Page 1
A Venturedyne, Ltd., Company S/SM-Series Environmental Test Chamber Instruction Manual Revision 8: April 29, 2021...
Page 2
Thermotron Industries. All relevant issues have been considered in the preparation of this document. Should you notice an omission or any questionable item in this document, please feel free to contact the Thermotron Product Support group between 8:00 and 4:30 Eastern Standard Time at 616-392-6550.
A guide to the operation instructions ............................B1 Operation safety instructions ............................... B2 Performing a test ....................................B3 Connecting and disconnecting electrical power ........................B5 Using port gloves ....................................B5 What to do if the chamber does not operate ........................B5 Thermotron Industries...
Page 4
Charging the R-404A, R-449A, or R-507 high-stage or single-stage refrigeration system ......... D7 Replacing a circulator fan ................................D8 Section E: Parts Lists and Drawings Recommended spare parts ................................E1 Calling Thermotron for assistance ............................... E1 Returning materials ................................... E2 Parts lists and drawings ..................................Section F: Appendix Glossary ........................................
Directly connect the chamber to a dedicated electrical circuit in accordance with local codes. Do not use an extension cord or power strip to connect the chamber to an electrical outlet. If the supplied power cable is too short, consult Thermotron Industries or a licensed electrician. •...
Page 6
Even when the chamber is off, fans and compressors can ALWAYS start when the primary power is connected. • Do not put the machinery section at an angle of more than 45° without special instructions from Thermotron Industries. Thermotron Industries...
All low-humidity chambers must first be operated in a temperature-only mode to evaporate any water condensation from inside the chamber before low-humidity specifications can be met. • Refer to Section A (Installation) and Section C (Preventive Maintenance) for additional information. Thermotron Industries...
• The floor capacity can be increased to 182 kilograms if your chamber was engineered to include a spreader plate or load bar. • Any load capacity requirements exceeding specifications will require engineering. Thermotron Industries...
1. Temperature uniformity is the standard deviation from the mean measured at either -25°C or +100°C. 2. When operating in temperature/humidity mode, temperature range and ramp rate are reduced. 3. Based on temperature uniformity specifications. 4. Air temperature with an empty chamber. Thermotron Industries...
(duty cycle) of a selected time frame. Refer to the refrigeration schematic, the electrical schematic, and the instrument wiring schematic. Thermotron Industries...
Page 11
• To disable humidity operation and monitoring, clear the Humidity option check box. To disable humidity operation but continue monitoring chamber humidity, select the Humidity option check Thermotron Industries...
Page 12
If the chamber temperature is less than the LLS set point, this low limit switch will disable the LN auxiliary cooling system. For additional information, refer to the Watlow manual in the O.E.M. section of this manual. viii Thermotron Industries...
Installing a purge system cooling system cooling system ........A8 Installing humidity port plugs .............................. A9 Connecting the condenser water supply ......................... A9 Installing refrigeration piping ............................A10 Installing electrical wiring ..............................A10 Starting up a chamber ................................A11 ....................................................................................Thermotron Industries...
This equipment is heavy; use the proper equipment to move it. Do not put strain on pipes or external components. CAUTION: Never tip a refrigeration system more than 45° unless instructed by Thermotron Industries. CAUTION: Use the electrical power supply shown on your chamber’s electrical drawing and serial tag, located above the electrical compartment.
1. Inspect the chamber to see that no damage was done during shipment. If the chamber was damaged, note the damage on the bill of lading and contact the carrier or Thermotron Industries. 2. Remove the plastic wrapping and cut the metal bands holding the chamber to the skid.
3. If your chamber has a solid-state humidity sensor, make sure the DRAIN valve is closed on the vapor generator. 4. Connect your demineralized water supply directly to the humidity water inlet, and adjust the water regulator to 20 psig. 5. Check for leaks. Thermotron Industries...
6. Make sure the valve on top of the demineralizer holder is open. 7. Make sure the DRAIN valve is closed on the vapor generator. 8. Connect your water supply to the demineralizer’s inlet and set the water pressure regulator to 20 psig. 9. Check for leaks. Thermotron Industries...
Make sure the valve on top of the demineralizer holder is open. 6. Make sure the DRAIN valve is closed on the vapor generator. 7. Connect your water supply to the filter assembly and set the water pressure regulator to 20 psig. 8. Check for leaks. Thermotron Industries...
2. Attach an air supply to the inlet. The air must be clean, oil-free, and free of liquid water. The air inlet pressure should be 60-100 psig. 3. While the purge is operating, adjust the flowmeter according to the dryer manual in Section F. Thermotron Industries...
1,000 psig. Include a high-pressure relief valve in the line, and insulate the line. 4. Pressurize the line and check for leaks using a leak-detecting solution. Thermotron Industries...
Flush the line with water to remove any debris. Connect the water supply line to the water inlet. NOTE: Glycol 50/50 mix by mass has a specific heat capacity of about 0.75 BTU/lb °F, thus requiring increased flow rates in same-system comparisons with water. Thermotron Industries...
Run the supply line into the electrical compartment using the connector required by the applicable electrical code. Connect power leads to the disconnect switch terminals and run the ground wire to the ground block on the electrical panel. Thermotron Industries...
If your chamber has a pump-down pressure switch (PDPS), allow the chamber to warm to ambient temperature, and turn on the main power. 6. To perform a test, refer to “Performing a test” in Section B of this manual. Thermotron Industries...
Performing a test ................................B3-B4 Connecting and disconnecting the electrical power ....................B5 Using port gloves ..................................B5 What to do if the chamber does not operate ........................ B5 Programmer/controller manual ..............................Recorder manual ................................CD-ROM ....................................................................................Thermotron Industries...
Page 26
+65°C (+150°F). To remove gloves, pull them to the outside of the test space and insert the port plugs from the inside. CAUTION: Before resetting a safety device, read “What to do if the chamber does not operate” later in this section of the manual. Thermotron Industries...
NOTE: If your chamber is equipped with a Therm-Alarm, the high limit has been set to +30°C at the factory. Thermotron recommends resetting this limit to a more suitable value to prevent Therm-Alarm trips while using your chamber. For additional information, see the Therm-Alarm section of your programmer/controller manual.
Page 28
NOTE: If your chamber is equipped with a Therm-Alarm, the high limit has been set to +30°C at the factory. Thermotron recommends resetting this limit to a more suitable value to prevent Therm-Alarm trips while using your chamber. For additional information, see the Therm-Alarm section of your programmer/controller manual.
Thermotron chambers have safety devices that prevent the chamber from operating when a problem exists. Some commonly used safety devices that can be reset by the operator are explained here. If necessary, call the Thermotron Product Support office at (616) 392-6550 between 8:00 am and 5:30 pm Eastern Standard Time.
Checking the oil level in a compressor ..........................C7 Testing safety switches ................................C7 Checking the R-23 or R-508B charge using a refrigeration gauge manifold ........... C8 Checking the R-404A, R-449A, or R-507 discharge pressure .................. C9 Cleaning your chamber ................................ C10 ....................................................................................Thermotron Industries...
Page 32
Use the main power disconnect switch to disconnect the electrical power from the chamber. If the disconnect switch is supplied by Thermotron, it is located on the electrical compartment door; put this switch in the OFF position to disconnect the electrical power.
Also, check the condenser for signs of rubbing or abrasion on tubing, and make sure the fan blades are tight and the condenser fan motor is bracketed down tightly. Thermotron Industries...
Chamber liner maintenance Suggested frequency: Every week Thermotron typically uses stainless steel for all interior parts of a chamber. To prevent corrosion, please follow these guidelines: • To avoid the buildup of chlorides or any contamination on the interior surfaces of the chamber, clean the chamber liner weekly using mild soap and water and a non-abrasive cloth or plastic scouring pad.
4. Close the drain valve. 5. Reconnect the power to the chamber by turning the disconnect switch to ON. 6. Close the service panel. NOTE: Thermotron recommends you drain, disassemble, inspect, and clean the vapor generator at least once a year. Thermotron Industries...
Thermotron Industries. • If large amounts of oil and water are always present, the dryer could be damaged. Replacement dryers are available from Thermotron Industries. 4. Replace the filter bowl; do not use a wrench to tighten it. Miscellaneous checks WARNING: High voltages that can kill are present.
If the switch is working, it will trip and shut the chamber down when the air temperature reaches the temperature setting on the switch. If the switch is not working, replace it. You can get replacement switches from Thermotron Industries. Thermotron Industries...
Refer to “Charging the R-23 or R-508B refrigeration system” in Section D of this manual. • If the system does not need charging: Remove the hoses. b. Replace the service valve cap. Check the service valve cap for leaks. Close the service panel. Thermotron Industries...
On a water-cooled system, you can adjust the R-404A, R-449A, or R-507 discharge pressure with the condenser’s water valve. The water valve has a marking on top indicating how to lower or raise the pressure. Lowering the pressure raises the flow, and raising the pressure lowers the flow. Thermotron Industries...
1. Wipe using a soft cloth or sponge dampened with a mild soap or detergent. 2. Dry with a soft cloth or chamois. • To clean the surface of the work space, use soap, non-abrasive detergent, or oven cleaner. • To clean the programmer/controller, gently wipe with a damp cloth. Thermotron Industries...
A guide to the service instructions This section contains instructions for some common service procedures; for professional service help, contact the nearest Thermotron field service office. The instructions that are not checked do not apply to your chamber. Safety instructions ..............................i-ii and D2 Resetting safety switches ...............................
Page 42
Section D: Service NOTE: If you need technical assistance troubleshooting problems with your Thermotron environmental test chamber, please contact the Thermotron Technical Liaison office at (616) 392-6550 between 8:00 am and 5:30 pm Eastern Standard Time. Follow all WARNINGS to prevent death or personal injury.
The water level in the recirculation Pump reset recirculation tank lid tank is too low. Therm-Alarms and other optional instruments can also act as safety switches. See the configuration sheet, controller manual, and OEM literature for more information on these instruments. Thermotron Industries...
Tighten the two nuts. NOTE: Make sure that the nuts are tight. Loose nuts can cause a blown heat link. 6. Replace the plenum cover and reattach any control sensors that were removed. 7. Reconnect the electrical power. Thermotron Industries...
R-404A, R-449A, and R-507 cooling properties. • Maintain the R-404A compressor’s head pressure at 220 psig ±10 psig. • Maintain the R-449A compressor’s head pressure at 220 psig ±10 psig. • Maintain the R-507 compressor’s head pressure at 220 psig ±10 psig. Thermotron Industries...
You may also call our field service engineers to recover the refrigerant for you. To arrange to have the procedure done, call the Thermotron Product Support office at (616) 392-6550 between 8:00 am and 5:30 pm Eastern Standard Time.
• Make sure bubbles do not reappear. If they do, add more refrigerant. 5. Check the compressor amperage to make sure the system is not overcharged. If the system is overcharged, the amperage will be higher than normal. Thermotron Industries...
9. Tighten the motor mounting screws. 10. Test again for free movement of the fan blade. Re-adjust the motor’s position if necessary. 11. Reconnect the fan motor wiring and test with power applied to the chamber. Thermotron Industries...
Thermocouples Heating coils Thermostats Limit switches Calling Thermotron for assistance At Thermotron, our telephone staff is trained to match your current needs to the proper person or department. To accomplish this, they need the following information: • Your name •...
NOTE: If the defective part is received within 30 days of the issuance of the RMT number, Thermotron will replace the part under the terms of the warranty at no charge. If the part is received after 30 days, Thermotron will invoice the customer for the full cost of the replacement part.
An opening designed to allow access to the test space. port plug: A piece of insulation material that fits into a chamber port. Thermotron Industries...
Page 52
(t/c): A device used to sense temperature as a function of voltage. transducer: A device that converts information from one medium, such as pressure, to another, such as current. Thermotron Industries...