Download Print this page

Daktronics DMP-8122 Installation Quick Manual

Hide thumbs Also See for DMP-8122:

Advertisement

Quick Links

DMP-8122 Installation Quick Guide
Required Parts
Wi-Fi Installation
DMP-8122
Power Supply (with power cord)
Screw Kit and Mounting Hardware
Antenna @ 2
Mounting Bracket
HDMI Cable (ordered through Daktronics or provided by
customer)
Serial Cable (ordered through Daktronics or provided by
customer)
Note: A USB keyboard and mouse are required for Wi-Fi configuration
Hard-wired Installation
DMP-8122
Power Supply (with power cord)
Screw Kit and Mounting Hardware (drywall screws are NOT included)
Antenna @ 2
Mounting Bracket
HDMI Cable (ordered through Daktronics or provided by customer)
Ethernet Cable (ordered through Daktronics or provided by customer)
Serial Cable (ordered through Daktronics or provided by customer)
Standard Installation
DMP-8122 Mounting
The DMP-8122 can be attached to the VESA bracket or the rack shelf. The VESA bracket can be
mounted to different surfaces via direct screw holes, while the rack shelf attaches to a standard rack.
VESA Bracket Mounting
1. Secure the VESA bracket directly to the desired
surface using the eight screw holes and drywall
screws. Refer to Figure 2.
Note: The VESA bracket mount will indicate the
correct orientation with a UP arrow. Make
sure when mounting the VESA bracket
that the arrow points up. Refer to Figure 2.
DD4945520
Rev 08
02 May 2024
Figure 2: Mounting Bracket
201 Daktronics Drive Brookings, SD 57006
www.daktronics.com/support
800.325.8766
Page 1 of 11
Figure 1: Unboxed Components

Advertisement

loading
Need help?

Need help?

Do you have a question about the DMP-8122 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daktronics DMP-8122

  • Page 1 Standard Installation DMP-8122 Mounting The DMP-8122 can be attached to the VESA bracket or the rack shelf. The VESA bracket can be mounted to different surfaces via direct screw holes, while the rack shelf attaches to a standard rack. VESA Bracket Mounting 1.
  • Page 2 2. Align the player’s keyhole screws with the two keyholes on the bracket and slide the player down to secure it. Note: The DMP-8122 will attach to the VESA bracket either facing up or down. Both orientations work. 3. Follow Steps 2-9 from the DMP-8122 Setup (p.2) section to complete setup.
  • Page 3 Drawings & General Diagrams for detail of displays connected in series. 9. Plug the power supply cable into the power port on the DMP-8122. Refer to Figure 5. 10. Connect Ethernet cable to the Ethernet port if performing a hardwire installation.
  • Page 4: Configuration And Troubleshooting

    3. No login is required when accessing the web page from the player. 4. Navigate to Config Profiles. Refer to Figure 9. 5. Select the desired configuration for both outputs from the available options. Figure 9: Config Profiles DD4945520 201 Daktronics Drive Brookings, SD 57006 Rev 08 www.daktronics.com/support 02 May 2024 800.325.8766...
  • Page 5 6. Select Adjust Sign Size once the correct information has been entered. 7. Record the Total Width and Total Height values from the bottom of the section for use in Venus Display Configuration. 8. Select Save. DD4945520 201 Daktronics Drive Brookings, SD 57006 Rev 08 www.daktronics.com/support 02 May 2024 800.325.8766...
  • Page 6 8. Change the setting from [Block Boot] to [Countdown]. Refer to Figure 12. 9. Press the F10 key on the keyboard and select Yes to save configuration and exit. Refer to Figure 13. DD4945520 201 Daktronics Drive Brookings, SD 57006 Rev 08 www.daktronics.com/support 02 May 2024 800.325.8766...
  • Page 7 Set the Intel Graphics Settings Note: Only perform these steps if using more than a single display. 1. Close the DMP-8000 application by opening the Daktronics folder via the Start Menu and selecting DMP8000 Shutdown. 2. Open Intel Graphics Command Center from the Start Menu and accept any license agreements.
  • Page 8 9. Click the Monitor tab and select 60 Hertz from the drop-down menu. Refer to Figure 16. Figure 16: Monitor Tab 10. Click Apply. 11. Reopen the DMP-8000 application by opening the Daktronics folder via the Start Menu and selecting DMP8000. Log in to Venus Control Suite Before first-time login, ensure that the Venus computer uses either the Chrome browser or Internet Explorer (version 11 or later) browser.
  • Page 9: Connecting A Display

    7. Enter the six digit registration code. Refer to Figure 20. 8. Click 9. Confirm the changes. Figure 18: Display Configuration Figure 19: Add a Device Figure 20: Enter Registration Code DD4945520 201 Daktronics Drive Brookings, SD 57006 Rev 08 www.daktronics.com/support 02 May 2024 800.325.8766...
  • Page 10 DMP-8122 Installation Quick Guide Daktronics Network Configuration For a digital display system to communicate with Daktronics cloud-based service and support offerings, system firewalls must be configured to allow traffic from the below-listed IP addresses and ports. IP Addresses and Ports Necessary to Communicate with the Venus Control Suite ®...
  • Page 11: Supplementary Documentation

    Supplementary Documentation Display Control App Quick Guide - DD4948224 Riser Diagrams - LCD Networks: Shop and Layout Drawings Daktronics LCD Networks Resources Page - Use QR code below DD4945520 201 Daktronics Drive Brookings, SD 57006 Rev 08 www.daktronics.com/support 02 May 2024...