  • Page 1 GPM GY series programmer & monitor Manual...
  • Page 2: Table Of Contents

    Contents OUTLINE ......................... 3 ....................3 UTLINE OF FUNCTION ......................3 ACH PART NAME CONNECTION......................... 4 ................... 4 DRIVER INSTALLATION 2.1.1 Manual installation of the driver ................. 6 GPM ..7 ISABLING DRIVER SIGNING CHECK BEFORE INSTALLING DRIVER OF 2.2.1 Outline ........................
  • Page 3: Outline

    Outline 1.1 Outline of function GPM is a tool that does the adjustment and the monitor of the GY sensor and the controller from the personal computer. Correspondence product (As of 2021/10. ) GYHC controller GYDC-05 / GYDC-S1 controller GYSE series probe GYLC controller GYKS2 probe GYMRA probe...
  • Page 4: Connection

    Connection Figure1 GPM connection outline 2.1 The GPM driver installation The main body of GPM and PC used are connected with the USB cable of the attachment. The driver file is included under CDROM/GPMDriver/ First you connect GPM to your PC, this window is shown.
  • Page 5 Select "Install from a list or specific location (Advanced)" as shown in Figure below and then click "Next" Select "Search for the best driver in these locations". The driver is included in CDROM/GPMDriver/ folder. Please enter the file path in the combo-box ("C:\CDM 2.02.04" in figure below) or browse to it by clicking the browse button.
  • Page 6: Manual Installation Of The Driver

    If Windows XP is configured to warn when unsigned (non-WHQL certified) drivers are about to be installed, the message dialogue shown in Figure 2.10 will be displayed unless installing a Microsoft WHQL certified driver. Click on "Continue Anyway" to continue with the installation. If Windows XP is configured to ignore file signature warnings, no message will appear.
  • Page 7: Disabling Driver Signing Check Before Installing Usb Driver Of Gpm

    2.2 Disabling driver signing check before installing USB driver of GPM 2.2.1 Outline In the 64 bit version of Windows® 8 or 8.1, unlike previous versions, Windows imposes strict limitations on driver signing. To install USB driver of GPM, it is required to disable this check temporally.
  • Page 8 Click “More PC Settings”. In Windows8, click “Restart Now” button under advanced setup. In Windows 8.1, “Restart now” button is moved to “PC Setting -> Update & Recovery -> Recovery” After restarting, click “Troubleshoot”.
  • Page 9 Click “Advanced Options” Click “Startup Settings” Click Restart button...
  • Page 10 Press 7 or F7 to choose Disable driver signature enforcement. 10. Install USB driver. If you install or update again, this procedure must be done again because the settings will return to its original state after restarting.
  • Page 11: Installation Of Gpm

    2.3 Installation of GPM Monitor software GPM is installed from attached CD-ROM. Because the setup program is displayed as shown in the figure below when it puts in the CD-ROM drive of the personal computer that uses CD-ROM, and the GPM folder is double-clicked, "Setup.exe"...
  • Page 12 Please input the folder that installs GPM, and click next. The installation starts when "Next" is clicked. When the installation is completed, an icon is shown on desktop.
  • Page 13: Connection With Power Supply/Sensor

    2.4 Connection with power supply/sensor DC24V is supplied between terminals 1 and 2 as shown in the figure below. Another 20 mA current is required in addition to the current for the sensors. The sensor is connected to terminal number 3-5. The number of sensors that can be connected with GPM at the same time is only one.
  • Page 14 GYDC-S1 GYMA...
  • Page 15 GYSE-A/-Q/-S/GYMRA GYPD/GYPS...
  • Page 16: Start/Adjustment

    Start/adjustment 3.1 Start Please connect GPM and connect PC with GPM and the sensor. (Please do not supply 24V power supply yet.) Double click the Icon of desktop named “GPM” The program starts as shown in the figure below. Please supply 24V power on GPM Information on the connected sensor is monitored.
  • Page 17: Saving And Factory Settings

    3.2 Saving and factory settings The common buttons on the tabs are 'Save to sensor eeprom' and 'Reset to factory settings'. The following are available. Save to sensor Press the button to store the setting in memory. eeprom Even if the power is switched off, the settings are still recorded. Reset to factory Press the button to restore the factory settings.
  • Page 18: Monitor

    3.3 Monitor The left sides of the screen are monitors of a present magnet position and the alarm state, etc. The update cycle is one second. (fixed) Serial number Serial number of product Output The analog output type or the digital output type is shown. Analogue 1ch/2ch Current analog output.
  • Page 19: Analog Adjustment

    3.4 Analog adjustment The 'Analog' tab allows you to change the zero and full point settings of the analogue output. ・Adjustment procedure After connection, turn on the GPM and make sure GYConfig (GPM software) and the sensor are connected. ・To make adjustments or change settings Any changes made to the data are immediately sent to the sensor and reflected, but are not yet stored in the sensor at this time.
  • Page 20: Analog Output Adjustment Procedure

    If you make changes to the data and turn off the power without clicking the "Save Settings to Sensor EEPROM" button, the sensor settings will revert to before the changes were made. 3.4.1 Analog Output Adjustment Procedure For sensors with two channels of analog outputs, the zero/full analog outputs can be changed individually.
  • Page 21 The offset amount is signed. To offset closer to the sensor head, add a minus sign. 8. When you finally want to record the settings, press "Save to sensor EEPROM" ・Zero/Full point position output value adjustment (Only if you want to change the output value.) 9.
  • Page 22: Changing The Alarm Polarity

    Analog adjustments and the digital adjustments shown below are independent. Analog/digital settings must be made separately as necessary. 3.4.2 Changing the alarm polarity In the Common tab, if the Alarm polarity check box is unchecked, the alarm signal is switched on in the event of an error.
  • Page 23: Digital Adjustment

    3.5 Digital adjustment The 'Digital' tab allows you to change the zero and full point settings of the digital output. It also sets the output specifications. 3.5.1 Digital output adjustment procedure The calculation of the digital output of the sensor determines the output data (in um) at the factory-set zero and full scale points in advance, and the distance is divided by the resolution.
  • Page 24: Digital Output Offset Methods

    Zero point set Sets the value at the factory zero point. ・If a value is set for "Digital Zero" the output of the factory zero point will be The value set here will be used. ・If you want to move the magnet and make its position a zero output, move the magnet and then click the 'Set here to Zero' button.
  • Page 25: Change Of Code, Polarity, Etc

    ・To offset the output value to the - side, add the amount (unit: um) you want to offset to the 'Digital zero output' and 'Digital full output' respectively from the original value and input the value. ・After modifying the values, press 'Save to sensor EEPROM'. Offset to + side ...
  • Page 26 The product described to this material doesn't become a specification corresponding to the usage (medical equipment, vehicle, aerospace, and nuclear power control, etc.) in which extremely advanced reliability is required. Please consult our business window beforehand when you examine use to such a usage. In general, an electronic equipment malfunctions or, might break down though tries to improve the quality and reliability by our company.