Astraada HMI AS45TFT0403 User Manual

Control touch panel

Advertisement

Quick Links

Control Touch Panel Astraada HMI AS45TFT0403

Table of contents

Introduction ...................................................................................................................................... 1
Changing Modbus communication parameters................................................................................ 1
Main screen ...................................................................................................................................... 1
Grey buttons ..................................................................................................................................... 2
Green buttons ................................................................................................................................... 2
NODE buttons setting screen: ...................................................................................................... 3
NODES SCAN button setting screen: ......................................................................................... 4
Security and logging ........................................................................................................................ 5
History of revisions .......................................................................................................................... 6

Introduction

Version 1.0 of the program supports two models of flowmeters: PEM-500, PEM-1000. It is
compatible since software version 3.0.1005. In previous versions of the flowmeter, it is possible to
use the panel, but only the screen display function will be available, without the ability to control the
screen using buttons.

Changing Modbus communication parameters

According to the factory settings, panel communication is carried out at 115200 bps, NOPA_2s. To
change settings that cannot be entered in the target program, press and hold the upper left corner of
the screen while turning on the device to go directly to the panel settings. The System Loader screen
will be displayed. After pressing the Run button, you will be taken to Panel Setup. Changing the
Modbus RTU transmission parameters will be possible after selecting the Link1 button. Confirm the
changes by pressing the OK button and press the Run button to go to the main program.

Main screen

The panel can be operated using four grey buttons controlling the flowmeter and five green buttons
controlling the modes of device monitoring.
01.A.001/2024.04
USER'S MANUAL
Illustration 1: Main panel view
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HMI AS45TFT0403 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astraada HMI AS45TFT0403

  • Page 1: Table Of Contents

    USER’S MANUAL Control Touch Panel Astraada HMI AS45TFT0403 Table of contents Introduction ............................1 Changing Modbus communication parameters................1 Main screen ............................1 Grey buttons ............................. 2 Green buttons ........................... 2 NODE buttons setting screen: ...................... 3 NODES SCAN button setting screen: ..................4 Security and logging ........................
  • Page 2: Grey Buttons

    The green field of the LCD screen is responsible for displaying the content of the monitored devices' display. There are five messages on it: • “Set nodes pooling rate” – information message about switching to the settings screen of the multi-channel polling mode, described later in the manual.
  • Page 3: Node Buttons Setting Screen

    Appearance: Appearance: NODE buttons setting screen: Illustration 2: View of node address setting screen Each settings screen is labeled. The NODE button settings screen is titled “Set node address”. Field to enter the node address – before logging in to the administrator level, the field will be locked –...
  • Page 4: Nodes Scan Button Setting Screen

    NODES SCAN button setting screen: Illustration 3: View of the device scan time settings screen The NODES SCAN button settings screen is titled “Scan speed setting”. Time value entry field – entry of the polling time value of one address in the monitoring mode for all devices.
  • Page 5: Security And Logging

    Security and logging Illustration 4: The appearance of the login footer In order to protect the possibility of changing the panel's operating parameters, individual fields have been protected with an administrator password. The default administrator password is “1111”. The user level is not password protected. The following fields are protected: •...
  • Page 6: History Of Revisions

    Illustration 6: Password change keyboard The entered password must be confirmed by the enter button, after which the password confirmation screen will be displayed. Please re-enter the new password and press the OK button with a green mark. Illustration 7: New password confirmation screen From now on, the newly set password will apply.