INTRODUCTION DISCLAIMER WARNING LABELS SERVICE AND REPAIRS ROSIN PRESS SAFETY PRECAUTIONS GENERAL SAFETY PRECAUTIONS COMPONENTS GET TO KNOW YOUR TRP ROSIN PRESS GETTING STARTED BEFORE OPERATION SAFETY CHECK CONNECT POWER CORD ATTACH HYDRAULIC PUMP UNIT STARTING THE ROSIN PRESS STOPPING THE ROSIN PRESS PID SETTINGS PID STANDARD OPERATIONAL PARAMETERS OPERATION...
INTRODUCTION Congratulations on your selection of the Triminator TRP Rosin Press! We want to help you get the best results from your new rosin press and operate it safely. This manual contains information on how to do that; please read it carefully before you set up and use your rosin press.
WARNING LABELS Your safety and the safety of others are very important. We have provided important safety messages in this manual and on the Triminator TRP. This information alerts you to potential hazards that could hurt you or others. Please read these messages carefully. Of course, it is not practical or possible to warn you about all the hazards associated with operating or maintaining a rosin press.
SERVICE AND REPAIRS Repairs may only be carried out by Eteros Technologies or a designated authorized agent (service technician). Should the need arise, please notify us: Eteros Technologies 6175 South Sandhill Road, Unit 600, Las Vegas, NV 89120 www.eteros.com www.thetriminator.com service@thetriminator.com...
ROSIN PRESS SAFETY PRECAUTIONS IMPORTANT SAFETY INFORMATION Triminator rosin presses are designed to extract essential elements from plants containing resin glands utilizing heat and pressure and from a variety of herbal materials. Other uses could result in injury to the operator or damage to the rosin press and or other property.
OPERATOR RESPONSIBILITY Know how to stop and reverse press action immediately in case of emergency. Understand the use of all rosin press controls. Never permit anyone to operate the rosin press without proper instruction. Do not let children operate the rosin press. GENERAL SAFETY PRECAUTIONS KNOW THE SAFETY INFORMATION Read and become familiar with the entire User Guide.
Page 8
ALWAYS OPERATE DEVICE IN A WELL-VENTILATED AREA Dust generated from certain materials can be a health hazard. Use a dust collection system whenever possible. WEAR A FACE MASK OR DUST MASK This device may produce dust or operate near other dust-producing machines. If dust extraction is not considered, a dust mask must be worn.
GETTING STARTED BEFORE OPERATION Read and understand this manual. Know what the controls do and how to operate them. Familiarize yourself with the rosin press and its operation before you begin using it. Know how to quickly shut off the machine in case of an emergency.
ATTACH HYDRAULIC PUMP UNIT Connect hose from manual, air, or electric hydraulic pump to Rosin Press cylinder. Engage hose fitting by pushing into mating cylinder and turning locking ring to secure. NOTICE Ensure hose tip is fully seated with no threads showing. If it is not fully seated, fluid will not flow to and from the pump, and platens will not move up and down properly.
Page 12
COOL DOWN Allow sufficient time in power off mode for Rosin Press to cool before attempting to move machine. NOTICE Be sure to hold the plug when disconnecting the power cord from the electrical outlet. Do not disconnect by pulling on the power cord. Triminator TRP User Guide...
PID SETTINGS Your press has a PID controller on it, it has a temperature sensor and two heating cartridges per platen. These elements communicate with each other in a permanent closed loop controlled by a microcomputer. Your PIDs come preset with Standard Operational Parameters however some users may want to adjust or fine-tune the PIDs further.
PID STANDARD OPERATIONAL PARAMETERS The following settings have been optimized by Triminator engineers to provide the best platen performance. Refer to the PID Manufacturing Settings graph. Follow these settings exactly. NOTICE Make sure your Temp Unit is set to Fahrenheit. Setting Fahrenheit temps in Celsius can result in melting components of the machine.
OPERATION Program optimal press platen temperature into temperature control (PID) units. Typically press operation will be between 195° to 220°F. SET TEMPERATURE 1. Press and hold UP ARROW button for 3 seconds. 2. Press UP or DOWN ARROW until desired temp is shown. 3.
TROUBLESHOOTING THE PID If you find a platen or platens are not functioning properly, you may wish to reset the PID. Some of the most common issues people may have are below. PROBLEM POSSIBLE CAUSE SOLUTION PRESS DOESN'T REACH THE PID parameters set up incorrectly.
Now the PID is unlocked and the parameters can be reset. UNLOCK ADVANCED SETTINGS PID MENU 1. Press and hold SET button for 3 seconds. 2. Press SET button to advance through settings until you get to the screen Loc. 3.
3. Push UP to increase number or DOWN arrow to decrease number until you get to the number 1, then push SET button again until you get to the main screen or allow the screen to timeout to return to the main screen.
This warranty does not apply to cosmetic damage, such as scratches or general wear and tear. Should you experience a technical problem with your equipment, please contact Eteros Technologies at the email or phone number outlined in the Service and Repairs section.
Need help?
Do you have a question about the Triminator TRP ROSIN PRESS and is the answer not in the manual?
Questions and answers