • Page 34: Fan Connector

    FPC 1702 Fan Connector (CN8&CN24) Signal FAN SPEED SENSE 10/100Base-Tx Ethernet Connector (CN11) Signal TX­ RX­ Option PME Connector (CN12) Signal +5VSB #PME SMB_CLK ® CyberResearch Signal Signal SMB_DATA ©Copyright 2004 CyberResearch, Inc. Panel PCs...
  • Page 35: Floppy Connector

    ® CyberResearch Panel PCs Floppy Connector (CN13) Signal LPT Port Connector (CN14) Signal STROBE PTD0 CyberResearch, Inc. 25 Business Park Drive Branford, CT USA Signal REDWC INDEX MOTOR A DRIVE SELECT B DRIVE SELECT A MOTOR B STEP WRITE DATA...
  • Page 36: Com1~3 Rs-232/422/485 Serial Port Connector

    COM1~3 RS-232/422/485 Serial Port Connector (CN16) Only COM1 support “Wake on Ring” function. Signa l DCD1 RXD1 TXD1 DTR1 DCD2(422TXD-/485DATA-) RXD2(422TXD+/485DATA+) TXD2 DTR2 DCD3 ® CyberResearch INIT SLIN Signal DSR1 RTS1 CTS1 DSR2 (422RXD+) RTS2 (422RXD-) CTS2 DSR3 ©Copyright 2004 CyberResearch, Inc. Panel PCs...
  • Page 37: Ps2 Keyboard/Mouse Connector (Cn17)

    Panel PCs RXD3 TXD3 DTR3 DCD4 RXD4 TXD4 DTR4 PS2 Keyboard/Mouse Connector (CN17) Signal KB_DATA KB_CLK MS_DATA MS_CLK CyberResearch, Inc. 25 Business Park Drive Branford, CT USA FPC 1702 RTS3 CTS3 DSR4 RTS4 CTS4 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
  • Page 38: Digital I/O Port

    Digital-IN / OUT Digital-IN / OUT Digital-IN / OUT Digital-IN / OUT Digital-IN / OUT Digital-IN / OUT Digital-IN / OUT Digital-IN / OUT Signal I/O Address Setting ©Copyright 2004 CyberResearch, Inc. ® CyberResearch Panel PCs 841H 841H 841H 841H 841H 841H...
  • Page 39 P i n 1 4 P i n 1 5 GPI 27 GPI 26 GPI 25 M S B CyberResearch, Inc. 25 Business Park Drive Branford, CT USA P i n 4 P i n 7 P i n 8...
  • Page 40: Vga Display Connector

    P i n 1 9 P i n 2 0 GPI 24 GPI 23 GPI 22 Signal HSYNC VSYNC Signal +3.3V -12V PS_ON ©Copyright 2004 CyberResearch, Inc. ® Panel PCs P i n 2 1 P i n 2 2 GPI 21 GPI 20...
  • Page 41: Atx Power 12V Connector

    ® CyberResearch Panel PCs POWER OK +5VSB +12V ATX Power 12V Connector (CN28) Signal +12V CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 Signal +12V P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
  • Page 42: Fdd & Cd-Rom Installation

    We will guide through installing the FDD and CD-ROM together. Please see the details below: Step 1: Plug in FDD cable Step 2: Fasten the FDD and CD-ROM together with two brackets on the both sides symmetrically. ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 43 FPC 1702 Step 3: Fasten the transferring bar with a pair of screws on the back of the CD-ROM. Step 4: Plug in CD-ROM Cable CyberResearch, Inc 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
  • Page 44: Hdd Installation

    In the following, we will guide you through installing the HDD. Make sure all parts are provided before you start the installation. Step 1: Lock with the screws as the illustration shown. Step 2: Cover the screws with four pieces of anti-vibration rubber ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 45 Panel PCs FPC 1702 Step 3: Orient the two installation brackets as shown below. Step 4: Install the HDD in the bracket as shown below. CyberResearch, Inc 25 Business Park Drive P: (203) 483-8815; F: (203) 483-9024 Branford, CT USA...
  • Page 46 Step 5: Install the other half of the bracket, then tighten the screws. Step 6: Install the HDD module into the FPC 1702 chassis and plug in the cable. Plug the cable in CyberResearch Fix the HDD module with the screws ©Copyright 2004 CyberResearch, Inc. ® Panel PCs...
  • Page 47: Easy Stand Installation

    Two L-shaped easy stands come with the product. Refer to the following illustration to install it. Fix the L-shaped easy stands with the screws on both sides of the monitor. See the illustration below: CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 *4-M4 Screw P: (203) 483-8815;...
  • Page 48: Panel Mount Kit Installation

    Step 3: Tighten screw until FPC 1702 is snug with panel. Step 4: Repeat procedure with each remaining set of hardware. CyberResearch P a n e l M o u n t i n g ©Copyright 2004 CyberResearch, Inc. ® Panel PCs...
  • Page 49: Waterproof Seal Installation

    FPC 1702. Place the seal behind the monitor set as shown below. Locate the monitor set on the wall. Sponge Wall CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024 www.cyberresearch.com...
  • Page 50: Bios Installation

    Chapter BIOS Installation...
  • Page 51: System Test And Initialization

    You are starting your system for the first time You have changed the hardware attached to your system The CMOS memory has lost power and the configuration CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024...
  • Page 52: Award Bios Setup

    CMOS RAM so that it retains the Setup information when the power is turned off. Entering setup Power on the computer and press <Del> immediately. This will allow you to enter Setup. ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 53 Use this menu to specify your settings for frequency/ voltage control. Load Defaults Use this menu to load the BIOS default values for the minimal/stable performance for your system to operate. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 54 Panel PCs Set Supervisor/User Password Use this menu to set Supervisor/User Passwords. Save and Exit Setup Save CMOS value changes to CMOS and exit setup. Exit Without Saving Abandon all CMOS value changes and exit setup. ©Copyright 2004 CyberResearch, Inc.
  • Page 55: Standard Cmos Features

    Once a field is highlighted, on-line help information is displayed in the right box of the Menu screen. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 56: Advanced Bios Features

    ® CyberResearch FPC 1702 Panel PCs Advanced BIOS Features By choosing the Advanced BIOS Features option from the INITIAL SETUP SCREEN menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values. ©Copyright 2004 CyberResearch, Inc.
  • Page 57: Advanced Chipset Features

    Attention: The LCD signal may be turned off automatically after the VGA driver is installed, please press “Ctrl + Alt + F3” to enable LCD signal again. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024...
  • Page 58: Integrated Peripherals

    ® CyberResearch FPC 1702 Panel PCs Integrated Peripherals By choosing the Integrated Peripherals from the INITIAL SETUP SCREEN menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values. ©Copyright 2004 CyberResearch, Inc.
  • Page 59: Power Management Setup

    Power management Setup By choosing the Power Management Setup from the INITIAL SETUP SCREEN menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 60: Pnp/Pci Configuration

    ® CyberResearch FPC 1702 Panel PCs PnP/PCI configuration By choosing the PnP/PCI configurations from the Initial Setup Screen menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values. ©Copyright 2004 CyberResearch, Inc.
  • Page 61: Pc Health Status

    PC Health Status By choosing the PC Health Status from the Initial Setup Screen menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 62: Frequency/Voltage Control

    ® CyberResearch FPC 1702 Panel PCs Frequency/Voltage control By choosing the Frequency/Voltage Control from the Initial Setup Screen menu, the screen below is displayed. This sample screen contains the manufacturer’ s default values. ©Copyright 2004 CyberResearch, Inc.
  • Page 63: Load Fpc 1702 Defaults

    Load Defaults (Y/N)? Pressing "Y" loads the BIOS default values for the most stable, minimal performance system operations. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024...
  • Page 64: Set Supervisor/User Password

    Setup. Setup Enter a password whenever you enter Setup. NOTE: To clear the password, simply press Enter when asked to enter a password. Then the password function is disabled. ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 65: Save And Exit Setup

    This record is required for the system to operate. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 66: Exit Without Saving

    ® CyberResearch FPC 1702 Panel PCs Exit without saving Selecting this option and pressing <Enter> allows you to exit the Setup program without recording any new value or changing old one. ©Copyright 2004 CyberResearch, Inc.
  • Page 67: Limitations

    USB interface are linked together, when user “disable” front USB port ( USB Port 3 controller ) , the card reader must be forced to disable at same time. CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815;...
  • Page 68: Driver Installation

    Chapter Driver Installation...
  • Page 69: Installation

    Take VGA driver installation under Windows 98 for example, choose the corresponding folder depending on your OS When installing the VGA driver under Windows 98, the CyberResearch, Inc 25 Business Park Drive Branford, CT USA FPC 1702 P: (203) 483-8815; F: (203) 483-9024...
  • Page 70 A driver installation screen will appear, please follow the onscreen instructions to install the driver in sequence and click on the Next button. Notice: In some cases the system will ask you to insert ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 71: Lan Driver Installation

    Click Next and choose a route where you want place the folders on before you click on open. Click Next → Yes → Finish and the window will show you how to finish the installation process. CyberResearch, Inc CyberResearch, Inc. 25 Business Park Drive 25 Business Park Drive...
  • Page 72: Card Reader Driver Installation

    The limitations you may need to notice when you start to install the driver. For the sake of USB4 and USB5 community of linkage, the card reader must be forced to disable when the users “disable” front USB port. ® CyberResearch Panel PCs ©Copyright 2004 CyberResearch, Inc.
  • Page 76: Product Service

    Signal connections and programming are the two most common sources of difficulty. CyberResearch support personnel can help you solve these problems, especially if you are prepared for the call.
  • Page 77 ® FPC 1702 Series CyberResearch Panel PCs Intentionally Blank ©Copyright 2004 CyberResearch, Inc.
  • Page 78: Warranty Notice

    CyberResearch, Inc. will, at its option, repair or replace the defective item under the terms of this warranty, subject to the provisions and specific exclusions listed herein.
  • Page 79 ® FPC 1702 Series CyberResearch Panel PCs Intentionally Blank ©Copyright 2004 CyberResearch, Inc.