Page 1
Operation Manual BBAL-105 to 112 Analytical Balance www.biolabscientific.com...
Page 2
Analytical Balance About the Balance Specification Model Range Division Repeatability Linearity Pan Size BBAL-110 220g 0.1mg 0.2mg 0.5mg ø 80mm Features Stainless Steel Pan Super bright LCD display with backlight RS232 Interface Mains adapter supplied as standard Windshield supplied as standard...
Analytical Balance Index 1.0 KNOW YOUR BALANCE............4 2.0 SPECIFICATIONS...............4 3.0 UNPACKING THE BALANCE............5 4.0 CALIBRATION THE BALANCE............5 5.0 LOCATING THE BALANCE............5 6.0 SETTING UP THE BALANCE............6 6.1 ASSEMBLING THE BALANCE............6 6.2 LEVELLING THE BALANCE............6 7.0 OPERATION SETTINGS..............7 7.1 SENSITIVITY SETTING..............7 7.2 SPEED SETTING................7 7.3 WEIGHING UNIT SETTING.............8 7.4 COUNTING FUNCTION..............9...
Analytical Balance 01 KNOW YOUR BALANCE Thank you for selecting the FA(N) Series Analytical Balance. This Instruction Manual will guide you of the installation, accessories, trouble-shooting, after sales service information, general maintenance of the balance, etc. it will also guide you through the various applications.
Analytical Balance Operating +10°C to 40°C temperature Power External Power Adapter as standard (Input Voltage220 V) Supply Net Weight 7.5 kg 03 UNPACKING THE BALANCE Remove the balance from the packing by carefully lifting it out of the box. Inside the box you will find everything needed to start using the balance 04 CALIBRATION THE BALANCE The balance need calibration when it not accurate, the step as: •...
Analytical Balance • Avoid air movement such as from fans or opening doors. Do not place near open windows or air-conditioning vents. • Keep the balance clean. Do not stack material on the balances when they are not in use. 06 SETTING UP THE BALANCE 6.1 ASSEMBLING THE BALANCE •...
Analytical Balance 07 OPERATION SETTINGS 7.1 SENSITIVITY SETTING Keep pressing ON, when”Stab“is shown in the display,. Then operation as blow: ----------Poorest Sensitivity ----------Poor Sensitivity ----------Normal Sensitivity ----------High Sensitivity press →0/T← to save setting 7.2 SPEED SETTING Keep pressing ON, when “speed” will show in the display, ----Highest Speed -----High Speed -----Normal Speed...
Analytical Balance 7. 4 COUNTING FUNCTION There are counting functions in the balance, and you can use this for count the quantity.And please keep the products have the same weight, and the minimum weight must be ≥0.5mg. The details operation as blow: 1.
Analytical Balance 7.5 INTERNAL AUTOCALIBRATION TIME SETTING (Only For BBAL-109 & BBAL-110) Press” ON” until it show “AUTO CAL”,Press “0/T” to enter the automatic calibration time setting, press “ON” to choose the different time: FA-N is internal calibration -------10 minutes automatic calibration...
Analytical Balance 09 DATA OUTPUT Model or a decimal point A space or a decimal point A space or * + or - or a decimal point data Data or a decimal point Data or a decimal point Data or a decimal point Data or a decimal point Data or a decimal point Data or a decimal point...
Need help?
Do you have a question about the BBAL-110 and is the answer not in the manual?
Questions and answers