  • Page 1 RENOGY ONE Vision 7 VERSION A0 RSHSN-W02W7-G1 April 8rd, 2024 USER MANUAL...
  • Page 2 Renogy is not responsible or liable for failures, damages, or injuries resulting from repair attempted by unqualified personnel, improper installation, and unsuitable operation.
  • Page 3: Table Of Contents

    1.1. Symbols Used ........................1 1.2. Product Overview ........................1 1.3. Key Features ........................1 1.4. Model Info ..........................1 2. Get to Know Renogy ONE Vision 7 ................2 2.1. What’s In the Box? ......................2 2.2. Product Overview ......................2 2.3. Wiring Diagram ........................3 3.
  • Page 4 9.2. Cleaning ..........................21 9.3. Storage ..........................21 10. Emergency Responses ................... 22 10.1. Fire .............................22 10.2. Flooding ...........................22 10.3. Smell ..........................22 10.4. Noise ..........................22 11. Important Safety Information ................23 11.1. General Safety .........................23 11.2. ONE Vision Safety ......................23 Renogy Support ......................24...
  • Page 5: General Information

    NOTE: Indicates an important step or tip for optimal performance. 1.2. Product Overview Renogy ONE Vision is a centralized power management touch panel specially designed for recreational vehicles and campervans. When working in association with Renogy ONE Core and PMS1280 Distribution Box, ONE Vision visualizes power management and control, allowing you easily to control your power supply devices and appliances.
  • Page 6: Get To Know Renogy One Vision 7

    2. Get to Know Renogy ONE Vision 7 2.1. What’s In the Box? RENOGY ONE Vision 7 VERSION A0 RSHSN-W02W7-G1 April 8rd, 2024 Renogy ONE Vision 7 × 1 USER MANUAL User Manual × 1 Mounting Bracket × 1 KA3*14 mm Mounting Screw ×5...
  • Page 7: Wiring Diagram

    Renogy ONE Core DC Power Source (8V–60V) Router (Optional) Positive Negative Wired Communication The ETHERNET Port is optional because Renogy ONE Vision 7 supports WLAN that allows you to connect to a 2.4 GHz Wi-Fi router wirelessly. — 3 —...
  • Page 8: Preparation

    To ensure quality wireless communication between Renogy ONE Vision and Renogy ONE Core, ensure there is no metal objects near Renogy ONE Vision and keep a maximum distance of 10 m (3.28 ft) between ONE Vision and ONE Core.
  • Page 9 Cut the included power cable using a wire stripper. Strip off some of the insulation. Strip some insulation off the bare wires, and connect them to the included power cable by twisting them together. Acceptable connection methods include heating tubes, junction boxes, and welding.
  • Page 10: Inspect One Vision

    All connector contacts shall be clean and dry, free of dirt and corrosion. Do not use Renogy ONE Vision if there is any damage. 3.4. Check DC Power Inspect the DC power source for any visible damage including cracks, dents, deformation, and other visible abnormalities.
  • Page 11: Install The Mounting Bracket

    The recommended minimum depth for the hole should be 0.79 inches (20 mm). 4.3. Install the Mounting Bracket Step 1: Place the mounting bracket in the installation hole with the bottom facing towards the hole, as shown in the figure below. Step 2: Secure the mounting bracket with the included mounting screws.
  • Page 12: Network Wiring (Optional)

    4.5. Network Wiring (Optional) The ETHERNET Port is optional because Renogy ONE Vision 7 supports WLAN that allows you to connect to a 2.4 GHz Wi-Fi router wirelessly. Recommended Tools & Accessories A RJ45 Ethernet cable shall not exceed 19.6 feet (6 m).
  • Page 13: Operation

    Step 3: Align the upper fixing clips of the ONE Vision with the slots on the upper part of the mounting bracket and insert them vertically Please ensure the ONE Vision is firmly secured to the mounting location to prevent from falling off. 5.
  • Page 14: Networking With Renogy One Core

    Ensure the voltage is no smaller than 8V. 6. Networking with Renogy ONE Core Both Renogy ONE Vision and Renogy ONE Core are integral part of Renogy ONE Family. To ensure data synchronization on ONE Vision and ONE Core, ONE Vision needs to be paired with ONE Core.
  • Page 15: Personal Hotspot Networking

    █ ONE Vision as an Access Point Step 1: On ONE Vision, navigate to “ > Personal Hotspot”, and enable Personal Hotspot. You can check the “Hotspot Name” and “Hotspot Password” of Renogy ONE Vision. Step 2: On ONE Core, go to “...
  • Page 16 Only Renogy ONE Core G2 and later generations support the access point function. Check the silkscreen on the rear side of Renogy ONE Core, and ensure there is G2 and higher generation silkscreen in the SKU. For details, contact Renogy customer service team via renogy.com/contact-us.
  • Page 17: Configuration And Monitoring

    You can configure and monitor the following information on ONE Vision: z My RV z Power Typology z Settings z Alarm & Troubleshooting You can switch to different interfaces in the Menu on the left side of Renogy ONE Vision. My RV Power Topology Settings Alarm &...
  • Page 18: My Rv

    7.1. My RV By default, ONE Vision displays My RV as the home screen where you can check the basic info of as well as operating status of power devices that are connected to Renogy ONE Vision in your RV.
  • Page 19 Renogy ONE Vision automatically displays the currently connected devices in a default layout. You can change the layout by tapping and holding the widgets and then dragging them to the required locations. For details, see Move a Widget. █ Move a Widget Step 1: In the My RV interface, tap and hold a widget to enter Editing Mode.
  • Page 20: Power Typology

    The Power Typology interface allows you to see the current direction going in or out of power supply devices and appliances that are connected to Renogy ONE Vision, helping you easily obtain the operating status of the devices. Supported devices include:...
  • Page 21: Settings

    Language: display language z About: Renogy ONE Vision info z Reset: Reset Renogy ONE Vision to factory mode. z Widgets: smart scene and device widget settings z Ports: DC load, temperature sensor, water level sensor, intelligent ONE Vision port,...
  • Page 22: Alarm & Troubleshooting

    7.4. Alarm & Troubleshooting The Alarm & Troubleshooting interface displays system alarms and relative troubleshooting tips. Renogy ONE Vision provides several types of alarms: Icon Alarm Level III Alarm. Critical alarms that need to be addressed immediately. Otherwise, device damage or human injury may occur.
  • Page 23: Dimensions & Specifications

    8. Dimensions & Specifications 8.1. Dimensions 1.57 in 7.14 in (181.3 mm) (40 mm) 4.66 in (118.3 mm) 4.69 in (119.2 mm) 0.71 in (18 mm) 2.93 in (74.5 mm) Dimension tolerance: ±0.2 in (0.5 mm) — 19 —...
  • Page 24: Technical Specifications

    8.2. Technical Specifications Model Name RSHSN-W02W7-G1 Input Voltage 8-60V DC (Typical 12V DC) Power Consumption 0.5W @12V (Screen Off @Wi-Fi On) Operating System Android 12 Quad-core Cortex-A53 64-bit CPU CPU and Memory Memory: 2GB Storage: 32GB 7-inch touch screen Display Screen Resolution: 600 x 1024p Brightness: 300 cd/m^2 Wi-Fi 2.4 GHz Wi-Fi (IEEE 802.11b/g/n) Bluetooth...
  • Page 25: Maintenance

    Follow the steps below to clean Renogy ONE Vision regularly. z Disconnect all cables connected to Renogy ONE Vision. z Wipe the housing and connector contacts of Renogy ONE Vision with a dry cloth or nonmetallic brush. If it is still dirty, you can use household cleaners.
  • Page 26: Emergency Responses

    CO₂, and ABC dry power. Do not use type D (flammable metal) fire extinguishers. 10.2. Flooding 1. If Renogy ONE Vision is submerged in water, stay away from the water. 2. Disconnect all cables connected to Renogy ONE Vision. 10.3. Smell 1.
  • Page 27: Important Safety Information

    Do not dispose of Renogy ONE Vision as household waste. Comply with local, state, and federal laws and regulations and use recycling channels as required. z If Renogy ONE Vision is installed improperly on a boat, it may cause damage to components of the boat. Have Renogy ONE Vision by a qualified electrician.
  • Page 28: Renogy Support

    To discuss inaccuracies or omissions in this quick guide or user manual, visit or contact us at: renogy.com/support/downloads contentservice@renogy.com Questionnaire Investigation To explore more possibilities of solar systems, visit Renogy Learning Center at: renogy.com/learning-center For technical questions about your product in the U.S., contact the Renogy technical support team through: renogy.com/contact-us 1(909)2877111 For technical support outside the U.S., visit the local website below:...
  • Page 29 FCC Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.
  • Page 30 Save 105 gallons of water from being consumed Renogy Power PLUS Renogy Power Plus allows you to stay in the loop with upcoming solar energy innovations, share your experiences with your solar energy journey, and connect with like-minded people who are changing the world in the Renogy Power Plus community.