Page 1
LOW VO LTAG E I GNI TIO N SYST E M 3 0 DC I N STA LL ATION & O P E R ATIO N MA N UA L T O INS TALLE R: Leave this manual with the appliance. T O CONSU MER: Keep this manual for future reference.
Page 2
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. W AR N I N G NEVER leave the Fire Feature unattended. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 3
Keep children and pets away from the Fire Feature at all times. W AR N I N G The Outdoor Plus suggests that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping. Our products should be serviced annually by a professional certified in the US by the National Fireplace Institute (NFI) as Gas Specialists or in Canada by WETT (Wood Energy Technical Training).
• Check to ensure that flexible hoses do not have any cuts and wear that may affect the safety before each use. Only the factory supplied hose and regulator must be used. Use only replacement regulator and hose assem- blies specified by The Outdoor Plus. CHECKING FOR GAS LEAKS: Perform a leak test before each use.
Page 5
• CHECK TO ENSURE THAT THE GAS SUPPLY HOSE DOES NOT COME IN CONTACT WITH ANY HOT SUR- FACE, SHARP OR ROUGH EDGES. DO NOT KINK THE GAS LINE WHEN INSTALLING. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 6
• Do not check for gas leaks with a match or open flame. Apply soapy water at areas marked “X”. Open cylinder valve. If bubble appears, close valve and have LP-Gas service person make needed repairs. Also, check appliance valves and connections to make sure they do not leak before lighting appliance. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 7
• Do not store a spare LP cylinder under or near a barbecue grill or other heat sources. Never fill an LP cylinder beyond 80% full. A fire causing death or serious innury may occur. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
California to cause cancer, and Carbon Monoxide, Lead and Lead Compounds which are known to the state of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
• Coils are encapsulated to protect against moisture. • Pilot has robust flame pattern, wind resistant. • Pilot injectors are stainless steel. • Thermocouple is nickel plated for durability. • The Power Wire connector is waterproof. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
• The Electronic Ignition Valve is designed to automatically close the gas valve and shut down should tempera- tures exceed 175° Fahrenheit. To keep the unit cool, proper ventilation and a heat shield must be provided. • The Outdoor Plus Recommends a Stainless Steel Whistle-Free Flex Hose to eliminate the noise PILOT ASSEMBLY CONNECTIONS We pre-assemble the pilot on top of the burner pan and in that configuration, the pilot line, thermocouple, and igniter lead should be lowered through a hole in the pan prior to connecting to the control box.
Lo c ko ut Fl am e Lo ss : Valve s a nd Ign it e r OF F YE S LED 3 B li nks SH UT DOWN : ALL OFF LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
NO OVERHEAD CONSTRUCTION W AR N I N G Venting is required to dissipate heat and any residual fuel. Failure to provide proper ventilation could result in overheating and or explosion. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
• The Outdoor Plus recommends that the pan lip is recessed on trough (linear). The Outdoor Plus cannot guaran- tee the lip on all of our products will be perfectly flat and will not warp due to heat.
Page 14
2. Connections can be inspected and tested outside the cylinder enclosure 3. Connections, which could be disturbed when installing the cylinder in the enclosure, can be leak tested inside the enclosure LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Ensure you use the Home-Run method for connecting multiple Electronic Ignition Component units. DO NOT DAISY CHAIN these units. Ensure you ordered the right gas type and ignition type for your installation. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
UL certified light switch, pool controller, smart home hub, wireless remote light switch, etc. • Please See Figure 4 on Page 19 for a visual reference on the ignition options. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 17
1/2” and 3/4” - 1” in size, or larger. STEP 7: OPERATION INSTRUCTIONS • Please see Page 27 on Operation Instructions, this section outlines how to operate your Low Voltage fire fea- ture. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 18
F I G U R E 1 F I G U R E 2 F L A R E D F ITTI N G F I G U R E 3 LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 19
I NSTAL LATION IN ST R U C TI ON S F I G U R E 4 F I G U R E 5 LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 20
3. NOTE: Propane cylinder NOT included. Make sure to properly locate the gas hose including locating the hose out of pathways where people may trip over it or in areas where the hose may be subject to accidental damage. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 21
Propane Cylinder NOT included. Please ensure the gas hose is correctly positioned to avoid tripping hazards and accidental damage. F I G U R E 7 F I G U R E 8 LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
These transformers are suitable for direct connection to underwater Pool and Spa lights. • Total of 4 knockouts located on the bottom of the transformerr panel. • Mount the transformer panel at least 1FT (30 cm) above ground. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 23
3. Determine wire gauge needed to deliver necessary power. 4. Connect cable to output tap of transformer given in table. NOTE: The Transformer must be connected to a GFCI Outlet for safety. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Placement of media must NOT cover the pilot assembly. Do not use sand or small media. PI LOT P I LOT CORRE CT IN STAL L AT I ON IN C O RRE CT IN STA L LATI O N LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
W AR N I N G Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
• You can activate multiple fire features at once using one button with the included low voltage transformer, or opt for individual buttons for each feature by getting additional transformers for multiple electronic fire features. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
OVERHEATING: The Fire Feature will automatically close the gas valve if temperatures exceed 175° F inside the valve box to prevent component damage. When the unit cools below 175° F it will automatically restart. To correct overheating, ensure that the enclosure has adequate ventilation. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 29
3.25 seconds HSI Warm Up 5 seconds Trial for Ignition 20 seconds 10 seconds Max Flame Failure Response Inter-Purge 5 seconds 15 seconds Flame Loss Recycles Flame Loss Recycles Delay None LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
T HER M O CO U P LE IG NITIO N SYSTEM GAS IN LE T 1 2 V D C IN D C POW E R S UP PLY F U S E 5A LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
1. Ensure air has been bled from gas line. 2. Consult The Outdoor Plus for minimum gas pressure. 3. If natural gas, ensure pilot jet is not for LP. 4. Check pilot injector for clogged jet. Clean or replace.
Page 32
30V DC. If you do have a minimum of 30V DC at the Fire Feature, contact The Outdoor Plus for further assistance. T HE E LE CTR ON I C I G NIT ION VALVE IS TU R NED ON, T HE IGNI TER GLOWS O RA N GE A ND GAS CAN BE H EA RD F LOW ING , BUT DOES N OT IGNIT E: The two most common causes to this fault are;...
Page 33
This is common in a new gas line. By cycling power you can often dislodge the debris. If cycling power does not rectify the problem, turn the gas off using the manual gas shutoff and contact The Outdoor Plus for further assistance.
• When not in use and after cooling, cover your fire pit with a full length cover. The cover will help protect your fire pit from detrimental effects of weather and environmental pollutants (see your local The Outdoor Plus dealer for details).
RE M OVA L OF D E BR I S • Do NOT perform the maintenance until surfaces of the fire feature are cool to the touch, The Outdoor Plus recommends leaving the fire pit off for at least 1 hour prior to servicing.
M IN I CA PAC I T Y U N I TS TOP- PI 3 9 | # 3 9 Or if i ce STA N DA R D & HI GH CA PACI T Y UNI TS LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
S E RVI CE • The Outdoor Plus recommends that our products be serviced by a professional certified in the US by the National Fireplace Institute (NFI) as NFI Gas Specialists. M I N. 9 6” OV E RH E AD C LEA RA NC E MI N .
N ot Warr an tie d O r n a m e n ts & Me d ia N ot Warr an tie d (du e to dire c t he at ) LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 39
Rem ove t he co v er be for e ope r at ing t o av oid v o i di ng t he wa rra nty. LOW VOLTAGE IGNITION SYSTEM 30DC INSTALLATION & OPERATION MANUAL...
Page 40
701 S DUPONT AVE ONTARIO, CA 91761 (909) 460 - 5579 theoutdoorplus.com...