SECTION 1 - DESCRIPTION System Overview The JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System is a dual channel alerting system that provides up to three different messages. The JA37-002 is setup on a per installation basis using cable CAB-USB-0006, or Configuration Cable JA99-001 and CAB-USB-0002, and downloading the system configuration settings and aural messages into non-volatile devices.
JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System Installation and Operating Manual Specifications 1.4.1 Electrical Specifications Power Input Primary nominal voltage 28 Vdc Secondary nominal voltage 14 Vdc Maximum voltage 30.3 Vdc Minimum voltage 11.0 Vdc Emergency voltage 9.0 Vdc...
1.4.3 Environmental Specifications The JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System has been tested to the environmental conditions listed below. Environmental categories for which TSO compliance has been demonstrated are listed in the Environmental Qualification Form in Appendix B of this manual.
Introduction This section contains unpacking and inspection procedures, installation information, and post-installation checks. Continued Airworthiness Maintenance of the JA37-002 is on condition only. Scheduled inspection and/or periodic maintenance of this unit is not required. Unpacking and Inspecting Equipment Unpack the equipment carefully. Check for shipping damage and report any problems to the relevant carrier. Confirm that the Authorized Release Certificate or Certificate of Conformance is included.
2.4.3 Mechanical Installation The JA37-002 can be mounted in any attitude and location with adequate space for the front panel and sufficient clearance for the connector and wiring harness. It requires no direct cooling. 2.4.4 Post Installation Checks 2.4.4.1...
(ProCS™) – refer to section 2.6. 2.5.2 Message Mute Operation The JA37-002 stops playing all messages if the MESSAGE MUTE input is activated while any MESSAGE TRIGGER input is active and stays muted until the next message trigger event. 2.5.3...
Product Configuration Software ProCS™. Configuration data is sent to the JA37-002 via the J2 connector using the Configuration Cables and a computer running the ProCS™ software. For configuration requirements, see section 2.5.1. For full information on the configuration process, and for installation of ProCS™ on your computer, refer to the ProCS™...
Page 12
JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System Installation and Operating Manual The message trigger activation can be selected as Active Hi, or Active Lo. If the 'Message Trigger Priority' box is checked, the signal Priority will be shown.
Page 13
Play selected audio file Audio Files The JA37-002 is loaded with standard audio signals for each of the three messages, but the audio files window allows these signals to be replaced with other recordings during the configuration process. Selecting 'Open…' will open to the Jac>ProCS folders on the attached computer, but will also allow browsing of any directory accessible...
Page 14
JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System Installation and Operating Manual Saving new Audio Files. Note: This pane will not have the full content shown here if no JA37-002 is connected. When suitable alert messages are listed in the...
Selection) are shown in this section. 2.6.4 Other Configuration Features In the JA37-002 Product Information Window, the model number, serial number and check sum of the JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System can be viewed. Installation Kit The kit required to install this unit is not included with the unit.
Mute Switch/Button If the JA37-002 is playing Alert messages (because an alert input is active), momentary activation of the remote Message Mute switch or button stops all messages from playing until the next message is triggered.
Appendix A - Installation Drawings Introduction The drawings necessary for installation and troubleshooting of the JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System are in this Appendix, as listed below. Note: Fully customized Connector Maps and Interconnects can be created using the ProCS software. Refer to the ProCS™...
See Section 1 of the JA37-002 Installation Manual. Installed in accordance with the JA37-002 Installation Manual, Revision [x], and AC 43.13-2, Chapters 2, and 3. The JA37-002 Installation Manual provides detailed installation instructions and wiring diagrams (Section 2, and Appendices A and B).
Page 27
Refer to the JA37-002 Maintenance Manual. 7. Removal and Replacement Information Refer to Section 2 of this manual - the JA37-002 Installation & Operating Manual. If the unit is removed and reinstalled, a functional check of the equipment should be conducted.
Page 28
JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System Environmental Qualification Form Prepared: Checked: Approved: 05-16-24 06-06-24 Nomenclature Aural Message Generator - 3 Channel - Cabin Briefing System Type/Model/ Part No.: JA37-002 TSO No.: CAN-TSO-C139; FAA TSO-C139 Manufacturer’s Build Configuration: JA37-002 Build Configuration Rev A Manufacturer’s Test Report:...
Page 29
JA37-002 Aural Message Generator - 3 Channel - Cabin Briefing System Environmental Qualification Form CONDITIONS SECTION DESCRIPTION OF TESTS CONDUCTED Explosive Atmosphere Equipment identified as Category X, no test performed Waterproofness 10.0 Equipment identified as Category X, no test performed Fluids Susceptibility 11.0...