Summary of Contents for Sharp NEC LED-RPS-CL-R

  • Page 1 Installation Manual Remote Power Switch LED-RPS-CL-R Release Version 1.32 (May 2024)
  • Page 2 ● Be sure to read the following before using the product to use it correctly and safely. Service & Support Service & Support in Europe Please contact: Sharp NEC Display Solutions Europe GmbH Landshuter Allee 12-14, D-80637 München Phone: + 49 (0) 89/99699-0...
  • Page 3 WARNING Connect the product to the correct voltage. If the product is connected to a voltage other than the Do not apply vibrations or shocks to the product. specified voltage, it may lead to a fire or an electrical shock. Do not install the product to unstable locations or In case of a malfunction (nothing is displayed on locations subject to vibrations.
  • Page 4: Part Names And Functions

    Part Names and Functions   A: LED indicators LED Indicator LED state Explanation AC OUT on ON/OFF AC OUT off Flashing AC OUT will switch after cooldown delay Remote mode REMOTE Local mode Normal operation Fast Flashing Device receives data from RS-485 port STATUS Flashing Temperature error or DC voltage error...
  • Page 5 C: AC connector Pin name Explanation Supply line live ( L ) Supply line neutral ( N ) Connect to LED device live ( L ) Connect to LED device neutral ( N ) Note The protective ground wire (PE) must be connected with a seperate clamp D: RS-485 Termination switch Set the switch to ON, for the first and the last device in the chain For the other devices set the switch to OFF.
  • Page 6: Cable Information

    Cable Information AC connector The following cables can be used. Conductor cross section rigid 1.5 mm to 6 mm Conductor cross section flexible 1.5 mm to 6 mm Stripping length 10 mm Note Press the orange levers, then plug in the cables. To disconnect them, unplug the cables while pressing the orange levers.
  • Page 7: Wiring Diagrams

    Wiring Diagrams RS-485 control Device - 1 Device - 2 Device - 3 ON/OFF ON/OFF ON/OFF REMOTE REMOTE REMOTE STATUS STATUS STATUS MODE MODE MODE from to LED from to LED from to LED POWER BOX Screen POWER BOX Screen POWER BOX Screen (Line 1)
  • Page 8: Mounting On Din Rail

    Mounting On Din Rail Using 35mm DIN rail. Mounting Place the upper keyway hooks onto the top edge of DIN rail. (A) And then, push toward the mounting surface. check that it is attached securely. Removal Use a suitable screwdriver to release the locking mechanism of the device. (B) Carefully lift it off the DIN rail.
  • Page 9: Address Setting

    Address Setting Method for two devices Master(Address=02) Slave(Address=XX Device - 1 Device - 2 ON/OFF ON/OFF REMOTE REMOTE STATUS STATUS MODE MODE Power Supply +12V Procedure: 1. Connect according to diagram above. 2. Switch on the DC Power supply. 3. Press the MODE button of the master device within 10 sec after turning the power on and keep the button pressed for at least 15 sec.
  • Page 10: Communication Protocol

    Communication Protocol Serial settings Baud Rate 19200bps Data 8 bits Stop Bit 1 bit Flow control None Sending (PC LED-RPS-CL-R) Start of Source Destination Command Checksum End of Frame Address (1-byte) Address (1-byte) (1-byte) (2-byte) Frame (1-byte) (2-byte) (2-byte) (1-byte) (*1) (*2) ASCII...
  • Page 11 Command list Sending Function Sending Response command Reception example command example pwr#on Sets AC OUT to on. 01.02.pwr#on.82 No reply No reply pwr#of Sets AC OUT to off. 01.02.pwr#of.7A No reply No reply reqps Requests the state of 01.02.reqps.54 ps:on AC OUT is on.
  • Page 12 Explanations About Operations (1) AC OUT control and operation after turning the devices on 0sec 30sec DC12V AC OUT turns on 30 seconds after the Open(off) devices have been turned on when AC Control in OUT is set to on using Control in or RS- Low(on) ps#on 485 within 30 seconds after turning the...
  • Page 13 0sec 30sec DC12V Open(off) Control in AC OUT turns on immediately when Low(on) AC OUT was turned on more than 30 ps#on ps#of ps#on seconds after AC OUT had been set to RS- 485 on using Control in or RS-485. AC(L) OUT ON/OFF (LED indicator)
  • Page 14: Specifications

    Specifications AC IN Input voltage 100 V AC to 240 V AC Input current Max. 16 A Load capacity Max. 6000 μF DC IN Supply voltage +12 V ± 1.5 V Power consumption 1,3 W (AC OUT on) 0.3 W (AC OUT off) CONTROL RS-485 Control In...
  • Page 15 Dimensions (Unit: mm)